MRU-21 Earth Resistance Meter

Availability:

2 in stock


Possible measurements:

  • earth resistance measurment with 3-pole method,
  • measurement of continuity of equipotential bondings and protective conductors with auto-zero function – with current 200 mA,
  • resistance measurement using 2-pole method.

0

2 in stock

Compare

Earth Resistance Meter

Weight 1.4 kg
Dimensions 29 × 22 × 7 cm

Measurement of earthing resistance 
measurement range to IEC61557 – 5:
0,50 Ω…1,99 kΩ for Un=50 V;
0,68 Ω…1,99 kΩ for Un=25 V;

Range Resolution Accuracy
0,00…9,99 Ω 0,01 Ω ±(2% m.v. + 3 digits)
10,0…99,9 Ω 0,1 Ω
100…999 Ω 1 Ω
1,00k…1,99 kΩ 0,01 kΩ

• measurement current: under short circuit >20 mA,
• voltage on open terminals: selectable <25 V AC or <50 V AC,
• frequency of measurement current: 125 Hz

Measurement of interference voltage UN (RMS)

Range Resolution Accuracy
0…100 V 1 V ±(2% m.v. + 3 digits)

• measurement for DC and AC 45…65 Hz

Measurement of resistance of auxiliary electrodes RH i RS

Range Resolution Accuracy
0…999 Ω 1 Ω ±(5% (RS+RE+RH) + 3 digits)
1,00k…9,99 kΩ 0,01 kΩ
10,0k…50,0 kΩ 0,1 kΩ

Measuremet of continuity of equipotential bondings and protective conductors 
measurement range to IEC61557 – 4: 0,13 Ω…199 Ω

Range Resolution Accuracy
0,00…9,99 Ω 0,01 Ω ±(2% m.v. + 3 digits)
10,0…99,9 Ω 0,1 Ω
100…199 Ω 1 Ω
  • measuring method: technical 2-pole method,
  • max. voltage on open terminals: 13 V,
  • measurement current: under short circuit >200 mA,
  • auto-zero function for measurement leads

Electric security:

  • type of insulation: double, according to EN 61010 – 1and IEC 61557
  • measurement category: CAT IV 300 V acc. to EN 61010 – 1
  • protection class acc. to EN 60529: IP54

Rated operational conditions:

  • operation temperature: -10…+55°C
  • storage temperature: -20…+70°C
  • humidity: 20…80%

Other technical data:

  • LCD display: segment, backlit
  • interface: USB,
  • number of measurements carried out of set of batteries: > 1000 (5 Ω, 2 meas./min.)
  • warranty: 2 years
  • dimentions: 288 x 223×75 mm
  • weigth: 1,4 kg

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MRU-21 Earth Resistance Meter”

There are no reviews yet.

  • UT202BT Smart AC Clamp Meter

    0 out of 5
    (0)

    1. Button-design clamp meter
    2. One-hand operation and easy to use
    3. True RMS / 9999 counts
    4. Jaw opening: 28mm
    5. Bluetooth 5.0
    6. 600V DC voltage measurement
    7. 600V AC voltage measurement
    8. 600A AC current measurement
    9. Inrush current measurement
    10. Dual display: V+HZ and A+HZ
    11. Temperature measurement
    12. Low pass filter measurement
    13. Bright backlight / Flashlight
    14. Non-contact voltage (NCV)
    15. CAT III 600V

    SKU: n/a
  • Insulation Resistance Testers UT512

    0 out of 5
    (0)

    UT510 series is a kind of intelligent insulation tester. The device circuit design takes microcomputer technology design as the core and combines the large scale integrated circuit with digit circuit. It is equipped with strong measuring software and data processing software. It is applied to the parameter measurement of insulation resistance, voltage and low resistance. It has stable performance and simple operation. It is applicable to on-site measurement and repair of the electrical equipment and charging line. It is the ideal tool of maintaining electrical equipment. It is also used for smelting, communication, manufacture, fossil oil, national defense, electricity, chemical industry and circuit.

    SKU: n/a
  • UNI-T MSO3254E 250MHz Mixed Signal 4 Channel Digital Oscilloscope

    0 out of 5
    (0)
    Analog bandwidth 150MHz 250MHz
    Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital
    Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels)
    Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels)
    Memory depth 70Mpts
    Waveform capture rate 200,000wfms/s
    Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display )
    Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall]
    Input impedance (1MΩ±1%) II (20pF±3pF)
    Input impedance digital (101kΩ±1%) II (9pF±1pF)
    Vertical scale 1mV/div~20 V/div (1 MΩ)
    DC gain accuracy <5mV: ±3%, ≥5mV: ±2%
    Waveform record 100,000 frames
    Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
    CAN, LIN, FlexRay
    Bus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay
    Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations
     

     

    Auto measurements

    Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
    -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
    channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A
    Measurement display 5 types
    Measurement statistics Average, Max, Min, standard deviation and number of measurements
    Frequency counter 6 bits
    Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA
     

     

    Standard Accessories

    USB interface cable UT-D14
    Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06
    Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05
    16CH Logic analyzer probe UT-15M

     

    SKU: n/a