  • It allows to take the measurements of:

    • earthing resistance using auxiliary electrodes,
    • earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
    • earthing resistance using double clamps for measuring multiple earthing without underground connections.
    • ground resistivity (Wenner method),
    • continuity of equipotential bondings and protective
    • conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.

    Additionally:

    • measurement of resistance of auxiliary electrodes RS and RH,
    • measurement of interference voltage,
    • measurement in the presence of interference voltage in the power network
    • with frequency 50Hz, 60Hz,
    • selection of maximum measuring voltage (25V and 50V),
    • introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
    • memory of 990 measurements (10 banks of 99 cells each),
    • calibration of clamp used,
    • data transmission to the computer (USB),
    • indication of battery state.

0

3 in stock

Compare

The Sonel MRU-30 uses most known methods of earth resistance measurements. Tests can be performed using the 3-pole, 4-pole, 3-pole with auxiliary clamp and also, additionally, the MRU-30 employs the two clamp method of measurement, without the use of auxiliary test rods which can’t be used in some situations. Complementary features of the MRU-30 are measurements of soil resistivity, continuity measurement of protective and equipotential conductors and, using clamps, leakage currents and interference voltages.

  • Robust and weatherproof (IP65) – no ingress of dust, water protected by a nozzle against enclosure from any direction.
  • Ergonomic casing – small and handy casing to make the measurements more convenient than before.
  • Built-in rechargeable battery – saving time to replace flat batteries; can be recharged from Power Bank and Cigarette Lighter Socket!
  • Clear on-screen notes – displayed on screen before and after the measurement to alert user of possible dangers and irregularities.
  • Many measurement methods available in a small, portable casing
Weight 5 kg
Dimensions 20 × 15 × 7 cm

Measurement of interference voltage UN (RMS)

Range Resolution Accuracy
0…100 V 1 V ±(10% m.v. + 1 digit)

Measurement of continuity of equipotential bondings and protective conductors (Rcont)
measurement range to IEC 61557-4:2007: 0,13 Ω…1999 Ω

Range Resolution Accuracy
0,00…9,99 Ω 0,01 Ω ±(2% m.v. + 3 digits)
10,0…99,9 Ω 0,1 Ω
100…1999 Ω 1 Ω

• measurement current: under short circuit >200mA
• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz (for networks 60 Hz)

Measurement of earthing resistance (method 3- and 4-pole)
measurement range to IEC 61557-5:2007: 0,53 Ω…9999 Ω (dla 50 V)

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(3% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200,0…1999 Ω 1 Ω ±5% m.v.
2000…9999 Ω 1 Ω ±8% m.v.

• measurement current: under short circuit >20 mA,
• voltage on open terminals: selectable 25 V AC or 50 V AC,
• frequency of measurement current: 125 Hz (for networks 50 Hz) or 150 Hz (for 60 Hz).

Measurement of multiple earthing esistance with using the clamp and auxiliary electrodes (3p + clamp)

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(3% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200…1999 Ω 1 Ω ±5% m.v.
2000…9999 Ω 1 Ω ±8% m.v.

• voltage on open terminals: selectable 25 V AC or 50 V AC,
• measurement current: under short circuit >20 mA,
• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz (for networks 60 Hz)
Measurement of resistance of auxiliary electrodes RH i RS

Range Resolution Accuracy
0…999 Ω 1 Ω ±(5% m.v.+ 8 digits)
1,00k…9,99 kΩ 0,01 kΩ
10,0k…19,9 kΩ 0,1 kΩ

 

Measurement of multiple earthing resistance with using double clamps

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(10% m.v. + 8 digits)
20,0…99,9 Ω 0,1 Ω ±(20% m.v. + 3 digits)

• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz
(for networks 60 Hz)

Measurement of ground resistivity 
Measurement method: Wenner, ρ=2πLRE

Range Resolution Accuracy
0,00…9,99 Ωm 0,01 Ωm depending on measurement
accuracy RE with 4p method,
but not less than ±1 digit
10,0…99,9 Ωm 0,1 Ωm
100…999 Ωm 1 Ωm
1,00…9,99 kΩm 0,01 kΩm
10,0…99,9 kΩm 0,1 kΩm
100…999 kΩm 1 kΩm

L – distance between probes: 1…50 m.. or 1…150 ft

Electric security:

  • type of insulation: double, according to EN 61010-1 i IEC 61557,
  • measurement category: CAT III 300V wg EN 61010-1,
  • protection class acc. to EN 60529: IP65,

Rated operational conditions:

  • operation temperature: -10…+55°C,
  • storage temperature: -20…+80°C,
  • humidity: 20…90%,

Other technical data:

  • LCD display: segment, backlit,
  • dimensions: 200x150x74 mm.

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MRU-30 Earth Resistance and Resistivity Meter”

There are no reviews yet.

  • UT387A Wall Scanner

    0 out of 5
    (0)
    SKU: n/a
  • SVC 5000VA

    0 out of 5
    (0)

    Input=120V 270
    Output=220
    Under and Over Volt Protection
    Surge Protection
    Over Load and Heat Protection
    Copper Wind with LCD Display

    SKU: n/a
  • UT714 Multifunction Temperature Process Calibrator

    0 out of 5
    (0)

    Features of UT714 Multifunction Temperature Process Calibrator

    Certifications: CE, UKCA

    ● Step/ramp functions

    ● Source and measure accuracy up to 0.02%
    ● Rechargeable battery
    ● Contrast adjustment
    ● Auto power off (Time adjustable)
    ● Stores and recalls setups
    ● USB communication
    SKU: n/a
  • ET 8133 DMM

    0 out of 5
    (0)

    Product description

    3 times/second
    Diode: YES
    Capacitance: YES
    True RMS: YES
    Data hold: YES
    Backlight: YES
    Flashlight: YES
    Auto power off: YES (no measurement operation within 15 minutes)
    Low battery indication: YES
    Environment temperature: 0~40℃, humidity <75%
    Storage environment: -20~60℃, humidity <80%
    DC voltage:
    Range: 200mV/2.000V/20.00V/200.0V/600V
    Resolution: 0.0001V/0.001V/0.01V/0.1V/1V
    Accuracy: ±(0.5%+3)
    Max.: 600V
    AC voltage:
    Range: 2.000V/20.00V/200.0V/600V
    Resolution: 0.001V/0.01V/0.1V/1V
    Accuracy: ±(1.0%+3)
    Max.: 600V
    Capacitance:
    Range: 20.00nF/200.0nF/2.000F/200.0F
    Resolution: 0.01nF/0.1nF/10nF/100nF
    Accuracy: ±5%+3
    Max.: 200μF
    AC current:
    Range: 20mA/200mA, 2A, 10A
    Resolution: 0.1mA/0.001A/0.01A
    Accuracy:
    20mA/200mA/2A: ±(1.0%+3)
    10A: ±(1.5%+3)
    Max.:
    20mA/200mA: 200mA
    2A/10A: 10A
    DC current:
    Range: 20mA/200mA, 2A, 10A
    Resolution: 0.1mA/0.001A/0.01A
    Accuracy:
    20mA/200mA: ±(2.0%+4)
    2A: ±(1.0%+5)
    10A: ±(2.0%+3)
    Max.:
    20mA/200mA: 200mA
    2A/10A: 10A
    Resistance:
    Range: 2.000KΩ/20.00KΩ/200.0KΩ/2.000MΩ/20.00MΩ
    Resolution: 0.001KΩ/0.01KΩ/0.1KΩ/0.001MΩ/0.01MΩ
    Accuracy:
    2.000KΩ: ±(1.5%+3)
    20.00KΩ: ±(0.5%+3)
    200.0KΩ: ±(0.5%+3)
    2.000MΩ: ±(1.0%+3)
    20.00MΩ: ±(1.5%+3)
    Max.: 20MΩ
    Continuity: YES
    NCV: YES
    Frequency response in AC mode: 40Hz~1KHz
    LCD size: 45 * 25mm / 1.8 * 1.0in
    Item size: 124 * 65 * 26mm / 4.9 * 2.6 * 1.0in
    Item weight: 210g / 7.4ounce
    Package size: 140 * 100 * 40mm / 5.5 * 3.9 * 1.6in
    Package weight: 220g / 7.8ounce

    SKU: n/a
  • LM 50A Laser Distance Meters

    0 out of 5
    (0)

    Features of LM A Series Laser Distance Meters

    Certificates: CE, UKCA

    ● Ergonomic exterior, comfortable handling
    ● Millimeter accuracy
    ● 99 groups data storage
    ● Quick, self calculation with real-time readout
    ● Physical leveler(Horizontal and vertical)
    ● Multiple functions: Max/Min/continuous measurement, data storage, etc