MRU-30 Earth Resistance and Resistivity Meter

Availability:

3 in stock


 

  • It allows to take the measurements of:

    • earthing resistance using auxiliary electrodes,
    • earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
    • earthing resistance using double clamps for measuring multiple earthing without underground connections.
    • ground resistivity (Wenner method),
    • continuity of equipotential bondings and protective
    • conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.

    Additionally:

    • measurement of resistance of auxiliary electrodes RS and RH,
    • measurement of interference voltage,
    • measurement in the presence of interference voltage in the power network
    • with frequency 50Hz, 60Hz,
    • selection of maximum measuring voltage (25V and 50V),
    • introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
    • memory of 990 measurements (10 banks of 99 cells each),
    • calibration of clamp used,
    • data transmission to the computer (USB),
    • indication of battery state.

0

3 in stock

Compare

The Sonel MRU-30 uses most known methods of earth resistance measurements. Tests can be performed using the 3-pole, 4-pole, 3-pole with auxiliary clamp and also, additionally, the MRU-30 employs the two clamp method of measurement, without the use of auxiliary test rods which can’t be used in some situations. Complementary features of the MRU-30 are measurements of soil resistivity, continuity measurement of protective and equipotential conductors and, using clamps, leakage currents and interference voltages.

  • Robust and weatherproof (IP65) – no ingress of dust, water protected by a nozzle against enclosure from any direction.
  • Ergonomic casing – small and handy casing to make the measurements more convenient than before.
  • Built-in rechargeable battery – saving time to replace flat batteries; can be recharged from Power Bank and Cigarette Lighter Socket!
  • Clear on-screen notes – displayed on screen before and after the measurement to alert user of possible dangers and irregularities.
  • Many measurement methods available in a small, portable casing
Weight 5 kg
Dimensions 20 × 15 × 7 cm

Measurement of interference voltage UN (RMS)

Range Resolution Accuracy
0…100 V 1 V ±(10% m.v. + 1 digit)

Measurement of continuity of equipotential bondings and protective conductors (Rcont)
measurement range to IEC 61557-4:2007: 0,13 Ω…1999 Ω

Range Resolution Accuracy
0,00…9,99 Ω 0,01 Ω ±(2% m.v. + 3 digits)
10,0…99,9 Ω 0,1 Ω
100…1999 Ω 1 Ω

• measurement current: under short circuit >200mA
• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz (for networks 60 Hz)

Measurement of earthing resistance (method 3- and 4-pole)
measurement range to IEC 61557-5:2007: 0,53 Ω…9999 Ω (dla 50 V)

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(3% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200,0…1999 Ω 1 Ω ±5% m.v.
2000…9999 Ω 1 Ω ±8% m.v.

• measurement current: under short circuit >20 mA,
• voltage on open terminals: selectable 25 V AC or 50 V AC,
• frequency of measurement current: 125 Hz (for networks 50 Hz) or 150 Hz (for 60 Hz).

Measurement of multiple earthing esistance with using the clamp and auxiliary electrodes (3p + clamp)

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(3% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200…1999 Ω 1 Ω ±5% m.v.
2000…9999 Ω 1 Ω ±8% m.v.

• voltage on open terminals: selectable 25 V AC or 50 V AC,
• measurement current: under short circuit >20 mA,
• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz (for networks 60 Hz)
Measurement of resistance of auxiliary electrodes RH i RS

Range Resolution Accuracy
0…999 Ω 1 Ω ±(5% m.v.+ 8 digits)
1,00k…9,99 kΩ 0,01 kΩ
10,0k…19,9 kΩ 0,1 kΩ

 

Measurement of multiple earthing resistance with using double clamps

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(10% m.v. + 8 digits)
20,0…99,9 Ω 0,1 Ω ±(20% m.v. + 3 digits)

• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz
(for networks 60 Hz)

Measurement of ground resistivity 
Measurement method: Wenner, ρ=2πLRE

Range Resolution Accuracy
0,00…9,99 Ωm 0,01 Ωm depending on measurement
accuracy RE with 4p method,
but not less than ±1 digit
10,0…99,9 Ωm 0,1 Ωm
100…999 Ωm 1 Ωm
1,00…9,99 kΩm 0,01 kΩm
10,0…99,9 kΩm 0,1 kΩm
100…999 kΩm 1 kΩm

L – distance between probes: 1…50 m.. or 1…150 ft

Electric security:

  • type of insulation: double, according to EN 61010-1 i IEC 61557,
  • measurement category: CAT III 300V wg EN 61010-1,
  • protection class acc. to EN 60529: IP65,

Rated operational conditions:

  • operation temperature: -10…+55°C,
  • storage temperature: -20…+80°C,
  • humidity: 20…90%,

Other technical data:

  • LCD display: segment, backlit,
  • dimensions: 200x150x74 mm.

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MRU-30 Earth Resistance and Resistivity Meter”

There are no reviews yet.

  • YH 929D V ELECTRIC VACUUM DESOLDERING IRON

    0 out of 5
    (0)

    About this item

    • This 929D-V desoldering iron integrates soldering iron and desoldering pump, you can enjoy the single-handed and continuous desoldering with its short charging handle to rid the hassle of changing grip positions. If you are looking to purchase a desoldering tool that can handle the desoldering jobs of through-hole components and removing excess solder (solder bridges) without jamming up, this is a great choice.
    • This is a plug-n-play desoldering iron. Plug in the power plug, allow the desoldering iron to preheat for approximately 3 minutes, and you are ready to go. YIHUA exclusive heating system combined with a strong desoldering pump ensures you experience uninterrupted desoldering.
    • Different from the traditional use-and-throw desoldering irons, the 929D-V can be used, easily cleaned, and reused. You can lift and pull out the scrap solder storage tube and clean the solder out like a breeze. Meanwhile, we also included 2 different and interchangeable diameters (φ1.0mm & φ1.2mm) desoldering nozzles for different sizes of through-hole components. NOTE: change the nozzle after the desoldering iron has cooled completely.
    • This desoldering iron comes with a heat deflector at the end of the heating element, and this prevents the excess heat from transferring onto the hand when desoldering continuously. You can desolder joints after joints without your hands feeling uncomfortably hot.
    • Choose YIHUA with Confidence – Our US-exclusive 12-month manufacturer warranty will apply to your purchase. Plus, our team is providing professional assistance 24/7 on Amazon. NOTE: This model only works on 110-127V with its USA plug. This product contains electrical insulator protective material (mica), it is normal for the product to emit white fumes for no longer than 20 minutes on first use. This is a normal and intended occurrence for this product, please rest assure for safe usage.
    SKU: n/a
  • CMM-11 Multimeter

    0 out of 5
    (0)
    • manual and automatic range selection
    • HOLD function for holding measured values
    • MAX/MIN” function for displaying extreme values
    • compact housing  – allows to store the device in a pocket
    • increased resistance to falls from heights above 2 m thanks to the elastomer coating
    • built-in Bluetooth module for data transfer to mobile devices
    • built-in flashlight for lighting the measuring places
    • Beeper for sound signal circuit continuity
    • Auto-OFF function for automatic switching off of the unused device
    • display 3¾ digit (count max 4000)
    SKU: n/a
  • LM200C Laser Distance Meters (Discontinued)

    0 out of 5
    (0)

    Features of LM80C/LM120C/LM200C Laser Distance Meters

    ● 2.4-inch color screen

    ● 12 measurement modes
    ● Electronic leveling
    ● 3 selectable measurement references
    ● USB 3.0 supply power
    ● 100 groups of data storage
    ● Rotatable screen
    ● Camera-aided measurement
    ● 2m drop test
    ● IP65 dust and water proof
    SKU: n/a