● Display 6000 counts
● Jaw Opening Ф26mm/1.0″
● Auto Ranging
● Auto Power Off
● Non-Contact Voltage Detector
● Relative Measurement
● Diode Open Volatge 2.7V
● Continuity Buzzer <50±20Ω
● MAX/MIN
● Data Hold
● Display Backlight
● Work Light
● Low Battery Display
Clamp Meters
MS 2109A ACA DCA Digital Clamp Meters
Availability:
10 in stock
● Display 6000 counts
● Jaw Opening Ф26mm/1.0″
● Auto Ranging
● Auto Power Off
● Non-Contact Voltage Detector
● Relative Measurement
● Diode Open Volatge 2.7V
● Continuity Buzzer <50±20Ω
● MAX/MIN
● Data Hold
● Display Backlight
● Work Light
● Low Battery Display
₨10,528 ₨13,162
10 in stock
CompareWeight | 0.3 kg |
---|---|
Dimensions | 22 × 8 × 3 cm |
Specifications | Range | Resolution | Accuracy | |
DC Voltage | 600mV/6V/60V/600V | 0.1mV/0.001V/0.01V/1V | ±(0.7%+2) | |
AC Voltage | 6V/60V | 0.001V/0.01V | ±(0.8%+3) | |
600V | 1V | ±(1.0%+4) | ||
DC Current | 60A/600A | 0.01A/0.1A | ±(3.0%+6) | |
AC Current | 60A/600A | 0.01A/0.1A | ±(2.5%+6) | |
Resistance | 600Ω/6kΩ/60kΩ/600kΩ | 0.1Ω/0.001kΩ/0.01kΩ/0.1kΩ | ±(0.8%+3) | |
6MΩ/60MΩ | 0.001MΩ/0.01MΩ | ±(1.2%+3) | ||
Capacitance | 40nF/400nF/4µF | 0.01nF/0.1nF/0.001µF | ±(4.0%+5) | |
40µF/400µF/4000µF | 0.01µF/0.1µF/1µF | ±(4.0%+5) | ||
Frequency (A) | 100Hz/1kHz | 0.01Hz/0.1Hz | ±(1.5%+5) | |
Frequency (V) | 100Hz/1kHz/10kHz | 0.01Hz/0.1Hz/0.001kHz | ±(1.5%+5) | |
Frequency (Hz/Duty) |
10Hz/100Hz/1kHz/10kHz
|
0.001Hz/0.01Hz/0.1Hz/0.001kHz
|
±(0.5%+3) | |
100kHz/1MHz/10MHz | 0.01kHz/0.1kHz/0.001MHz | ±(0.5%+3) | ||
Duty Cycle | 0.1%~99.9% | 0.1% | ±(3.0%+5) | |
Temperature | -20℃~0℃ | 1℃ | ±(3.0%+4) | |
1℃~400℃ | 1℃ | ±(1.0%+3) | ||
401℃~1000℃ | 1℃ | ±(2.0%) |
Based on 0 reviews
Be the first to review “MS 2109A ACA DCA Digital Clamp Meters”
-
Oscilloscopes
UNI-T MSO3152E 150MHz Mixed Signal 2 Channel Digital Oscilloscope
Analog bandwidth 150MHz 250MHz Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels) Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) Memory depth 70Mpts Waveform capture rate 200,000wfms/s Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display ) Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall] Input impedance (1MΩ±1%) II (20pF±3pF) Input impedance digital (101kΩ±1%) II (9pF±1pF) Vertical scale 1mV/div~20 V/div (1 MΩ) DC gain accuracy <5mV: ±3%, ≥5mV: ±2% Waveform record 100,000 frames Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
CAN, LIN, FlexRayBus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations Auto measurements
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
-Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→AMeasurement display 5 types Measurement statistics Average, Max, Min, standard deviation and number of measurements Frequency counter 6 bits Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA Standard Accessories
USB interface cable UT-D14 Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06 Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05 16CH Logic analyzer probe UT-15M SKU: n/a -
Earth Ground Resistance Testers
MRU-10 Earth Resistance Meter
It allows to:
- measure earthing resistance using auxiliary electrodes,
- measurement of resistance of auxiliary electrodes RS and RH,
- measurement of interference voltage,
- measurement in the presence of interference voltage in the power network with frequency 50 Hz and 60 Hz,
- selection of maximum measuring voltage (25 V and 50 V),
- indication of battery state.