● Display 6000 counts
● Jaw Opening Ф26mm/1.0″
● Auto Ranging
● Auto Power Off
● Non-Contact Voltage Detector
● Relative Measurement
● Diode Open Volatge 2.7V
● Continuity Buzzer <50±20Ω
● MAX/MIN
● Data Hold
● Display Backlight
● Work Light
● Low Battery Display
MS 2109A ACA DCA Digital Clamp Meters
10 in stock
● Display 6000 counts
● Jaw Opening Ф26mm/1.0″
● Auto Ranging
● Auto Power Off
● Non-Contact Voltage Detector
● Relative Measurement
● Diode Open Volatge 2.7V
● Continuity Buzzer <50±20Ω
● MAX/MIN
● Data Hold
● Display Backlight
● Work Light
● Low Battery Display
₨10,528 ₨13,162
10 in stock
CompareWeight | 0.3 kg |
---|---|
Dimensions | 22 × 8 × 3 cm |
Specifications | Range | Resolution | Accuracy | |
DC Voltage | 600mV/6V/60V/600V | 0.1mV/0.001V/0.01V/1V | ±(0.7%+2) | |
AC Voltage | 6V/60V | 0.001V/0.01V | ±(0.8%+3) | |
600V | 1V | ±(1.0%+4) | ||
DC Current | 60A/600A | 0.01A/0.1A | ±(3.0%+6) | |
AC Current | 60A/600A | 0.01A/0.1A | ±(2.5%+6) | |
Resistance | 600Ω/6kΩ/60kΩ/600kΩ | 0.1Ω/0.001kΩ/0.01kΩ/0.1kΩ | ±(0.8%+3) | |
6MΩ/60MΩ | 0.001MΩ/0.01MΩ | ±(1.2%+3) | ||
Capacitance | 40nF/400nF/4µF | 0.01nF/0.1nF/0.001µF | ±(4.0%+5) | |
40µF/400µF/4000µF | 0.01µF/0.1µF/1µF | ±(4.0%+5) | ||
Frequency (A) | 100Hz/1kHz | 0.01Hz/0.1Hz | ±(1.5%+5) | |
Frequency (V) | 100Hz/1kHz/10kHz | 0.01Hz/0.1Hz/0.001kHz | ±(1.5%+5) | |
Frequency (Hz/Duty) |
10Hz/100Hz/1kHz/10kHz
|
0.001Hz/0.01Hz/0.1Hz/0.001kHz
|
±(0.5%+3) | |
100kHz/1MHz/10MHz | 0.01kHz/0.1kHz/0.001MHz | ±(0.5%+3) | ||
Duty Cycle | 0.1%~99.9% | 0.1% | ±(3.0%+5) | |
Temperature | -20℃~0℃ | 1℃ | ±(3.0%+4) | |
1℃~400℃ | 1℃ | ±(1.0%+3) | ||
401℃~1000℃ | 1℃ | ±(2.0%) |
Based on 0 reviews
Be the first to review “MS 2109A ACA DCA Digital Clamp Meters”
-
Watt Meter
UT71E Intelligent Digital Multimeters
1. 40,000 counts, and basic DCV accuracy of 0.025%
2. Can set the interval for auto data recording
3. MAX/MIN/REL measurement mode
4. Peak hold
5. Analogue bar graph
6. Measure AC and DC in the same stall (AC+DC)
7. 4-20mA loop test
8. 45Hz~100kHz frequency response measurement
9. Double backlight
10. Misplug alarm
11. Auto and manual ranges selectable
12. USB interface available
13. Bluetooth connection with a cellphone for data monitoring
14.Power measurement mode
15. Temperature measurement mode, equipped with K-type point contact temperature probe
16. Complies with CE (European Union) and UL (United States) directives
SKU: n/a -
Wire & Cable Testers
TDR-420 Time Domain Reflectometer/ Cable Fault Locator
Product features
- Possibility damage-free location of impedance changes of tested cables and wires such as:
- shorted conductor,
- open conductor / end of cable – useful during the inventory of warehouses and stores,
- splice,
- splitter,
- water ingress,
- wet splice,
- bridge tap
- or other changes.
- Single measurement mode ONCE,
- Continuously measurement mode CONT,
- Tone signal generator TONE,
- Two cursors to mark two places of damage along with an indication of the distance between them,
- Built-in HELP function for easier interpretation of the reflectogram,
- 11 available measuring ranges from 7 m to 6000 m,
- „dead zone” limited to 0.6 m,
- Color 3,5” LCD TFT display with resolution 320 x 240 pixels,
- manually set of sensitivity in 8 steps GAIN,
- output impedance regulation up to 200 Ω (possibility of measuring pre-insulated pipes),
- Velocity of Propagation set in range from 10% to 99%,
- tight and durable housing with IP67 ingress protection degree.
- Small size and weight.
SKU: n/a - Possibility damage-free location of impedance changes of tested cables and wires such as:
-
Insulation Tester
MIC-5001, 5000V Insulation Tester
Insulation resistance measurement in a compact, light-weight, low-cost design.
- Measurement to 5 TΩ
- Measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps
- Continuous indication of insulation resistance or leakage current
- Automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement
- Audio beeps every five seconds to alert user test is proceeding, and to get time characteristics
- Measured test times of T1, T2 and T3 for measuring Absorption Coefficient, Dielectric Absorption Ratio DAR. and Polarization Index PI
- Continuous display of test voltage during the measurement
- Protection against measuring live objects
- Two and three-lead measurement method
- Ramp Test Insulation resistance measurement
- Measurement of breakdown voltage with increments up to 1 kV / s
- Measurement of alternating and direct voltages from 0 V to 750 V
- 990 cells of memory (11880 records) to record results
- Data transfer to PC via USB cable
- Built-in rechargeable battery pack
- Meets the requirements of the EN 61557 standard
- Charge from optional car lighter (12 V) socket accessory