● Display 6000 counts
● Jaw Opening Ф26mm/1.0″
● Auto Ranging
● Auto Power Off
● Non-Contact Voltage Detector
● Relative Measurement
● Diode Open Volatge  2.7V
● Continuity Buzzer  <50±20Ω
● MAX/MIN
● Data Hold
● Display Backlight
● Work Light
● Low Battery Display

10,528 13,162

10 in stock

Compare

● Display 6000 counts
● Jaw Opening Ф26mm/1.0″
● Auto Ranging
● Auto Power Off
● Non-Contact Voltage Detector
● Relative Measurement
● Diode Open Volatge  2.7V
● Continuity Buzzer  <50±20Ω
● MAX/MIN
● Data Hold
● Display Backlight
● Work Light
● Low Battery Display

Category:
Weight 0.3 kg
Dimensions 22 × 8 × 3 cm
Specifications Range Resolution Accuracy
DC Voltage 600mV/6V/60V/600V 0.1mV/0.001V/0.01V/1V ±(0.7%+2)
AC Voltage 6V/60V 0.001V/0.01V ±(0.8%+3)
600V 1V ±(1.0%+4)
DC Current 60A/600A 0.01A/0.1A ±(3.0%+6)
AC Current 60A/600A 0.01A/0.1A ±(2.5%+6)
Resistance 600Ω/6kΩ/60kΩ/600kΩ 0.1Ω/0.001kΩ/0.01kΩ/0.1kΩ ±(0.8%+3)
6MΩ/60MΩ 0.001MΩ/0.01MΩ ±(1.2%+3)
Capacitance 40nF/400nF/4µF 0.01nF/0.1nF/0.001µF ±(4.0%+5)
40µF/400µF/4000µF 0.01µF/0.1µF/1µF ±(4.0%+5)
Frequency (A) 100Hz/1kHz 0.01Hz/0.1Hz ±(1.5%+5)
Frequency (V) 100Hz/1kHz/10kHz 0.01Hz/0.1Hz/0.001kHz ±(1.5%+5)
Frequency
(Hz/Duty)
10Hz/100Hz/1kHz/10kHz
0.001Hz/0.01Hz/0.1Hz/0.001kHz
±(0.5%+3)
100kHz/1MHz/10MHz 0.01kHz/0.1kHz/0.001MHz ±(0.5%+3)
Duty Cycle 0.1%~99.9% 0.1% ±(3.0%+5)
Temperature -20℃~0℃ 1℃ ±(3.0%+4)
1℃~400℃ 1℃ ±(1.0%+3)
401℃~1000℃ 1℃ ±(2.0%)

Brand

MASTECH

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MS 2109A ACA DCA Digital Clamp Meters”

There are no reviews yet.

  • MIC-5001, 5000V Insulation Tester

    0 out of 5
    (0)

    Insulation resistance measurement in a compact, light-weight, low-cost design.

    • Measurement to 5 TΩ
    • Measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps
    • Continuous indication of insulation resistance or leakage current
    • Automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement
    • Audio beeps every five seconds to alert user test is proceeding, and to get time characteristics
    • Measured test times of T1, T2 and T3 for measuring Absorption Coefficient, Dielectric Absorption Ratio DAR. and Polarization Index PI
    • Continuous display of test voltage during the measurement
    • Protection against measuring live objects
    • Two and three-lead measurement method
    • Ramp Test Insulation resistance measurement
    • Measurement of breakdown voltage with increments up to 1 kV / s
    • Measurement of alternating and direct voltages from 0 V to 750 V
    • 990 cells of memory (11880 records) to record results
    • Data transfer to PC via USB cable
    • Built-in rechargeable battery pack
    • Meets the requirements of the EN 61557 standard
    • Charge from optional car lighter (12 V) socket accessory
    SKU: n/a
  • LM100 Laser Distance Meter

    0 out of 5
    (0)

    1. Ergonomic exterior, comfortable handling

    2. Millimeter accuracy
    3. Large, multiple angle HD display
    5. Physical and electronics leveler
    6. Multiple functions: Max/Min/continuous measurement, displacement calculation, data storage, and more
    7. Auto power off after 3 minutes without operation
    SKU: n/a
  • UNI-T UTi260E Professional Handheld IR Thermal Camera 256×192 pixels Wide Temperature -20ºC~550ºC with PC,WiFi,App Real Time Display

    0 out of 5
    (0)

    UTi260B

    Motor inspection:
    Using UNI-T thermal imager can detect the imbalance loading, overloading, wiring error and parts malfunction etc. Heat insulation protection is the key action for avoid fire risk, engineer can also use the thermal imager check the protection situation regularly to ensure the safety production.

    PCBA inspection:
    Using UNI-T thermal imager can quickly locate the components where temperature is abnormally higher.

    Electric inspection:
    Using UNI-T thermal imager to check the device temperature can find the problems in time on switcher, contactor, transformer etc, which maybe caused by oxidation, corrosion, poor contact.

    SKU: n/a
  • CMP-1006 Digital Clamp-on multimeter

    0 out of 5
    (0)

     

    Additionally:

    • safe, insulated measuring clamps,
    • autoranging/manual range selection,
    • DATA HOLD function, for holding measured values,
    • backlit LCD,
    • DC ZERO mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored zero value,
    • MAX/MIN function,
    • over range indication,
    • AUTO-OFF function.
    SKU: n/a
  • ,

    Mechanic T12 Pro Intelligent Temperature Control Anti-Static Soldering Station

    0 out of 5
    (0)
      • Intelligent digital display
      • 450°C high temperature
      • Heat up in 4 seconds
      • Regular dormancy
      • Small and portable
      • Safe and convenient
    SKU: n/a