-8%

Fluke 18B+ Digital Multimeter

Availability:

Out of stock


Feature:

-New Function:Frequency Test

-New Desgin: A Large LCD than FLUKE 18B, with a high brightness LCD Back light

-Two Mode LED Test :

-DMM LED Socket Test Mode .

-UUT(PCBA) LED Test Mode(using test lead).

-Light up LED without considering the polarity.

-Voltage,Resistance,Continuity Testing,Capacitance Test.

-Data Hold,Diode Test.

-Frequency and Duty Cycle.

-MAX Input Current 10A.

 

 

30,270 32,905

Out of stock

Compare

FLUKE 18B+ AC/DC Voltage,Current,Capacitance,Ohm Auto/Manual Range Digital multimeter with LED Test

Category:
Weight 1 kg
Dimensions 16 × 8 × 9 cm

Specifications:

 

Feature Range Resolution Accuracy
AC Voltage(40-500Hz) 4.000 V

40.00 V

400.0 V

1000 V

0.001 V

0.01 V

0.1 V

1 V

1.0 % + 3
DC Voltage 4.000 V

40.00 V

400.0 V

1000 V

0.001 V

0.01 V

0.1 V

1 V

0.5 % + 3
AC Voltage(mV) 400.0 mV 0.1 mV 3.0 % + 3
DC Voltage(mV) 400.0 mV 0.1 mV 1.0 % + 10
Diode 2.000 V 0.001 V 10%
Resistance 400.0 Ω

4.000 kΩ

40.00 kΩ

400.0 kΩ

4.000 MΩ

40.00 MΩ

0.1 Ω

0.001 kΩ

0.01 kΩ

0.1 kΩ

0.001 MΩ

0.01 MΩ

0.5 % + 3

0.5 % + 2

0.5 % + 2

0.5 % + 2

0.5 % + 2

1.5% + 3

Capacitance 40.00 nF

400.0 nF

4.000 μF

40.00 μF

400.0 μF

1000 μF

0.01 nF

0.1 nF

0.001 μF

0.01 μF

0.1 μF

1 μF

2 % + 5

2 % + 5

5 % + 5

5 % + 5

5 % + 5

5 % + 5

Frequency 50.00 Hz

500.0 Hz

5.000 kHz

50.00 kHz

100.0 kHz

0.01 Hz

0.1 Hz

0.001 kHz

0.01 kHz

0.1 kHz

0.1 % + 3
Duty Cycle 1 % to 99 % 0.1%
AC Current

uA (40-400Hz)

400.0 μA

4000 μA

0.1 μA
1 μA
1.5 % + 3
AC Current

mA(40-400Hz)

40.00 mA

400.0 mA

0.01 mA

0.1 mA

1.5 % + 3
AC Current

A(40-400Hz)

4.000 A

10.00 A

0.001 A

0.01 A

1.5 % + 3
DC Current (uA) 400.0 μA

4000 μA

0.1 μA

1 μA

1.5 % + 3
DC Current (mA) 40.00 mA

400.0 mA

0.01 mA

0.1 mA

1.5 % + 3
DC Current (A) 4.000 A

10.00 A

0.001 A

0.01 A

1.5 % + 3

 

LED Test and On-off Threshold:

 

Feature Lighting Range measuring range Resolution Accuracy
LED VF Test(LED Test Socket) 1.00-6.00V N/A N/A N/A
LED VF Test(Test Lead) 1.00-6.00V 1.00-6.00V 0.01V 10%
On-off threshold N/A N/A N/A 70Ω

 

Input Parameter:

 

Feature Overload Protect Input Impedance Common Mode Rejection Ratio Conventional mode rejection ratio
AC Voltage 1000V >10MΩ,<100pF DC,Frequency Between 50Hz to 60Hz, >60dB N/A
AC Voltage(mV) 400mV >1MΩ,<100pF Frequency Between 50Hz to 60Hz,>80dB N/A
DC Voltage 1000V >10MΩ,<100pF DC,Frequency Between 50Hz to 60Hz,>100dB Frequency Between 50Hz to 60Hz,>60dB
DC Voltage(mV) 400mV >1MΩ,<100pF Frequency Between 50Hz to 60Hz,>80dB N/A

 

Package Included:

Fluke 18B+*1

Test Lead*1

Manual *1

Battery(Not Included)

Brand

FLUKE

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Fluke 18B+ Digital Multimeter”

There are no reviews yet.

  • MC TIP OT IS

    0 out of 5
    (0)
    SKU: n/a
  • YIHUA 303D DC Power Supply

    0 out of 5
    (0)

    Feature

    303D communication maintenance power supply is a single line output of stabilized high accuracy

    DC stabilized power supply. The output voltage and current can be adjusted continuously within the

     rated range. The load current has MA conversion with two settings: 0-3A and 0-99 mA. Constant

    voltage and constant current (CV/CC), automatic switching of working modes. Double digital display

    shows output voltage and current independently. Several protection functions include current

     limitation, voltage reduction, short circuit protection, over-temperature protection, etc. The design

     is applied to production line of the plant, maintenance, laboratories and is also a necessary device

    for the communication industry.

    SKU: n/a
  • UT622A Digital Inductance LCR Meter

    0 out of 5
    (0)
    Specifications UT622A UT622C UT622E
    Certificates CE, RoHS
    Test frequency 100Hz, 120Hz, 1kHz, 10kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz
    Test signal level  0.1Vrms, 0.3Vrms, 1Vrms
    Output impedance 100Ω
    Measurement parameters Primary: L/C/R/Z
    Secondary: D/Q/θ/ESR
    Primary: L/C/R/Z/DCR  Secondary: D/Q/θ/ESR
    Auto LCR
    Test terminals Three-terminal test jacks, five-terminal test sockets
    Test rate Fast (20 times/s), medium (5 times/s), or slow (2 times/s)
    DCR test rate Fast (20 times/s), medium (5 times/s), or slow (2 times/s)
    Ranging mode Auto/hold
    Tolerance range 1%~20%
    Testing circuit mode Series/parallel mode
    Clearing correction Open/short circuit
    Fuse of test ports 0.1A/250V
    Communication interface Mini-USB
    LED alarm for tolerance
    (pass: green; fail: red)
    Display range
    Maximum reading 99999
    Minimum resolution 0.0001
    Maximum accuracy 0.001
    L 0.00μH~99.999H
    C 0.00pF~99.999mF
    Z/R 0.0000Ω~9.9999MΩ
    ESR 0.0000Ω~999.99Ω
    D 0.0000~9.9999
    Q 0.0000~99999
    θ -179.9°~179.9°
    DCR 0.01mΩ–20.000MΩ
    Temperature coefficient 0.1× (specified accuracy) /°C (0°C~18°C or 28°C~40°C)
    General Characteristics
    Power 3.7V 1800mAh lithium polymer battery; Input: 220V (1±10%), 50Hz (1±5%); Mini-USB output: 5V, 1A
    Display 2.8′ TFT LCD 320X240
    Product net weight 420g
    Product size 93mm x 192mm x 44mm
    Standard accessories Short circuit board (UTR-001), USB cable, 5V 1A power adapter, Four-terminal Kelvin testleads (UTR-L100k-H) (UT622C/E), Alligator clip test leads with rubber plugs (UTR-002)(UT622A), English manual
    SKU: n/a
  • CMP-2000 Digital clamp-on multimeter

    0 out of 5
    (0)

    It provides:

    • AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
    • Measurement of INRUSH current in start-up phase of electrical device.
    • AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
    • Resistance measurement and continuity test:
      – continuity test with acoustic signalling (beeper) for resistance below 30 Ω.
    • Capacitance measurement.
    • Temperature measurement (Fahrenheit or Celsius).
    • Frequency measurement.
    • Duty cycle measurement.
    • Diode test.
    SKU: n/a