FLUKE 18B+ AC/DC Voltage,Current,Capacitance,Ohm Auto/Manual Range Digital multimeter with LED Test
Fluke 18B+ Digital Multimeter
Out of stock
Feature:
-New Function:Frequency Test
-New Desgin: A Large LCD than FLUKE 18B, with a high brightness LCD Back light
-Two Mode LED Test :
-DMM LED Socket Test Mode .
-UUT(PCBA) LED Test Mode(using test lead).
-Light up LED without considering the polarity.
-Voltage,Resistance,Continuity Testing,Capacitance Test.
-Data Hold,Diode Test.
-Frequency and Duty Cycle.
-MAX Input Current 10A.
₨30,270 ₨32,905
Out of stock
CompareWeight | 1 kg |
---|---|
Dimensions | 16 × 8 × 9 cm |
Specifications:
Feature | Range | Resolution | Accuracy |
AC Voltage(40-500Hz) | 4.000 V
40.00 V 400.0 V 1000 V |
0.001 V
0.01 V 0.1 V 1 V |
1.0 % + 3 |
DC Voltage | 4.000 V
40.00 V 400.0 V 1000 V |
0.001 V
0.01 V 0.1 V 1 V |
0.5 % + 3 |
AC Voltage(mV) | 400.0 mV | 0.1 mV | 3.0 % + 3 |
DC Voltage(mV) | 400.0 mV | 0.1 mV | 1.0 % + 10 |
Diode | 2.000 V | 0.001 V | 10% |
Resistance | 400.0 Ω
4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω
0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5 % + 3
0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 |
Capacitance | 40.00 nF
400.0 nF 4.000 μF 40.00 μF 400.0 μF 1000 μF |
0.01 nF
0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2 % + 5
2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
Frequency | 50.00 Hz
500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz
0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
0.1 % + 3 |
Duty Cycle | 1 % to 99 % | 0.1% | |
AC Current
uA (40-400Hz) |
400.0 μA
4000 μA |
0.1 μA 1 μA |
1.5 % + 3 |
AC Current
mA(40-400Hz) |
40.00 mA
400.0 mA |
0.01 mA
0.1 mA |
1.5 % + 3 |
AC Current
A(40-400Hz) |
4.000 A
10.00 A |
0.001 A
0.01 A |
1.5 % + 3 |
DC Current (uA) | 400.0 μA
4000 μA |
0.1 μA
1 μA |
1.5 % + 3 |
DC Current (mA) | 40.00 mA
400.0 mA |
0.01 mA
0.1 mA |
1.5 % + 3 |
DC Current (A) | 4.000 A
10.00 A |
0.001 A
0.01 A |
1.5 % + 3 |
LED Test and On-off Threshold:
Feature | Lighting Range | measuring range | Resolution | Accuracy |
LED VF Test(LED Test Socket) | 1.00-6.00V | N/A | N/A | N/A |
LED VF Test(Test Lead) | 1.00-6.00V | 1.00-6.00V | 0.01V | 10% |
On-off threshold | N/A | N/A | N/A | 70Ω |
Input Parameter:
Feature | Overload Protect | Input Impedance | Common Mode Rejection Ratio | Conventional mode rejection ratio |
AC Voltage | 1000V | >10MΩ,<100pF | DC,Frequency Between 50Hz to 60Hz, >60dB | N/A |
AC Voltage(mV) | 400mV | >1MΩ,<100pF | Frequency Between 50Hz to 60Hz,>80dB | N/A |
DC Voltage | 1000V | >10MΩ,<100pF | DC,Frequency Between 50Hz to 60Hz,>100dB | Frequency Between 50Hz to 60Hz,>60dB |
DC Voltage(mV) | 400mV | >1MΩ,<100pF | Frequency Between 50Hz to 60Hz,>80dB | N/A |
Package Included:
Fluke 18B+*1
Test Lead*1
Manual *1
Battery(Not Included)
Based on 0 reviews
Be the first to review “Fluke 18B+ Digital Multimeter”
-
DC Power Supplies
YIHUA 303D DC Power Supply
Feature
303D communication maintenance power supply is a single line output of stabilized high accuracy
DC stabilized power supply. The output voltage and current can be adjusted continuously within the
rated range. The load current has MA conversion with two settings: 0-3A and 0-99 mA. Constant
voltage and constant current (CV/CC), automatic switching of working modes. Double digital display
shows output voltage and current independently. Several protection functions include current
limitation, voltage reduction, short circuit protection, over-temperature protection, etc. The design
is applied to production line of the plant, maintenance, laboratories and is also a necessary device
for the communication industry.
SKU: n/a -
LCR Meter
UT622A Digital Inductance LCR Meter
Specifications UT622A UT622C UT622E Certificates CE, RoHS Test frequency 100Hz, 120Hz, 1kHz, 10kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz Test signal level 0.1Vrms, 0.3Vrms, 1Vrms Output impedance 100Ω Measurement parameters Primary: L/C/R/Z
Secondary: D/Q/θ/ESRPrimary: L/C/R/Z/DCR Secondary: D/Q/θ/ESR Auto LCR √ Test terminals Three-terminal test jacks, five-terminal test sockets Test rate Fast (20 times/s), medium (5 times/s), or slow (2 times/s) DCR test rate — — Fast (20 times/s), medium (5 times/s), or slow (2 times/s) Ranging mode Auto/hold Tolerance range 1%~20% Testing circuit mode Series/parallel mode Clearing correction Open/short circuit Fuse of test ports 0.1A/250V Communication interface Mini-USB LED alarm for tolerance
(pass: green; fail: red)√ √ √ Display range Maximum reading 99999 Minimum resolution 0.0001 Maximum accuracy 0.001 L 0.00μH~99.999H C 0.00pF~99.999mF Z/R 0.0000Ω~9.9999MΩ ESR 0.0000Ω~999.99Ω D 0.0000~9.9999 Q 0.0000~99999 θ -179.9°~179.9° DCR — — 0.01mΩ–20.000MΩ Temperature coefficient 0.1× (specified accuracy) /°C (0°C~18°C or 28°C~40°C) General Characteristics Power 3.7V 1800mAh lithium polymer battery; Input: 220V (1±10%), 50Hz (1±5%); Mini-USB output: 5V, 1A Display 2.8′ TFT LCD 320X240 Product net weight 420g Product size 93mm x 192mm x 44mm Standard accessories Short circuit board (UTR-001), USB cable, 5V 1A power adapter, Four-terminal Kelvin testleads (UTR-L100k-H) (UT622C/E), Alligator clip test leads with rubber plugs (UTR-002)(UT622A), English manual SKU: n/a -
Clamp Meters
CMP-2000 Digital clamp-on multimeter
It provides:
- AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
- Measurement of INRUSH current in start-up phase of electrical device.
- AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
- Resistance measurement and continuity test:
– continuity test with acoustic signalling (beeper) for resistance below 30 Ω. - Capacitance measurement.
- Temperature measurement (Fahrenheit or Celsius).
- Frequency measurement.
- Duty cycle measurement.
- Diode test.
SKU: n/a