PQM-707 Power Quality Analyzer


  • Features:

    • 7″ touch screen – intuitive operating
    • CAT IV 600V – high safety
    • all parameters acc. to class S – high accuracy of measurements
    • Li-Ion rechargeable battery – higher mobility
    • removable memory card – recording data with no restrictions

    Possible measurements:

    • Measurements according to EN 50160,
    • Voltage L1, L2, L3, N-PE (five inputs),
      – average, minimum, maximum values, range to 760 V, ability to work with voltage transformers,
    • Current L1, L2, L3, N (four inputs),
      – average, minimum, maximum values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers,
    • Crest factor for voltage and current,
    • Frequency from 40 Hz to 70 Hz ,
    • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
    • Power recording:
      • Budeanu method,
      • IEEE 1459,
    • Active, reactive, apparent energy,
    • Power factor, cosφ, tgφ,
    • Up to 50th harmonics for voltage and current,
    • Total Harmonic Distortion (THD) for voltage and current,
    • Short-term (PST) and long-term (PLT) flicker,
    • Unbalance of voltage and current,
    • Current and voltage events registration including waveforms and RMS graphs half period,
    • Inrush current
    • Calculator of energy tariffs
    • ANALYZER MEASURES AND RECORDS ACCORDING TO THE IEC 61000-4-30 CLASS S STANDARD.

0

Compare

Power Quality Analyzer Sonel PQM-707 is an autonomous meter allowing for versatile measurement, analysis, and registration of energy networks parameters DC and 50/60Hz, including the quality of electric energy in accordance with the European standard EN 50160 and the Regulation of the Minister of Economy on detailed conditions of the  electro-energetic system functioning. All parameters are measured in the S class of the IEC 61000-4-30 STANDARD guaranteeing high accuracy of measurements.
The largest in this class of analyzers 7-inch colour touch screen enables intuitive and ergonomic operation. Thanks to the built-in lithium-ion battery, the analyzer allows for efficient work during the measurement without the necessity of connecting an external AC adapter.

The analyzer is directed to a very wide range of users, with particular reference to the maintenance staff. Due to its mobility and autonomy, any problems occurring in the supply networks can be diagnosed on the spot. High measurement category (CAT IV 600V) makes the analyzer very safe, which provides peace of mind during every day use.
The analyzer can be used in virtually all kinds of networks with rated voltage from 54V to 760V directly, or indirectly via transformers.
Because of that PQM-707 can be used in the field of professional power engineering, maintenance services in industrial plants, as well as among those providing services focused on network analysis.

Accessories:

  • Test leads 2.2 m
  • Mains cable with IEC C7 plug
  • Crocodile clips, black,yellow,red,blue.
  • Power supply adaptor Z7
  • USB Transmission Cable
  • Carrying Case
  • F-3A flexible clamps (Φ=120 mm)
  • AC-16 line Splitter
  • AZ-2 Power Supply Adaptor
  • Cable for Battery
  • Magnetic voltage adapter (set – 4 pcs)

The device is designed to work with networks:

  • with nominal frequency 50/60 Hz,
  • with nominal voltage: 64/110 V; 110/190 V; 115/200 V; 127/220 V; 220/380 V; 230/400 V; 240/415 V; 254/440 V; 290/500 V; 400/690 V.
  • DC network

Supported networks:

  • single-phase,
  • two-phase with common N conductor,
  • three-phase star connection with and without N conductor,
  • three-phase delta.
  • Parameters of analyzer:

    Parametr Parametr Measurement range Max. resolution Accuracy
    Alternating voltage (TRMS) 0,0…760,0 V 0,01 % Unom ±0,5% Unom
    Crest Factor Voltage 1,00…10,00 (≤1.65 for 690 V voltage) 0,01 ±5%
    Crest Factor Current 1,00…10,00 (≤3,6 Inom) 0,01 ± 5%wm
    Alternating current TRMS depending on clamp* 0,01 % Inom ±2% m.v. for m.v. ≥ 10% Inom ±2% Inom for m.v. < 10% Inom(error does not account for clamps error)
    Frequency 40,00…70,00 Hz 0,01 Hz ±0,05 Hz
    Active, reactive, apparent and distortion power depending of configuration (trasformers, clamp) up to for decimal places depending on configuration (transformers, clamps)
    Active, reactive apparent energy depending of configuration (transformers, clamp) up to for decimal places as power error
    cosφ and power factor (PF) 0,00…1,00 0,01 ±0,03
    Tgφ 0,00…10,00 0,01 depends on active and reactive power error
    Harmonics Voltage as for alternating voltage True RMS as for alternating voltage True RMS ±5% m.v. for m.v. ≥ 3% Unom ±0,15% Unom for m.v.. < 3% Unom
    Harmonics Current as for alternating voltage True RMS as for alternating voltage True RMS ±5% m.v. for m.v.. ≥ 10% Inom ±0,5% Inom for m.v. < 10% Inom
    THD Voltage 0.0..100.0% (in regards to the rms value) 0,1% ±5%
    THD Current 0.0..100.0% (in regards to the rms value) 0,1% ±5%
    Flicker severity PST, PLT 0,40…10,00 0,01 ±10%
    Voltage asymmetry Voltage and current 0,0…10,0% 0,1% ±0,15% (absolute error)
    Inrush current depending on clamp* 0,01% Inom ±4% m.v. for m.v. ≥ 10% Inom ±4% Inom for m.v. < 10% Inom(RMS1/2)

    *Clamp F-1A, F-2A, F-3A: 0..3000 A (10000 Ap-p)

    *Clamp C-4A: 0..1000 A (3600 Ap-p)

    *Clamp C-5A: 0..1000 A (3600 Ap-p)

    *Clamp C-6A: 0..10 A (36 Ap-p)

    *Clamp C-7A: 0…100 A (360 Ap-p)

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “PQM-707 Power Quality Analyzer”

There are no reviews yet.

  • UTD2102CEX-II Digital Storage Oscilloscope

    0 out of 5
    (0)

    1. 2 channels

    2. 70MHz/100MHz bandwidth; 1GSa/s real-time sampling rate
    3. Up to 28Mpts memory depth
    4. Calibration signal output: 10Hz, 100Hz, 1kHz (by default),
    10kHz or 100kHz
    5. Max 10Mpts waveform record
    6. 8-inch TFT LCD, WVGA (800X480)
    SKU: n/a
  • YH TIP 902

    0 out of 5
    (0)
    SKU: n/a
  • UT352 Sound Level Meter

    0 out of 5
    (0)

    1. MAX/MIN modes

    2. Auto power off (cancelable)

    3. 63 sets data storage

    4. AC/DC analog signal output

    5. Over/under range indication

    6. Data hold, LCD backlight

    7. Simulated analog bar

    8. A (ear)/C (machine) weighting modes

    9. Manual/auto range selectable

    10. Fast/slow response rate (fast: 125ms, slow: 1s)

    11. Powered by batteries or external power source

    SKU: n/a
  • YIHUA 936 Soldering Station

    0 out of 5
    (0)

    Application Scope


    1. Production lines for electronic products , suitable for desoldering of small solder joints ,components.
      2. Repair industry for moblie phone.
      3. SMD components requiring the highest precision
    SKU: n/a
  • UNI-T UT622E Handheld LCR Meter

    0 out of 5
    (0)

    Features of UNI-T UT622E Handheld LCR Meter:

    • Up to 0.1% measurement accuracy
    • High-brightness white backlight
    • Ultra-low power consumption and long battery life (8 hours)
    • Maximum test speed: 20 times/s
    • Constant 100Q output impedance
    • Data hold and recording mode
    • Standard Mini-USB interface, SCPI command set
    SKU: n/a
  • UNI-T MSO3152E 150MHz Mixed Signal 2 Channel Digital Oscilloscope

    0 out of 5
    (0)
    Analog bandwidth 150MHz 250MHz
    Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital
    Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels)
    Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels)
    Memory depth 70Mpts
    Waveform capture rate 200,000wfms/s
    Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display )
    Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall]
    Input impedance (1MΩ±1%) II (20pF±3pF)
    Input impedance digital (101kΩ±1%) II (9pF±1pF)
    Vertical scale 1mV/div~20 V/div (1 MΩ)
    DC gain accuracy <5mV: ±3%, ≥5mV: ±2%
    Waveform record 100,000 frames
    Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
    CAN, LIN, FlexRay
    Bus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay
    Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations
     

     

    Auto measurements

    Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
    -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
    channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A
    Measurement display 5 types
    Measurement statistics Average, Max, Min, standard deviation and number of measurements
    Frequency counter 6 bits
    Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA
     

     

    Standard Accessories

    USB interface cable UT-D14
    Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06
    Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05
    16CH Logic analyzer probe UT-15M

     

    SKU: n/a