TDR-410 Cable Fault Locator

Availability:

Out of stock


  • Features:

    • automatic or manual mode:
      • the automatic fault location (AFL),
      • mode with manual range selection and sensitivity,
      • single measurement triggered manually or scanning continuous,
    • 11 available ranges from 7 m to 4000 m selected in manual mode or matched automatically,
    • maximum length of cable up to 4000 m one end of the cable,
    • “Dead zone” measure limited to 0.5 m,
    • 2.5 “LCD screen with backlight,
    • scan automatically or manually trigger,
    • sensitivity set manually or automatically adjusted,
    • adjustable impedance matching,
    • propagation coefficient adjustment 1% to 99%,
    • waterproof and resistant to mechanical housing.
    • small size and weight.
    • economical power system – 30 hours of continuously scan on one battery set..

    Accessories:

    • 0,6 m double-wire lead: WAPRZ0X6DZBB
    • red crocodile clip: WAKRORE20K02
    • Krokodylek czarny: WAKROBL20K01
    • cover M-2: WAFUTM2

0

Out of stock

Compare
  • Location damaged power cables.
  • Fault location copper telecom cables.
  • Coaxial cable fault location.
  • Fault location wiring infrastructure.
  • Detection of breaks, short circuits, damage caused by dampness and other changes in impedance of the cable.
  • Graphic depiction of damage the cable with automatic indication the distance to fault on the screen.

Dechnical data:

  • Ranges Meters: 7, 15, 30, 60, 120, 250, 500, 1km, 2km, 3km, 4km
  • Ranges Feet: 20, 45, 90, 180, 360, 750, 1500, 3000, 6000, 10000, 14000.
  • Range Selection: Manual range control / Auto range.
  • Accuracy: 1% of selected range*.
  • Resolution: Approx 1% of range.
  • Minimum cable lenght: 4m (14ft).
  • Sensitivity: Min 3 pixel return at 4km on 0.6mm Ø, PE, TP.
  • Velocity Factor: Adjustable from 1% to 99%.
  • Output Pulse: 5 volts peak to peak into open circuit.
  • Output Impedance: Selectable 25, 50, 75 & 100 Ω.
  • Output Pulse: Width 3 ns to 3 µs, Automatic with range.
  • Scan Rate: 2 scans/second or scan held, pre set for each range scale.
  • Tone Generator: 810 – 1100Hz.
  • Battery Life: 30 hours continuous scanning.
  • Power Supply: 6 volts 4 x 1.5 AA Alkaline cells, on-screen low voltage indicator.
  • Power Down Selectable: 1, 2, 3, 5 minutes or disabled.
  • Back Lit Display: 128 x 64 pixel.
  • Voltage Protection: 250 volts AC.
  • Operating Temp: -10º / 50ºC.
  • Storage Temp: -20º +70° C.
  • Dimensions: 165 x 90 x 37 mm (6.5 x 3.5 x 1.5 ins).
  • Weight: 350 g (12oz).
  • Safety: IEC 61010-1, EN 60950.
  • EMC: BS/EN 61326-1.
  • Water/Dust Proof: IP54

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “TDR-410 Cable Fault Locator”

There are no reviews yet.

  • UTP3305TFL-II

    0 out of 5
    (0)
    SKU: n/a
  • UT275 Clamp Earth Ground Testers

    0 out of 5
    (0)

    UT270 series can measure the grounding system of a circuit without disconnecting the ground wires and auxiliary electrode. It clamps the grounding circuit and measures the grounding resistance fast and safely. It can measure resistance as low as 0.01Ω and has a high resolution of 0.001Ω. It has overload alarm function, which can help to setup the alarm value within the ranges. The clamp has double insulation, which strengthens the anti-interference.

    SKU: 90000
  • LKZ-1000 Wires and pipe locator

    0 out of 5
    (0)
    • Passive or active modes of tracing.
    • Detection of underground live wires.
    • Detection of underground wires with no voltage (radio mode).
    • Detection of underground wires with no voltage using a transmitter (galvanised, inductive or clamp-based connection).
    • Tracing metallic or non-conductive pipes using an additional probe.
    • Tracing non-conductive pipelines using a “floating” probe.
    • Tracing a determined cable.
    • Determining the depth of a cable.
    SKU: n/a
  • MIC-15k1 ,15kV Insulation Quality Analyzer

    0 out of 5
    (0)

     

    Features:

    • Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD, widened with thepartial discharge (PD) indicator for every each of these measurements.
    • It allows testing the electrical durability of the tested object – breakdown voltage indication.
    • High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and close to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
    • The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility and to carry out a partial location of their occurrence.
    • Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
      • visual method (if power cables are visible along the entire length),
      • reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault (the conductor must be buried in the ground with earth direct contact).
    • Compatible with external software.
    SKU: n/a