  • Features:

    • automatic or manual mode:
      • the automatic fault location (AFL),
      • mode with manual range selection and sensitivity,
      • single measurement triggered manually or scanning continuous,
    • 11 available ranges from 7 m to 4000 m selected in manual mode or matched automatically,
    • maximum length of cable up to 4000 m one end of the cable,
    • “Dead zone” measure limited to 0.5 m,
    • 2.5 “LCD screen with backlight,
    • scan automatically or manually trigger,
    • sensitivity set manually or automatically adjusted,
    • adjustable impedance matching,
    • propagation coefficient adjustment 1% to 99%,
    • waterproof and resistant to mechanical housing.
    • small size and weight.
    • economical power system – 30 hours of continuously scan on one battery set..

    Accessories:

    • 0,6 m double-wire lead: WAPRZ0X6DZBB
    • red crocodile clip: WAKRORE20K02
    • Krokodylek czarny: WAKROBL20K01
    • cover M-2: WAFUTM2

0

Out of stock

Compare
  • Location damaged power cables.
  • Fault location copper telecom cables.
  • Coaxial cable fault location.
  • Fault location wiring infrastructure.
  • Detection of breaks, short circuits, damage caused by dampness and other changes in impedance of the cable.
  • Graphic depiction of damage the cable with automatic indication the distance to fault on the screen.

Dechnical data:

  • Ranges Meters: 7, 15, 30, 60, 120, 250, 500, 1km, 2km, 3km, 4km
  • Ranges Feet: 20, 45, 90, 180, 360, 750, 1500, 3000, 6000, 10000, 14000.
  • Range Selection: Manual range control / Auto range.
  • Accuracy: 1% of selected range*.
  • Resolution: Approx 1% of range.
  • Minimum cable lenght: 4m (14ft).
  • Sensitivity: Min 3 pixel return at 4km on 0.6mm Ø, PE, TP.
  • Velocity Factor: Adjustable from 1% to 99%.
  • Output Pulse: 5 volts peak to peak into open circuit.
  • Output Impedance: Selectable 25, 50, 75 & 100 Ω.
  • Output Pulse: Width 3 ns to 3 µs, Automatic with range.
  • Scan Rate: 2 scans/second or scan held, pre set for each range scale.
  • Tone Generator: 810 – 1100Hz.
  • Battery Life: 30 hours continuous scanning.
  • Power Supply: 6 volts 4 x 1.5 AA Alkaline cells, on-screen low voltage indicator.
  • Power Down Selectable: 1, 2, 3, 5 minutes or disabled.
  • Back Lit Display: 128 x 64 pixel.
  • Voltage Protection: 250 volts AC.
  • Operating Temp: -10º / 50ºC.
  • Storage Temp: -20º +70° C.
  • Dimensions: 165 x 90 x 37 mm (6.5 x 3.5 x 1.5 ins).
  • Weight: 350 g (12oz).
  • Safety: IEC 61010-1, EN 60950.
  • EMC: BS/EN 61326-1.
  • Water/Dust Proof: IP54

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “TDR-410 Cable Fault Locator”

There are no reviews yet.

  • UT61E Modern Digital Multimeters

    0 out of 5
    (0)

    Product Features

    1. 22,000 display count, can measure weak signals

    2. Analogue bar graph

    3. True RMS measurement

    4. 220mF capacitance measurement

    5. Peak hold: auto hold the max/min value of pulse signals

    6. Diode test and buzzer continuity

    7. Auto range

    8. MAX/MIN/REL measurement mode

    9. Overload protection for all ranges

    10. Data hold

    11. Complies with CE (European Union) directives

    SKU: n/a
  • PHASE INDICATOR KEW 8031

    0 out of 5
    (0)

    ・Two Functions in One Unit
    Presence of open phase can be checked by the lamps, and the phase
    sequence can be indicated by the rotating disk.

    ・ High Reliability
    measuring range for 3-phase installations from 110V to 600V.
    Sealed against dust ensures the trouble-free performance.

    ・ Battery-free tester

    SKU: n/a
  • Uni-T UT337 Carbon Monoxide Meter

    0 out of 5
    (0)

    Suitable for use everywhere from in the house to restaurants, offices and industrial areas, the UT337A measures the exact value of carbon monoxide (CO) present in the air. Featuring a built-in sensor integrated into the top of the unit, the UT337A measures CO content from 0-1000ppm with accuracy of ±5% (5ppm) and resolution of 1ppm. The sensor is also designed to adjust rapidly to changes, ensuring you always get a stable, accurate reading. When CO levels exceed a certain threshold, the UT337A will alert the user by using a combination of audible and LED light indicators. The alarm is configurable to the user’s specification and it is also possible to use this meter to calculate temperature values.

    SKU: n/a
  • MECHANIC halogenfree flux paste UV80 [60G]

    0 out of 5
    (0)

    Containing high quality rosin, the use of acid – free flux refined,

    semi – solid is not easy to dump

    Non – corrosive, easy to weld, quick cleaning and good insulation, no acid

    SKU: n/a
  • UT18B Voltage And Continuity Testers

    0 out of 5
    (0)

    UT18 series of test pen with measuring AC and DC voltage (including the three-phase alternating current) measurement, phase of three-phase AC power indicator, on-off test, RCD test, single pen measurement (can determine the zero line or wire), self checking, no battery detection and other functions.
    Suitable for: smelting, electronics, manufacturing, defense, electric power, petroleum, chemical industry. Also used to solve complex problems of electronic, factory automation, power distribution and electrical equipment in.