- Location damaged power cables.
- Fault location copper telecom cables.
- Coaxial cable fault location.
- Fault location wiring infrastructure.
- Detection of breaks, short circuits, damage caused by dampness and other changes in impedance of the cable.
- Graphic depiction of damage the cable with automatic indication the distance to fault on the screen.
Wire & Cable Testers
TDR-410 Cable Fault Locator
Availability:
Out of stock
-
Features:
- automatic or manual mode:
- the automatic fault location (AFL),
- mode with manual range selection and sensitivity,
- single measurement triggered manually or scanning continuous,
- 11 available ranges from 7 m to 4000 m selected in manual mode or matched automatically,
- maximum length of cable up to 4000 m one end of the cable,
- “Dead zone” measure limited to 0.5 m,
- 2.5 “LCD screen with backlight,
- scan automatically or manually trigger,
- sensitivity set manually or automatically adjusted,
- adjustable impedance matching,
- propagation coefficient adjustment 1% to 99%,
- waterproof and resistant to mechanical housing.
- small size and weight.
- economical power system – 30 hours of continuously scan on one battery set..
Accessories:
- 0,6 m double-wire lead: WAPRZ0X6DZBB
- red crocodile clip: WAKRORE20K02
- Krokodylek czarny: WAKROBL20K01
- cover M-2: WAFUTM2
- automatic or manual mode:
₨0
Out of stock
CompareDechnical data:
- Ranges Meters: 7, 15, 30, 60, 120, 250, 500, 1km, 2km, 3km, 4km
- Ranges Feet: 20, 45, 90, 180, 360, 750, 1500, 3000, 6000, 10000, 14000.
- Range Selection: Manual range control / Auto range.
- Accuracy: 1% of selected range*.
- Resolution: Approx 1% of range.
- Minimum cable lenght: 4m (14ft).
- Sensitivity: Min 3 pixel return at 4km on 0.6mm Ø, PE, TP.
- Velocity Factor: Adjustable from 1% to 99%.
- Output Pulse: 5 volts peak to peak into open circuit.
- Output Impedance: Selectable 25, 50, 75 & 100 Ω.
- Output Pulse: Width 3 ns to 3 µs, Automatic with range.
- Scan Rate: 2 scans/second or scan held, pre set for each range scale.
- Tone Generator: 810 – 1100Hz.
- Battery Life: 30 hours continuous scanning.
- Power Supply: 6 volts 4 x 1.5 AA Alkaline cells, on-screen low voltage indicator.
- Power Down Selectable: 1, 2, 3, 5 minutes or disabled.
- Back Lit Display: 128 x 64 pixel.
- Voltage Protection: 250 volts AC.
- Operating Temp: -10º / 50ºC.
- Storage Temp: -20º +70° C.
- Dimensions: 165 x 90 x 37 mm (6.5 x 3.5 x 1.5 ins).
- Weight: 350 g (12oz).
- Safety: IEC 61010-1, EN 60950.
- EMC: BS/EN 61326-1.
- Water/Dust Proof: IP54
Based on 0 reviews
Be the first to review “TDR-410 Cable Fault Locator”
-
-
-
Oscilloscopes
UNI-T MSO3254E 250MHz Mixed Signal 4 Channel Digital Oscilloscope
Analog bandwidth 150MHz 250MHz Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels) Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) Memory depth 70Mpts Waveform capture rate 200,000wfms/s Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display ) Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall] Input impedance (1MΩ±1%) II (20pF±3pF) Input impedance digital (101kΩ±1%) II (9pF±1pF) Vertical scale 1mV/div~20 V/div (1 MΩ) DC gain accuracy <5mV: ±3%, ≥5mV: ±2% Waveform record 100,000 frames Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
CAN, LIN, FlexRayBus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations Auto measurements
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
-Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→AMeasurement display 5 types Measurement statistics Average, Max, Min, standard deviation and number of measurements Frequency counter 6 bits Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA Standard Accessories
USB interface cable UT-D14 Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06 Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05 16CH Logic analyzer probe UT-15M SKU: n/a -
Clamp Meters
UT222 2500A ACA DCA Digital Clamp Meters
UT222 are stable and safe 3 5/6 digit AC&DC digital clamp meters.It is perfectly designed with over-load protection for all ranges and the unique structure, making it a superb professional meter especially for electricians.
An ideal tool for the maintenance and troubleshooting needed in metallurgy, manufacturing, petroleum, electric power, chemical industry, etc;SKU: n/a
There are no reviews yet.