TDR-420 Time Domain Reflectometer/ Cable Fault Locator

Availability:

Out of stock


Product features

  • Possibility damage-free location of impedance changes of tested cables and wires such as:
    • shorted conductor,
    • open conductor / end of cable – useful during the inventory of warehouses and stores,
    • splice,
    • splitter,
    • water ingress,
    • wet splice,
    • bridge tap
    • or other changes.
  • Single measurement mode ONCE,
  • Continuously measurement mode CONT,
  • Tone signal generator TONE,
  • Two cursors to mark two places of damage along with an indication of the distance between them,
  • Built-in HELP function for easier interpretation of the reflectogram,
  • 11 available measuring ranges from 7 m to 6000 m,
  • „dead zone” limited to 0.6 m,
  • Color 3,5” LCD TFT display with resolution 320 x 240 pixels,
  • manually set of sensitivity in 8 steps GAIN,
  • output impedance regulation up to 200 Ω (possibility of measuring pre-insulated pipes),
  • Velocity of Propagation set in range from 10% to 99%,
  • tight and durable housing with IP67 ingress protection degree.
  • Small size and weight.

0

Out of stock

Compare

TDR-420 is a hand held Time Domain Reflectometer designed to identify and locate faults in power, telecommunications and teletechnical cables. TDR-420 reflectometer allows to measure the length of the cable and determine the distance to damage or impedance variation in the range of 4 m to 6000 m in conductors with metal wires. The shortest measuring range of 7 meters and a dead zone of 0.6 meters allows to locate damages at a very close distance from the place where the device is connected.

Two cursors allow to determine the place of two damages simultaneously and the distance between them.

Thanks to the color 3,5” TFT display with a resolution of 320 x 240 pixels, the indication of the location of the damage is precise and the results easier to interpret.

Difficult environment conditions during measurement work are frequent problems encountered by electric installers and maintenance services. Thanks to the unique housing TDR-420 ensure a degree of protection on IP67 level, what means dustproof and protection against water penetration during short-term immersion. Therefore, working in very dusty terrain or accidental contact of the device with water will not affect the correct operation of the reflectometer.

 

Technical specification

  • Measurement ranges: 7, 15, 30, 60, 120, 250, 500 m, 1, 2, 3, 6 km / 20, 45, 90, 180, 360, 750, 1500, 3000, 6000, 10000, 20000 ft
  • Accuracy:1% of selected range
  • Resolution: Approx. 1% of selected range
  • Min. Cable length: 4 m / (14 ft)
  • Velocity of propagation VoP: Adjustable from 10 to…99% or 15…148,5 m/µs
  • Output Pulse: 5 Vp-p (open circuit)
  • Output Impedance: 25, 50, 75, 100, 120, 200 Ω
  • Output Impedance: 3 ns…3 µs (depends of range)
  • Scan rate / mode: Up to 3 scans / second (CONT) or single (ONCE)
  • Tone generator: 810 … 1110 Hz
  • Battery Life: Up to 8 hours of continuous scan
  • Power supply: 4 x alkaline batteries 1.5 V type AA or 4 x rechargeable batteries NiMH AA
  • Auto-OFF: 1, 3, 5, 10, 15 minutes or deactivated
  • Display: Color 3,5” LCD TFT, 320 x 240 pixels
  • Voltage protection: 400 V DC / 250 V AC
  • Dimensions: 220 x 98 x 58 mm (8.7 x 3.9 x 2.3 inches)
  • Weight: 487 g
  • Electromagnetic standard compatibility EMC: EN 61326-1
  • Water/ Dust Proof: IP67

Nominal condition of use

  • Operating temperature: -20..+70°C
  • Storage temperature: -30…+80°C at humidity <80%

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “TDR-420 Time Domain Reflectometer/ Cable Fault Locator”

There are no reviews yet.

  • Micro Lens UT-Z002

    0 out of 5
    (0)
    SKU: n/a
  • UT201+ ACA Digital Clamp Meters

    0 out of 5
    (0)

    1. Auto range and 3/s sampling rate

    2. Data hold

    3. Max value hold

    4. Auto power off

    5. Low battery prompt, over-range prompt and auto polarity display

    6. Comfortable tohold and easy to carry with (Product weight: 220g)

    7. 1m drop proof

    8. Complies with Double Insulationand Over Voltage standards of CAT II 600V, CAT III 300V and Pollution Degree 2

    9. Complies with CE (European Union) directives

    SKU: n/a
  • UTG1005A Function/Arbitrary Waveform Generator

    0 out of 5
    (0)

    1. Intuitive interface design

    2. Single channel
    3. 125MS/s sampling rate, 14-bit vertical resolution
    4. Integrated analog and digital design
    5. 4.3 inches TFT LCD
    SKU: n/a
  • UT136C+ Digital Multimeter

    0 out of 5
    (0)
    SKU: n/a
  • UT622A Digital Inductance LCR Meter

    0 out of 5
    (0)
    Specifications UT622A UT622C UT622E
    Certificates CE, RoHS
    Test frequency 100Hz, 120Hz, 1kHz, 10kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz
    Test signal level  0.1Vrms, 0.3Vrms, 1Vrms
    Output impedance 100Ω
    Measurement parameters Primary: L/C/R/Z
    Secondary: D/Q/θ/ESR
    Primary: L/C/R/Z/DCR  Secondary: D/Q/θ/ESR
    Auto LCR
    Test terminals Three-terminal test jacks, five-terminal test sockets
    Test rate Fast (20 times/s), medium (5 times/s), or slow (2 times/s)
    DCR test rate Fast (20 times/s), medium (5 times/s), or slow (2 times/s)
    Ranging mode Auto/hold
    Tolerance range 1%~20%
    Testing circuit mode Series/parallel mode
    Clearing correction Open/short circuit
    Fuse of test ports 0.1A/250V
    Communication interface Mini-USB
    LED alarm for tolerance
    (pass: green; fail: red)
    Display range
    Maximum reading 99999
    Minimum resolution 0.0001
    Maximum accuracy 0.001
    L 0.00μH~99.999H
    C 0.00pF~99.999mF
    Z/R 0.0000Ω~9.9999MΩ
    ESR 0.0000Ω~999.99Ω
    D 0.0000~9.9999
    Q 0.0000~99999
    θ -179.9°~179.9°
    DCR 0.01mΩ–20.000MΩ
    Temperature coefficient 0.1× (specified accuracy) /°C (0°C~18°C or 28°C~40°C)
    General Characteristics
    Power 3.7V 1800mAh lithium polymer battery; Input: 220V (1±10%), 50Hz (1±5%); Mini-USB output: 5V, 1A
    Display 2.8′ TFT LCD 320X240
    Product net weight 420g
    Product size 93mm x 192mm x 44mm
    Standard accessories Short circuit board (UTR-001), USB cable, 5V 1A power adapter, Four-terminal Kelvin testleads (UTR-L100k-H) (UT622C/E), Alligator clip test leads with rubber plugs (UTR-002)(UT622A), English manual
    SKU: n/a