-17%

UT18C Voltage And Continuity Testers


UT18 series of test pen with measuring AC and DC voltage (including the three-phase alternating current) measurement, phase of three-phase AC power indicator, on-off test, RCD test, single pen measurement (can determine the zero line or wire), self checking, no battery detection and other functions.
Suitable for: smelting, electronics, manufacturing, defense, electric power, petroleum, chemical industry. Also used to solve complex problems of electronic, factory automation, power distribution and electrical equipment in.

10,800 13,000

Compare

UT18 series of test pen with measuring AC and DC voltage (including the three-phase alternating current) measurement, phase of three-phase AC power indicator, on-off test, RCD test, single pen measurement (can determine the zero line or wire), self checking, no battery detection and other functions.
Suitable for: smelting, electronics, manufacturing, defense, electric power, petroleum, chemical industry. Also used to solve complex problems of electronic, factory automation, power distribution and electrical equipment in.

Category:
Weight 0.3 kg
Dimensions 27 × 9 × 3 cm
Specifications Range Best Accuracy
Model UT18C
LED AC/DC Voltage Indication (V) 12V 8V±2V
24V 18V±2V
50V 38V±4V
120V 92V±6V
230V 174V±8V
400V 320V±10V
690V 550V±15V
Phase Rotation Test Operating Voltage: 100V~690V
Frequency:50Hz~ 60Hz
Single Lead(L2)Voltage Detection Operating Voltage:100V~690V
Frequency: 50Hz~ 400Hz
Continuity Test Resistance: 0~100KΩ
Beeper and LED light Indicator
RCD Test Operating Voltage:230V(50Hz~400Hz)
Polarity Detection Positive & Negative
Self-inspection All LED or LCD indicator
No Power Test Operating Voltage: 50VAC/120VDC~690VDC/AC
Features
IP65
Auto Range All Range
Exceed Voltage Voltage Range:713V~788V
Auto standby standby current <10uA
Silent  mode All Range
Work Light All Range
Low Battery Indication Voltage Range:2.2V~2.4V
LCD Display (Voltage+frequency) 6V~ 690V (40Hz~400Hz) ±(1.5%+5)
General Characteristic 
Power 1.5V Batteries(R03) × 2
LCD Size 31×20mm
Product Color Red and Grey
Product Net Weight 280g
Product Size 272mm×85mm×31 mm
Standard Accessories Batteries
Standard Individual Packing Blister, English Manual
Standard Quantity Per Carton 30PCs
Standard Carton Measurement 440mm × 295mm × 455mm (0.079 CBM Per Standard Carton)
Standard Carton Gross Weight 17.5Kg

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT18C Voltage And Continuity Testers”

There are no reviews yet.

  • JM – Z14 Multifunctional Plastic Storage Box

    0 out of 5
    (0)

    Main Features:
    ● It can be comparted to use, suitable for different small size things
    ● The compartment is detachable, you could adjust them to storage the little stuffs as you like

    SKU: n/a
  • UT283A Single Phase Power Quality Analyzer

    0 out of 5
    (0)

    1. Trend/event capture

    2. Harmonics/inrush current measurement
    3. File management through USB interface
    4. Flick measure (PST/PLT values)
    5. User friendly interface
    6. Multimeter functions
    7. Scope functions including waveform display
    8. 3.5 inches 64K color TFT LCD display
    9. THD (Total Harmonic Distortion) function
    10.Long-term monitoring
    SKU: n/a
  • PQM-707 Power Quality Analyzer

    0 out of 5
    (0)
    • Features:

      • 7″ touch screen – intuitive operating
      • CAT IV 600V – high safety
      • all parameters acc. to class S – high accuracy of measurements
      • Li-Ion rechargeable battery – higher mobility
      • removable memory card – recording data with no restrictions

      Possible measurements:

      • Measurements according to EN 50160,
      • Voltage L1, L2, L3, N-PE (five inputs),
        – average, minimum, maximum values, range to 760 V, ability to work with voltage transformers,
      • Current L1, L2, L3, N (four inputs),
        – average, minimum, maximum values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers,
      • Crest factor for voltage and current,
      • Frequency from 40 Hz to 70 Hz ,
      • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
      • Power recording:
        • Budeanu method,
        • IEEE 1459,
      • Active, reactive, apparent energy,
      • Power factor, cosφ, tgφ,
      • Up to 50th harmonics for voltage and current,
      • Total Harmonic Distortion (THD) for voltage and current,
      • Short-term (PST) and long-term (PLT) flicker,
      • Unbalance of voltage and current,
      • Current and voltage events registration including waveforms and RMS graphs half period,
      • Inrush current
      • Calculator of energy tariffs
      • ANALYZER MEASURES AND RECORDS ACCORDING TO THE IEC 61000-4-30 CLASS S STANDARD.
    SKU: n/a
  • UT136B+ Digital Multimeter

    0 out of 5
    (0)

    1. Measures up to 1000V and 10A AC/DC voltage and current

    2. Equipped with 3mm protective sleeve; 2 meters drop proof
    3. Large LCD display; Overload alarm
    4. Quick sampling rate, up to 4 times/s
    5. Quick capacitor measurement (measures 1mF in 4 seconds)
    6. Low power consumption and auto power saving function; long battery service life (>500hrs)
    SKU: n/a
  • YH 907M IRON FOR 938

    0 out of 5
    (0)

    Yihua 907M SMD Soldering Iron Soldering Iron Tweezers for YIHUA938D 938BD+ Metal Heating Core Double Tweezers