-11%

UT213C ACA DCA Digital Clamp Meters

Availability:

20 in stock


Main Features

1. 10A/400A AC/DC measurement with Hall-effect sensor

2. Auto range makes measurement faster and more effective

3. 4000 display count, 3/s sampling rate

4. True RMS measurement

5. NCV, Non-Contact AC Voltage testing

6. Frequency and duty ratio measurement

7. MAX/MIN mode

8. Relative mode

9. Flashlight function for measuring at night or in the dark

10. K-type point contact temperature probe for temperature measurement

11. Large jaw of 30mm

12. Data hold

13. LCD backlight

14. Auto power off

15. 1m drop proof

16. Complies with CE (European Union) directives

15,600 17,440

20 in stock

Compare

Main Features

1. 10A/400A AC/DC measurement with Hall-effect sensor

2. Auto range makes measurement faster and more effective

3. 4000 display count, 3/s sampling rate

4. True RMS measurement

5. NCV, Non-Contact AC Voltage testing

6. Frequency and duty ratio measurement

7. MAX/MIN mode

8. Relative mode

9. Flashlight function for measuring at night or in the dark

10. K-type point contact temperature probe for temperature measurement

11. Large jaw of 30mm

12. Data hold

13. LCD backlight

14. Auto power off

15. 1m drop proof

16. Complies with CE (European Union) directives

Category:
Weight 0.23 kg
Dimensions 22 × 7 × 4 cm
Specifications Range Best Accuracy
Model UT213C
AC Current (A) 40A/400A ±(2.5%+5)
DC Current (A) 40A/400A ±(2.0%+3)
AC Voltage (V) 4V/40V/400V/600V ±(1.2%+5)
DC Voltage (V) 400mV/4V/40V/400V/600V ±(0.8%+1)
Resistance (Ω) 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ ±(1.0%+2)
Capacitance (F) 40nF400nF/4μF/40μF/400μF/4mF/40mF ±(4.0%+5)
Frequency (Hz) 10Hz-1MHz ±(0.1%+4)
Temperature (°C) -40 °C ~ 1000°C ±(1.0%+3)
Temperature (°F) -40℉ ~  1832℉ ±(1.0%+6)
Features
Display Count 4000
Auto Range
Jaw Capacity 30mm
True RMS
Diode √(Around 3.0V)
NCV
Data Hold
Relative Mode
MAX/MIN
LCD Backlight
Flashlight
Auto Power Off
Continuity Buzzer
Low Battery Indication ≤3.6V
Input Protection
Input Impedance for DCV ≥10MΩ
General Characteristic 
Power AAA 1.5V × 3
LCD Size 38mm × 24 mm
Product Color Red and Grey
Product Net Weight 231.7g
Product Size 220mm ×  75mm ×  40mm
Standard Accessories Batteries, Test Lead,Point Contact Temperature Probe
Standard Individual Packing Gift Box, Carrying Bag, English Manual
Standard Quantity Per Carton 40 PCs
Standard Carton Measurement 485mm × 320mm × 385mm (0.060 CBM Per Standard Carton)
Standard Carton Gross Weight 20Kg

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT213C ACA DCA Digital Clamp Meters”

There are no reviews yet.

  • YH 907M IRON FOR 938

    0 out of 5
    (0)

    Yihua 907M SMD Soldering Iron Soldering Iron Tweezers for YIHUA938D 938BD+ Metal Heating Core Double Tweezers

    SKU: n/a
  • JM-8111 33 in 1 Universal Telecommunications Screwdriver Maintenance Repair Tools

    0 out of 5
    (0)
    Features:
    33-in-1 interchangeable precise manual tool set.
    Professional portable hardware tools.
    Light weight, compact design.
    High hardness and good toughness.
    PP&TPR material, non-slip handle.
    SKU: n/a
  • UT383-BT Mini Light Meter

    0 out of 5
    (0)
    SKU: n/a
  • SOLDERING IRON SW 830L

    0 out of 5
    (0)

    SOLDERING IRON SW 830L

    SKU: n/a
  • MRU-30 Earth Resistance and Resistivity Meter

    0 out of 5
    (0)

     

    • It allows to take the measurements of:

      • earthing resistance using auxiliary electrodes,
      • earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
      • earthing resistance using double clamps for measuring multiple earthing without underground connections.
      • ground resistivity (Wenner method),
      • continuity of equipotential bondings and protective
      • conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.

      Additionally:

      • measurement of resistance of auxiliary electrodes RS and RH,
      • measurement of interference voltage,
      • measurement in the presence of interference voltage in the power network
      • with frequency 50Hz, 60Hz,
      • selection of maximum measuring voltage (25V and 50V),
      • introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
      • memory of 990 measurements (10 banks of 99 cells each),
      • calibration of clamp used,
      • data transmission to the computer (USB),
      • indication of battery state.
    SKU: n/a
  • UT362 Anemometer

    0 out of 5
    (0)

    1. Data hold, LCD backlight

    2. ℃/℉ selectable
    3. Auto power off (cancelable)
    4. 2044 sets data storage
    5. Auto record function with 0 .5~255s interval
    6. Wearproof fan shaft for improved accuracy and reliability
    7. Wind speed modes: MAX, MIN, Real-time
    8. Wind count modes: MAX, 2/3 MAX, MIN, AVG, real-time
    9. 7 selectable units: m/s, km/h, ft/min, MPH, KNOTS, CFM, CMM
    SKU: n/a