-11%

UT213C ACA DCA Digital Clamp Meters

Availability:

20 in stock


Main Features

1. 10A/400A AC/DC measurement with Hall-effect sensor

2. Auto range makes measurement faster and more effective

3. 4000 display count, 3/s sampling rate

4. True RMS measurement

5. NCV, Non-Contact AC Voltage testing

6. Frequency and duty ratio measurement

7. MAX/MIN mode

8. Relative mode

9. Flashlight function for measuring at night or in the dark

10. K-type point contact temperature probe for temperature measurement

11. Large jaw of 30mm

12. Data hold

13. LCD backlight

14. Auto power off

15. 1m drop proof

16. Complies with CE (European Union) directives

15,600 17,440

20 in stock

Compare

Main Features

1. 10A/400A AC/DC measurement with Hall-effect sensor

2. Auto range makes measurement faster and more effective

3. 4000 display count, 3/s sampling rate

4. True RMS measurement

5. NCV, Non-Contact AC Voltage testing

6. Frequency and duty ratio measurement

7. MAX/MIN mode

8. Relative mode

9. Flashlight function for measuring at night or in the dark

10. K-type point contact temperature probe for temperature measurement

11. Large jaw of 30mm

12. Data hold

13. LCD backlight

14. Auto power off

15. 1m drop proof

16. Complies with CE (European Union) directives

Category:
Weight 0.23 kg
Dimensions 22 × 7 × 4 cm
Specifications Range Best Accuracy
Model UT213C
AC Current (A) 40A/400A ±(2.5%+5)
DC Current (A) 40A/400A ±(2.0%+3)
AC Voltage (V) 4V/40V/400V/600V ±(1.2%+5)
DC Voltage (V) 400mV/4V/40V/400V/600V ±(0.8%+1)
Resistance (Ω) 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ ±(1.0%+2)
Capacitance (F) 40nF400nF/4μF/40μF/400μF/4mF/40mF ±(4.0%+5)
Frequency (Hz) 10Hz-1MHz ±(0.1%+4)
Temperature (°C) -40 °C ~ 1000°C ±(1.0%+3)
Temperature (°F) -40℉ ~  1832℉ ±(1.0%+6)
Features
Display Count 4000
Auto Range
Jaw Capacity 30mm
True RMS
Diode √(Around 3.0V)
NCV
Data Hold
Relative Mode
MAX/MIN
LCD Backlight
Flashlight
Auto Power Off
Continuity Buzzer
Low Battery Indication ≤3.6V
Input Protection
Input Impedance for DCV ≥10MΩ
General Characteristic 
Power AAA 1.5V × 3
LCD Size 38mm × 24 mm
Product Color Red and Grey
Product Net Weight 231.7g
Product Size 220mm ×  75mm ×  40mm
Standard Accessories Batteries, Test Lead,Point Contact Temperature Probe
Standard Individual Packing Gift Box, Carrying Bag, English Manual
Standard Quantity Per Carton 40 PCs
Standard Carton Measurement 485mm × 320mm × 385mm (0.060 CBM Per Standard Carton)
Standard Carton Gross Weight 20Kg

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT213C ACA DCA Digital Clamp Meters”

There are no reviews yet.

  • CMP-2000 Digital clamp-on multimeter

    0 out of 5
    (0)

    It provides:

    • AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
    • Measurement of INRUSH current in start-up phase of electrical device.
    • AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
    • Resistance measurement and continuity test:
      – continuity test with acoustic signalling (beeper) for resistance below 30 Ω.
    • Capacitance measurement.
    • Temperature measurement (Fahrenheit or Celsius).
    • Frequency measurement.
    • Duty cycle measurement.
    • Diode test.
    SKU: n/a
  • JM-6108 Ratchet Screwdriver Bits Set

    0 out of 5
    (0)

     

    Features:

    • Ratchet screwdrivers with twist reverse and ratchet lock mechanism.
    • Contoured comfort grip handle. Supplied in storage case.
    • 180 degrees angle ratchet screwdriver.
    • Forward & Reverse with locking action.
    • Adjustable screwdriver bits for different screws.
    • Common used in automotive parts and home appliances.
    SKU: n/a
  • UT207B 1000A True RMS Digital Clamp Meter

    0 out of 5
    (0)

    1. Flashlight button: Short press thisbutton to turn on/off the flashlight.
    2. Flexible current probe (optional) to extendthe AC current measurement range to3000A
    3. Inrush current capture
    4. NCV Multi-Segment Display and audio/visual alarm
    5. True RMS/Auto backlight
    6. NCV/Function retention

    SKU: n/a
  • TKF-12 Phase Sequence Tester

    0 out of 5
    (0)

    Phase sequence indication (direction of field rotation) in the power network with rated phase-to-phase voltage (120…690 V) AC by LED signalization.
    Operation in the power network with frequency range 10…70 Hz.

    Indication of the voltage presence in the particular phases by neon lamps signalization.
    Power supply from the tested network (continuous operation to 15 minutes for max. voltage).
    Protection against faulty indication of field rotation.

    SKU: n/a
  • UT601 Inductance Capacitance Meters

    0 out of 5
    (0)

    UT600 series RCL meter is a kind of 3.5-bithandheld digital meter with stable performance, safety, reliability, highaccuracy and manual range. It can be used to measure the magnification times β of audion, diode forward voltage drop and circuit continuity. UT601has wide capacitance measurement range from 0.1pF~20mF and highaccuracy. UT602 can hold data. UT 600 series is applicable to testingresistance, capacitance and inductance of electronic laboratory, productionline, maintenance point and teaching. It is the ideal tool of maintaining formany users

    SKU: n/a
  • UT516B Insulation Resistance Tester

    0 out of 5
    (0)

    Features of UT516B Insulation Resistance Tester

    ● AC/DC voltage

    ● USB data transfer
    ● Low battery indication
    ● Data storage
    ● LCD backlight
    ● Polarization Index
    ● Over-range alarm
    ● 9999 Max display
    ● Comparative measurement
    ● Measurement time selection
    SKU: n/a