UT230B series power sockets can be inserted to monitor operation status (voltage, current, time, and power consumption) of electrical appliances. The socket jacks are designed to meet the needs of different regions with proper certifications. UT230B series are ideal tools for maintaining equipment power consumption and managing energy saving in homes, offices, schools, and other places.
Weight | 0.2 kg |
---|---|
Dimensions | 12 × 6 × 4 cm |
Specifications | Range | UT230B-UK |
Voltage | 100V~260V | ±1% |
Current | 0A~13A | ±1% |
Frequency | 45Hz~65Hz | √ |
Power | 1~2990W | ±1% |
Power factor | 0~1 | ±2% |
Energy consumption | 0~9999kWh | ±1% |
Features | ||
Unit price of electricity | 0~99.99 ($/kWh) | √ |
Accumulative time | 0 minute~9999 days | √ |
Accumulative charge | 0~9999$ | √ |
CO2 display | 0~9999kg | √ |
Power consumption | <0.4W | √ |
Overload indication | >13A | |
General Characterisitics | ||
Power | 3V button battery | |
Display | 48mm x 30.5mm | |
Product color | White | |
Product net weight | 155g | |
Product size | 130mm x 65mm x 37mm | |
Standard accessories | Battery | |
Standard individual packing | Blister, English manual | |
Standard quantity per carton | 80pcs | |
Standard carton measurement | 570mm x 400mm x 360mm | |
Standard carton gross weight | 19.6kg |
Based on 0 reviews
Be the first to review “UT230B-EU Power Socket”
-
Power Quality Analyzer
PQM-707 Power Quality Analyzer
-
Features:
- 7″ touch screen – intuitive operating
- CAT IV 600V – high safety
- all parameters acc. to class S – high accuracy of measurements
- Li-Ion rechargeable battery – higher mobility
- removable memory card – recording data with no restrictions
Possible measurements:
- Measurements according to EN 50160,
- Voltage L1, L2, L3, N-PE (five inputs),
– average, minimum, maximum values, range to 760 V, ability to work with voltage transformers, - Current L1, L2, L3, N (four inputs),
– average, minimum, maximum values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers, - Crest factor for voltage and current,
- Frequency from 40 Hz to 70 Hz ,
- Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
- Power recording:
- Budeanu method,
- IEEE 1459,
- Active, reactive, apparent energy,
- Power factor, cosφ, tgφ,
- Up to 50th harmonics for voltage and current,
- Total Harmonic Distortion (THD) for voltage and current,
- Short-term (PST) and long-term (PLT) flicker,
- Unbalance of voltage and current,
- Current and voltage events registration including waveforms and RMS graphs half period,
- Inrush current
- Calculator of energy tariffs
- ANALYZER MEASURES AND RECORDS ACCORDING TO THE IEC 61000-4-30 CLASS S STANDARD.
SKU: n/a -
-
Voltage Detector
UT12D-US AC Voltage Detector
features:
1. Auto power off
2. Buzzer
3. LED indication
4. AC voltagedetection
5. High/Low voltagemodeApplications:
Low voltage mode: Low-voltage motor (<90V), audio systems, arc welding machines,underground mining lighting, cables with thick insulation layer and other weakelectromagnetic AC signals.
High voltage mode: Urban electric supply and three-phase systems (90~1000V). Forexample, power distribution units, electrical panels, electrical appliances.SKU: n/a -
Phase Detector Meters
TKF-12 Phase Sequence Tester
Phase sequence indication (direction of field rotation) in the power network with rated phase-to-phase voltage (120…690 V) AC by LED signalization.
Operation in the power network with frequency range 10…70 Hz.
Indication of the voltage presence in the particular phases by neon lamps signalization.
Power supply from the tested network (continuous operation to 15 minutes for max. voltage).
Protection against faulty indication of field rotation.SKU: n/a
There are no reviews yet.