UT258A is well designed for on-line measurement of DC/AC leakage current and current below 600V, which adopts latest CT and digital integration technology. Slender clamp is very suitable for places full of concentrated cables (such as, electric power metering system, high-speed rail system, automobile circuit maintenance and so on). Non-contact measurement ensures operation safety. The meter has mini shape with high accuracy, stable performance and perfect functions.
₨30,000 ₨31,000
2 in stock
CompareWeight | 0.2 kg |
---|---|
Dimensions | 17 × 6 × 3 cm |
General Functions | Range | Accuracy |
Type | UT258A | |
Current (A) | 0mA~60.0A AC/DC | ±(2%+5) |
Resolution | 1mA AC/DC | |
Frequency Response | AC: 45HZ~200HZ | |
Special Functions | ||
Display Mode | 4-bit LCD display | √ |
Jaw Size | φ7mm (max wires O.D.) | √ |
Auto Range | √ | |
RS-232 Data Transmission | √ | |
Data Storage | 99 groups | |
Zero Adjustment | Press ZERO to return to zero, remove residual magnetism induction, and then clamp the wires to be tested. | √ |
Data Hold | √ | |
Line Voltage | not beyond 600V | √ |
Auto Power Off | 5 min | √ |
Low Battery Indication | Indicates low battery when the voltage is 7.2 | √ |
Sampling Rate | About 2 sec per time | √ |
Working Current | 10mA | √ |
General Characteristics | ||
Power Supply | Zinc-manganese battery 6F22 9V | |
Product Color | Red and grey | |
Product Weight | 180g (with batteries) | |
Product Size | 168mm×65mm×34mm | |
Standard Accessories | Batteries, monitoring software, RS232 cable | |
Standard Package | Gift box, user manual, toolbox | |
Standard Package Quantity | 40pcs | |
Standard Package Size | 540X365X290mm | |
Standard Package Gross Weight | 20kg |
Based on 0 reviews
Be the first to review “UT258A AC/DC Leakage Clamp Meter”
-
Clamp Meters
AC/DC DIGITAL CLAMP METER KEW 2046R
• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Very useful for power distribution companies, power utilities and maintenance fields.
• True RMS enables an accurate measurement.SKU: n/a -
Multimeters
ET 8102 DMM
Specifications:
Model:ET8102
Display:5999 Counts
Color:Black
DC Voltage:6V/60V/600V±(0.5%+3),1000V±(0.8%+10)
AC Voltage:6V/60V/600V±(0.8%+3),750V±(1.2%+10)
DC Current:600uA/6000uA/60mA/600mA±(1.2%+10),6A/10A±(2.0%+30)
AC Current:600uA/6000uA/60mA/600mA±(1.2%+10),6A/10A±(2.0%+30)
Resistance:600Ω±(0.8%+5),6KΩ/60KΩ/600KΩ/6MΩ±(0.8%+3),40MΩ±(2.5%+3)
Capacitance:60nF/600nF/6μF/60μF/600μF±(3.5%+20),6mF/30mF±(5.0%+3)
Frequency:10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz±(0.1%+3)
Temperature:-20℃~1000℃,±(1.0%+5)<400℃,±(1.5%+15)≥400℃
0℉~1832℉,±(0.75%+5)<750℉,±(1.5%+15)≥750℃
NCV test:Yes
Zero line/fire wire:Yes
Duty cycle:Yes
Diode test:Yes
Continuity testing:Yes
Backlight:Yes
Date hold:Yes
True RMS:Yes
Max/Min value measurement:Yes
Flashlight:Yes
Auto power off:Yes
Low battery indication:Yes
Over range indication:Yes
Power:2 x 1.5V AAA Battery (not included)
Product Size:142 x 68 x 32 mm
Product Net Weight:187gPackage Information:
Package Size:16.5 x 10 x 5cm / 6.5 x 3.9 x 2in
Package Weight:295g / 10.4 ozPackage list:
1 x Digital Multimeter
2 x Test Leads Pens
1 x User Manual
• 1.Multifunction:Can measure AC/DC voltage,AC/DC current,resistance,capacitance,
• 2.Portable design:Small and can be put into pocket,easy to carry.
• 3.Wide range of applications:It’s a perfect tool for the laboratory,factory and home.
• 4.Easy to use & clear to read:With large LCD backlight display and flashlight function,convenient to read data in dark.
• frequency,duty cycle,temperature,NCV,diode,continuity,zero line/fire wire.SKU: n/a -
Insulation Tester
MIC-5001, 5000V Insulation Tester
Insulation resistance measurement in a compact, light-weight, low-cost design.
- Measurement to 5 TΩ
- Measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps
- Continuous indication of insulation resistance or leakage current
- Automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement
- Audio beeps every five seconds to alert user test is proceeding, and to get time characteristics
- Measured test times of T1, T2 and T3 for measuring Absorption Coefficient, Dielectric Absorption Ratio DAR. and Polarization Index PI
- Continuous display of test voltage during the measurement
- Protection against measuring live objects
- Two and three-lead measurement method
- Ramp Test Insulation resistance measurement
- Measurement of breakdown voltage with increments up to 1 kV / s
- Measurement of alternating and direct voltages from 0 V to 750 V
- 990 cells of memory (11880 records) to record results
- Data transfer to PC via USB cable
- Built-in rechargeable battery pack
- Meets the requirements of the EN 61557 standard
- Charge from optional car lighter (12 V) socket accessory