Portable digital multimeter UNIT UT70B with advanced design. Photoelectric separation guarentees absolutely secure galvanic isolation of multimeter from PC. … DC Voltage: 400mV / 4V / 40V / 400V / 1000V.

14,544 15,794

20 in stock

Compare

Portable digital multimeter UNIT UT70B with advanced design. Photoelectric separation guarentees absolutely secure galvanic isolation of multimeter from PC. … DC Voltage: 400mV / 4V / 40V / 400V / 1000V.

Category:
Weight 0.6 kg
Dimensions 19 × 9 × 4 cm
Specifications Range Best Accuracy
Model UT70B
DC Voltage (V) 400mV/4V/40V/400V/1000V ±(0.8%+1)
AC Voltage(V) 4V/40V/400V/750V ±(1%+5)
DC Current (A) 400mA/4000mA/40mA/400mA/10A ±(1%+2)
AC Current (A) 400mA/4000mA/40mA/400mA/10A ±(1.5%+5)
Resistance (Ω) 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ ±(1%+2)
Capacitance (F) 4nF/40nF/400nF/4μF/40μF/400μF/4μF/40μF ±(4%+3)
Frequency 4kHz/40kHz/400kHz/4MHz/40MHz/400MHz ±(0.1%+3)
Temperture(°C) -40℃~1000℃ ±(1%+3)
Temperture(°F) -40℉~1832℉ ±(1%+4)
RPM 40kRPM ±(0.1%+3)
Features
Fused 10A Range
Diode
Continuity Buzzer
Relative measurement
Full Icon Display
Sleep Mode
Low Battery Display
Input Impedance for DC Voltage Measurement 10MΩ
Max/Min Mode
Peak Hold
Data Hold
Display Backlight
Auto Ranging
Max. Display 3999
RS232
Analog Bar Graph 41
General Characteristic 
Power 9V Battery (6F22)
LCD Size 62mm×53mm
Product Color Red and Grey
Product Net Weight 600g (including holster)
Product Size 195mm×90mm×40mm
Standard Accessories Test Lead, Battery, English Manual, Point Contact Temperature Probe, Test Clip, RS232C Interface Cable, Software, Holster
Optional Accessories* Clip-On Test Lead Light (UT-TL), Built-In Test Lead Light (UT-L1), Built-In Test Lead Light Plus (UT-L2), Carrying Bag

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT70B Modern Digital Multi-Purpose Meters”

There are no reviews yet.

  • UT300A+ Infrared Thermometer

    0 out of 5
    (0)

    1. Simple one button operation

    2. 10:1 D:S ratio
    3. Data hold
    4. Backlight
    5. Temperature range: -20℃~400℃
    SKU: n/a
  • LKZ-720 Wires and pipe locator

    0 out of 5
    (0)

    Features:

    • the function 3D in the receiver – detecting the direction of current flow and accurate locating the object,
    • phase detection mode,
    • receiver operation with four transmitters at the same time to locate interruptions or distinguish wires,
    • a LED bright torch,
    • headphone socket in receiver,
    • screens backlight for work in dark,
    • transmission battery status and settings of the transmitter to the receiver
    • operation in wide range of rated voltage, up to 500V RMS,
    •  measurement of voltage at the object to 500 Vrms,
    • three levels of transmitter amplification,
    • automatic or manual selection of transmitter operation modes,
    • five modes of wire tracer operation – voltage, current, current-voltage, power and clamp,
    • software upgrade via USB,
    • additional accessories enable precise localization – such as contact or non-contact probes and measurement clamp.
    SKU: n/a
  • UT13A/UT13B AC Voltage Detectors-Adjustable Sensitivity (220V/110V) (Discontinued)

    0 out of 5
    (0)

    Features of UT13A/UT13B AC Voltage Detectors-Adjustable Sensitivity (220V/110V)

    Certifications: CE, RoHS, UL

    ● Complies with CAT IV 600V (UT13A); prevent damage caused by transient voltage
    ● CAT IV 1000V (UT13B)
    ● LED indication
    ● Vibration indication (UT13B)
    ● Adjustable sensitivity

    SKU: n/a
  • UNI-T MSO3154E 150MHz Mixed Signal 4 Channel Digital Oscilloscope

    0 out of 5
    (0)
    Analog bandwidth 150MHz 250MHz
    Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital
    Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels)
    Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels)
    Memory depth 70Mpts
    Waveform capture rate 200,000wfms/s
    Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display )
    Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall]
    Input impedance (1MΩ±1%) II (20pF±3pF)
    Input impedance digital (101kΩ±1%) II (9pF±1pF)
    Vertical scale 1mV/div~20 V/div (1 MΩ)
    DC gain accuracy <5mV: ±3%, ≥5mV: ±2%
    Waveform record 100,000 frames
    Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
    CAN, LIN, FlexRay
    Bus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay
    Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations
     

     

    Auto measurements

    Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
    -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
    channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A
    Measurement display 5 types
    Measurement statistics Average, Max, Min, standard deviation and number of measurements
    Frequency counter 6 bits
    Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA
     

     

    Standard Accessories

    USB interface cable UT-D14
    Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06
    Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05
    16CH Logic analyzer probe UT-15M

     

    SKU: n/a
  • MIC-15k1 ,15kV Insulation Quality Analyzer

    0 out of 5
    (0)

     

    Features:

    • Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD, widened with thepartial discharge (PD) indicator for every each of these measurements.
    • It allows testing the electrical durability of the tested object – breakdown voltage indication.
    • High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and close to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
    • The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility and to carry out a partial location of their occurrence.
    • Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
      • visual method (if power cables are visible along the entire length),
      • reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault (the conductor must be buried in the ground with earth direct contact).
    • Compatible with external software.