Portable digital multimeter UNI–T UT70B with advanced design. Photoelectric separation guarentees absolutely secure galvanic isolation of multimeter from PC. … DC Voltage: 400mV / 4V / 40V / 400V / 1000V.
Multimeters
UT70B Modern Digital Multi-Purpose Meters
Availability:
20 in stock
Portable digital multimeter UNI–T UT70B with advanced design. Photoelectric separation guarentees absolutely secure galvanic isolation of multimeter from PC. … DC Voltage: 400mV / 4V / 40V / 400V / 1000V.
₨14,544 ₨15,794
20 in stock
CompareWeight | 0.6 kg |
---|---|
Dimensions | 19 × 9 × 4 cm |
Specifications | Range | Best Accuracy |
Model | UT70B | |
DC Voltage (V) | 400mV/4V/40V/400V/1000V | ±(0.8%+1) |
AC Voltage(V) | 4V/40V/400V/750V | ±(1%+5) |
DC Current (A) | 400mA/4000mA/40mA/400mA/10A | ±(1%+2) |
AC Current (A) | 400mA/4000mA/40mA/400mA/10A | ±(1.5%+5) |
Resistance (Ω) | 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ | ±(1%+2) |
Capacitance (F) | 4nF/40nF/400nF/4μF/40μF/400μF/4μF/40μF | ±(4%+3) |
Frequency | 4kHz/40kHz/400kHz/4MHz/40MHz/400MHz | ±(0.1%+3) |
Temperture(°C) | -40℃~1000℃ | ±(1%+3) |
Temperture(°F) | -40℉~1832℉ | ±(1%+4) |
RPM | 40kRPM | ±(0.1%+3) |
Features | ||
Fused 10A Range | √ | |
Diode | √ | |
Continuity Buzzer | √ | |
Relative measurement | √ | |
Full Icon Display | √ | |
Sleep Mode | √ | |
Low Battery Display | √ | |
Input Impedance for DC Voltage Measurement | 10MΩ | √ |
Max/Min Mode | √ | |
Peak Hold | ||
Data Hold | √ | |
Display Backlight | √ | |
Auto Ranging | √ | |
Max. Display | 3999 | |
RS232 | √ | |
Analog Bar Graph | 41 | √ |
General Characteristic | ||
Power | 9V Battery (6F22) | |
LCD Size | 62mm×53mm | |
Product Color | Red and Grey | |
Product Net Weight | 600g (including holster) | |
Product Size | 195mm×90mm×40mm | |
Standard Accessories | Test Lead, Battery, English Manual, Point Contact Temperature Probe, Test Clip, RS232C Interface Cable, Software, Holster | |
Optional Accessories* | Clip-On Test Lead Light (UT-TL), Built-In Test Lead Light (UT-L1), Built-In Test Lead Light Plus (UT-L2), Carrying Bag |
Based on 0 reviews
Be the first to review “UT70B Modern Digital Multi-Purpose Meters”
-
Wire & Cable Testers
LKZ-720 Wires and pipe locator
Features:
- the function 3D in the receiver – detecting the direction of current flow and accurate locating the object,
- phase detection mode,
- receiver operation with four transmitters at the same time to locate interruptions or distinguish wires,
- a LED bright torch,
- headphone socket in receiver,
- screens backlight for work in dark,
- transmission battery status and settings of the transmitter to the receiver
- operation in wide range of rated voltage, up to 500V RMS,
- measurement of voltage at the object to 500 Vrms,
- three levels of transmitter amplification,
- automatic or manual selection of transmitter operation modes,
- five modes of wire tracer operation – voltage, current, current-voltage, power and clamp,
- software upgrade via USB,
- additional accessories enable precise localization – such as contact or non-contact probes and measurement clamp.
SKU: n/a -
Voltage Detector
UT13A/UT13B AC Voltage Detectors-Adjustable Sensitivity (220V/110V) (Discontinued)
Features of UT13A/UT13B AC Voltage Detectors-Adjustable Sensitivity (220V/110V)
Certifications: CE, RoHS, UL
● Complies with CAT IV 600V (UT13A); prevent damage caused by transient voltage
● CAT IV 1000V (UT13B)
● LED indication
● Vibration indication (UT13B)
● Adjustable sensitivitySKU: n/a -
Oscilloscopes
UNI-T MSO3154E 150MHz Mixed Signal 4 Channel Digital Oscilloscope
Analog bandwidth 150MHz 250MHz Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels) Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) Memory depth 70Mpts Waveform capture rate 200,000wfms/s Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display ) Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall] Input impedance (1MΩ±1%) II (20pF±3pF) Input impedance digital (101kΩ±1%) II (9pF±1pF) Vertical scale 1mV/div~20 V/div (1 MΩ) DC gain accuracy <5mV: ±3%, ≥5mV: ±2% Waveform record 100,000 frames Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
CAN, LIN, FlexRayBus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations Auto measurements
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
-Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→AMeasurement display 5 types Measurement statistics Average, Max, Min, standard deviation and number of measurements Frequency counter 6 bits Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA Standard Accessories
USB interface cable UT-D14 Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06 Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05 16CH Logic analyzer probe UT-15M SKU: n/a -
Insulation Tester
MIC-15k1 ,15kV Insulation Quality Analyzer
Features:
- Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD, widened with thepartial discharge (PD) indicator for every each of these measurements.
- It allows testing the electrical durability of the tested object – breakdown voltage indication.
- High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and close to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
- The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility and to carry out a partial location of their occurrence.
- Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
- visual method (if power cables are visible along the entire length),
- reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault (the conductor must be buried in the ground with earth direct contact).
- Compatible with external software.
SKU: n/a