-22%

UT890C+ TRMS Digital Multimeter

Availability:

19 in stock


1.6000 Counts; Measure voltage and current RMS.

2.The capacitance slot has REL function. Range is from 1pF to 99.99mF
3.The device can measure frequency of high accuracy. The min resolution is 0.001Hz

4.It has special functions: MAX/MIN and MAX-MIN
5.The min DC and AC resolution is 0.01μA and 1μA. The max range is 20A.
6.It can measure diode  whose voltage drop is up to 3V .So it is very suitable to measure LED.
7.It has functions: hold, power off and backlight.
8.It also measure temperature ℃ and ℉

4,600 5,914

19 in stock

Compare

1.6000 Counts; Measure voltage and current RMS.

2.The capacitance slot has REL function. Range is from 1pF to 99.99mF
3.The device can measure frequency of high accuracy. The min resolution is 0.001Hz

4.It has special functions: MAX/MIN and MAX-MIN
5.The min DC and AC resolution is 0.01μA and 1μA. The max range is 20A.
6.It can measure diode  whose voltage drop is up to 3V .So it is very suitable to measure LED.
7.It has functions: hold, power off and backlight.
8.It also measure temperature ℃ and ℉

Category:
Weight 0.4 kg
Dimensions 18 × 9 × 6 cm
Basic functions Range Basic accuracy
Model  UNI-T UT890C + UT890D
DC voltage V 600.0mV (0.5% + 4) (0.5% + 4)
6.000V / 60.00V / 600.0V (0.5% + 2) (0.5% + 2)
1000V (0.7% + 10) (0.7% + 10)
AC voltage V 6.000V / 60.00V / 600.0V (0.8% + 3) (0.8% + 3)
750V (1.0% + 10) (1.0% + 10)
AC current A 6.000mA / 60.00mA (1.0% + 12) (1.0% + 12)
600.0mA (2.0% + 3) (2.0% + 3)
20.00A (3.0% + 5) (3.0% + 5)
A direct current 60.00A / 6.000mA / 60.00mA (0.8% + 8) (0.8% + 8)
600.0mA (1.2% + 5) (1.2% + 5)
20.00A (2.0% + 5) (2.0% + 5)
Resistance 600.0 (0.8% + 5) (0.8% + 5)
6.000k / 60.00k / 600.0k / 6.000M (0.8% + 3) (0.8% + 3)
60.00M (1.0% + 25) (1.0% + 25)
Temperature ℃ -400 ℃ ~ 1000 ℃ (1.0% + 3)
Temperature ℉ -40 ℉ ~ 1832 ℉ (1.5% + 5)
Capacitance F 6.000nF (5.0% + 35) (5.0% + 35)
60.00nF ~ 600.0F (2.5% + 20) (2.5% + 20)
6000F (5.0% + 10) (5.0% + 10)
Frequency Hz 9.999Hz ~ 9.999MHz (0.1% + 5) (0.1% + 5)
Measuring range: 10Hz ~ 10MHz (auto range), 100kHz:100mVrms input amplitude 30Vrms,
> 100kHz ~ 1MHz:200mVrms input amplitude 30Vrms, > 1MHz:600mVrms input amplitude 30Vrms
Special features
Max / Min
True RMS measurement TRMS
Frequency response Applicable sine wave and triangular wave,
200Hz other waveforms for reference
40Hz ~ 1kHz
Diode test
Continuity Buzzer
hFE
REL
Data Hold
LCD backlight
Battery voltage tips
Automatic shutdown About 15 minutes
Input impedance 10M
General Characteristics
Environment 18 C ~ 28 C (64 F ~ 82 F); relative humidity: 75%
Battery 9V battery (6F22)(Not included)
LCD size 63mm × 29mm
Colors Red + Grey
Body weight 300g
Dimensions 186mm × 91mm × 39mm
Standard accessories Table pen, temperature probe (onlyUT890C +)

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT890C+ TRMS Digital Multimeter”

There are no reviews yet.

  • JM OP018 OPENING TOOL

    0 out of 5
    (0)
    SKU: n/a
  • MECHANIC RD Series lead-free ESD soldering tip 900M-T-IS

    0 out of 5
    (0)

    MECHANIC RD Series lead-free ESD soldering tip 900M-T-IS

    Good heat conduction, fast heating, corrosion resistance, antistatic,long service life

    SKU: n/a
  • UT725 Multifunction Process Calibrator

    0 out of 5
    (0)

    Features of UT725 Multifunction Process Calibrator

    Certifications: CE, UKCA

    ● Step/ramp functions

    ● Source and measure accuracy up to 0.02%
    ● Rechargeable battery
    ● Contrast adjustment
    ● Auto power off (Time adjustable)
    ● Stores and recalls setups
    ● USB communication
    ● Simultaneously measure and output different process signal in real time
    ● Pressure measure with specified pressure modules, and sourcing pressure
    ● Provides 24V loop power to transmitter while conducting mA current measurement at the same time
    SKU: n/a
  • UT533 Insulation Multimeter

    0 out of 5
    (0)

    Features of UT533 Insulation Multimeter

    Certifications: CE, RoHS

    ● AC/DC voltage measurement

    ● AC/DC current measurement
    ● Insulation resistance measurement
    ● Resistance & Capacity test

    ● Frequency & Temperature test

    ● 1000V output voltage
    ● Double insulation design
    SKU: n/a
  • CLAMP METER AC BM 2000B

    0 out of 5
    (0)

    SPECIFICATIONS:

    – Maximum display: 1999
    – Method indication: LCD
    – Maximum arm span: 60mm
    – Operating temperature range:
    work: 0C – 40C
    Storage:-10C – 60C
    – Power supply: 9V battery
    – Low battery indication: YES, graphic symbol
    – Audible indication: YES, piezoelectric transducer
    – Dimensions: 270x100x45 mm
    – Weight: about 610g (with battery)

    Features
    – Measuring voltage: 0-1000V 2 range
    – Measurement of AC voltage: 0-700V in 1 range
    – Measurement of alternating current: 200A-2000A in 2 ranges
    – Measuring current: 200A-2000A in 2 ranges
    – Measurement of resistance: 2k in 1 range
    – Measuring capacity: NO
    – Frequency: NO
    – Temperature measurement: NO
    – Testing LEDs: YES
    – Acoustic continuity tester: YES
    – Distance between arms: 6cm
    – Meter dimensions: 270x100x45 mm
    – Weight: 610g with battery
    – Basic accuracy: ± (0.5% +2 digits)

    Packages Include:

    1 × Clamp-On Meter BM-2000B

    An internal link is any link from one page on your website to another page on your website. Both your users and search engines use links to find content on your website. Your users use links to navigate through your site and to find the content they want to find. Search engines also use links to navigate your site. They won’t find a page if there are no links to it. There are several types of internal links. In addition to links on your homepage,mean post feed, etc, you can also add links within your content. We call those contextual links. Contextual links point your users to interesting and related content.
    SKU: n/a