-22%

UT890C+ TRMS Digital Multimeter

Availability:

19 in stock


1.6000 Counts; Measure voltage and current RMS.

2.The capacitance slot has REL function. Range is from 1pF to 99.99mF
3.The device can measure frequency of high accuracy. The min resolution is 0.001Hz

4.It has special functions: MAX/MIN and MAX-MIN
5.The min DC and AC resolution is 0.01μA and 1μA. The max range is 20A.
6.It can measure diode  whose voltage drop is up to 3V .So it is very suitable to measure LED.
7.It has functions: hold, power off and backlight.
8.It also measure temperature ℃ and ℉

4,600 5,914

19 in stock

Compare

1.6000 Counts; Measure voltage and current RMS.

2.The capacitance slot has REL function. Range is from 1pF to 99.99mF
3.The device can measure frequency of high accuracy. The min resolution is 0.001Hz

4.It has special functions: MAX/MIN and MAX-MIN
5.The min DC and AC resolution is 0.01μA and 1μA. The max range is 20A.
6.It can measure diode  whose voltage drop is up to 3V .So it is very suitable to measure LED.
7.It has functions: hold, power off and backlight.
8.It also measure temperature ℃ and ℉

Category:
Weight 0.4 kg
Dimensions 18 × 9 × 6 cm
Basic functions Range Basic accuracy
Model  UNI-T UT890C + UT890D
DC voltage V 600.0mV (0.5% + 4) (0.5% + 4)
6.000V / 60.00V / 600.0V (0.5% + 2) (0.5% + 2)
1000V (0.7% + 10) (0.7% + 10)
AC voltage V 6.000V / 60.00V / 600.0V (0.8% + 3) (0.8% + 3)
750V (1.0% + 10) (1.0% + 10)
AC current A 6.000mA / 60.00mA (1.0% + 12) (1.0% + 12)
600.0mA (2.0% + 3) (2.0% + 3)
20.00A (3.0% + 5) (3.0% + 5)
A direct current 60.00A / 6.000mA / 60.00mA (0.8% + 8) (0.8% + 8)
600.0mA (1.2% + 5) (1.2% + 5)
20.00A (2.0% + 5) (2.0% + 5)
Resistance 600.0 (0.8% + 5) (0.8% + 5)
6.000k / 60.00k / 600.0k / 6.000M (0.8% + 3) (0.8% + 3)
60.00M (1.0% + 25) (1.0% + 25)
Temperature ℃ -400 ℃ ~ 1000 ℃ (1.0% + 3)
Temperature ℉ -40 ℉ ~ 1832 ℉ (1.5% + 5)
Capacitance F 6.000nF (5.0% + 35) (5.0% + 35)
60.00nF ~ 600.0F (2.5% + 20) (2.5% + 20)
6000F (5.0% + 10) (5.0% + 10)
Frequency Hz 9.999Hz ~ 9.999MHz (0.1% + 5) (0.1% + 5)
Measuring range: 10Hz ~ 10MHz (auto range), 100kHz:100mVrms input amplitude 30Vrms,
> 100kHz ~ 1MHz:200mVrms input amplitude 30Vrms, > 1MHz:600mVrms input amplitude 30Vrms
Special features
Max / Min
True RMS measurement TRMS
Frequency response Applicable sine wave and triangular wave,
200Hz other waveforms for reference
40Hz ~ 1kHz
Diode test
Continuity Buzzer
hFE
REL
Data Hold
LCD backlight
Battery voltage tips
Automatic shutdown About 15 minutes
Input impedance 10M
General Characteristics
Environment 18 C ~ 28 C (64 F ~ 82 F); relative humidity: 75%
Battery 9V battery (6F22)(Not included)
LCD size 63mm × 29mm
Colors Red + Grey
Body weight 300g
Dimensions 186mm × 91mm × 39mm
Standard accessories Table pen, temperature probe (onlyUT890C +)

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT890C+ TRMS Digital Multimeter”

There are no reviews yet.

  • TITAN TN 305DS DC Power Supply

    0 out of 5
    (0)

    Operating Conditions

    Supply power: AC 220-240V, 50Hz/60Hz.

    Working Temperature: -10°C ~ 40 °C

    Relative Humidity: ‹ 90%

    Storage Conditions: -10°C ~ 40 °C

    Relative Humidity: ‹ 80%

    Stable Voltage

    The output voltage is between 0 and nominal value continuously adjustable

    Voltage Stability: ≤0.01% +2mV

    Load Stability: ≤ 0.01% +2mV

    Recovery Time: ≤100µS

    Temperature Coefficient: ≤ 200PPM/°C

    Ripple Noise: ≤1 MVRMS(RMS)
    Stable Current

    Power Stability: 0.1% + 3mA

    Load Stability: 0.2% + 3mA

    Ripple Noise : ≤2mArms(RMS)

    The output current is between 0 and nominal value continuously adjustable

    SKU: n/a
  • UT622A Digital Inductance LCR Meter

    0 out of 5
    (0)
    Specifications UT622A UT622C UT622E
    Certificates CE, RoHS
    Test frequency 100Hz, 120Hz, 1kHz, 10kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz
    Test signal level  0.1Vrms, 0.3Vrms, 1Vrms
    Output impedance 100Ω
    Measurement parameters Primary: L/C/R/Z
    Secondary: D/Q/θ/ESR
    Primary: L/C/R/Z/DCR  Secondary: D/Q/θ/ESR
    Auto LCR
    Test terminals Three-terminal test jacks, five-terminal test sockets
    Test rate Fast (20 times/s), medium (5 times/s), or slow (2 times/s)
    DCR test rate Fast (20 times/s), medium (5 times/s), or slow (2 times/s)
    Ranging mode Auto/hold
    Tolerance range 1%~20%
    Testing circuit mode Series/parallel mode
    Clearing correction Open/short circuit
    Fuse of test ports 0.1A/250V
    Communication interface Mini-USB
    LED alarm for tolerance
    (pass: green; fail: red)
    Display range
    Maximum reading 99999
    Minimum resolution 0.0001
    Maximum accuracy 0.001
    L 0.00μH~99.999H
    C 0.00pF~99.999mF
    Z/R 0.0000Ω~9.9999MΩ
    ESR 0.0000Ω~999.99Ω
    D 0.0000~9.9999
    Q 0.0000~99999
    θ -179.9°~179.9°
    DCR 0.01mΩ–20.000MΩ
    Temperature coefficient 0.1× (specified accuracy) /°C (0°C~18°C or 28°C~40°C)
    General Characteristics
    Power 3.7V 1800mAh lithium polymer battery; Input: 220V (1±10%), 50Hz (1±5%); Mini-USB output: 5V, 1A
    Display 2.8′ TFT LCD 320X240
    Product net weight 420g
    Product size 93mm x 192mm x 44mm
    Standard accessories Short circuit board (UTR-001), USB cable, 5V 1A power adapter, Four-terminal Kelvin testleads (UTR-L100k-H) (UT622C/E), Alligator clip test leads with rubber plugs (UTR-002)(UT622A), English manual
    SKU: n/a