Product Features 1. 6000 Counts 2. True RMS voltage and current measurements 3. Capacitance, Resistance, Buzzer, Diode 4. Capacitance with REL function, resolution is 1pF, maximum measurement range is 6000μF 5. Highly accurate frequency measurement function; minimum resolution is 0.001Hz 6. MAX\MIN and MAX-MIN value 7. DC current minimum resolution is 0.01 A, AC current minimum resolution is 1μA, maximum range is 20A 8. HOLD function,backlight and auto power off function
UT890D Digital Multimeter
20 in stock
Product Features 1. 6000 Counts 2. True RMS voltage and current measurements 3. Capacitance, Resistance, Buzzer, Diode 4. Capacitance with REL function, resolution is 1pF, maximum measurement range is 6000μF 5. Highly accurate frequency measurement function; minimum resolution is 0.001Hz 6. MAX\MIN and MAX-MIN value 7. DC current minimum resolution is 0.01 A, AC current minimum resolution is 1μA, maximum range is 20A 8. HOLD function,backlight and auto power off function
₨4,560 ₨5,491
20 in stock
CompareWeight | 0.35 kg |
---|---|
Dimensions | 18 × 9 × 6 cm |
Specifications | Range | Accuracy |
DC current(V) | 600.0mV | ±(0.5%+4) |
6.000V/60.00V/600.0V | ±(0.5%+2) | |
1000V | ±(0.7%+10) | |
AC current(V) | 6.000V/60.00V/600.0V | ±(0.8%+3) |
750V | ±(1.0%+10) | |
AC Current(A) | 6.000mA/60.00mA | ±(1.0%+12) |
600.0mA | ±(2.0%+3) | |
20.00A | ±(3.0%+5) | |
DC Current(A) | 60.00μA/6.000mA/60.00mA | ±(0.8%+8) |
600.0mA | ±(1.2%+5) | |
20.00A | ±(2.0%+5) | |
Resistance(Ω) | 600.0Ω | ±(0.8%+5) |
6.000kΩ/60.00kΩ/600.0kΩ/6.000MΩ | ±(0.8%+3) | |
60.00MΩ | ±(1.0%+25) | |
Capacitance(F) | 9.999nF | ±(5.0%+35) |
99.99nF~999.9μF | ±(2.5%+20) | |
9.999mF | ±(5.0%+10) | |
99.99mF | 10mF≤C≤20mF | |
±(10.0%+5) | ||
Frequency(Hz) | 9.999Hz~9.999MHz | ±(0.1%+5) |
Measurement range: 10Hz~10MHz(Auto Range), ≤100kHz∶100mVrms≤Input amplitude≤30Vrms,>100kHz~1MHz∶200mVrms≤Input amplitude≤30Vrms,>1MHz∶600mVrms≤Input amplitude≤30Vrms | ||
MAX/MIN | √ | |
True RMS | √ | |
Frequency Response | Applies to sine wave and triangular wave, ≥200Hz, other waveforms are for reference | 40Hz~1kHz |
Diode Test | √ | |
hFE | √ | |
Continuity Test | √ | |
REL | √ | |
Data Hold | √ | |
Backlight Adjustment | √ | |
Battery Voltage Indicator | √ | |
Auto Power Off | Around 15 Minutes | √ |
Input Impedance For DCV | ≥10MΩ | √ |
General Characteristics | ||
Use Environment | 18℃~28℃(64℉~82℉) Relative Temperature | |
Battery | 9V Battery(6F22) | |
LCD size | 63mm × 29mm | |
Product Color | Red and Grey | |
Product Net Weight | 300g | |
Product Size | 186mm × 91mm × 39mm | |
Standard Accessories | Test Leads, Battery | |
Standard Individual Packing | Gift Box, Instructions, Warranty Card | |
Standard Quantity Per Carton | 40PC | |
Standard Individual Packing Size | 645mm × 450mm × 340mm | |
Standard Carton Gross Weight | 22.8 Kg |
Based on 0 reviews
Be the first to review “UT890D Digital Multimeter”
-
Laser Distance Meters
LM 60 T Laser Tapes
Features of LM T Series Laser Tapes
Certificates: CE, UKCA
LM40T:
● One-button operation
● Single measurement
● Rear measurement reference
● Unit conversion
● Dual measurement methods
● Portable and compactLM60T:
● Single measurement
● Dual measurement mode● Portable and compact
● Continuous measurementSKU: n/a -
-
Oscilloscopes
UNI-T MSO3254E 250MHz Mixed Signal 4 Channel Digital Oscilloscope
Analog bandwidth 150MHz 250MHz Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels) Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) Memory depth 70Mpts Waveform capture rate 200,000wfms/s Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display ) Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall] Input impedance (1MΩ±1%) II (20pF±3pF) Input impedance digital (101kΩ±1%) II (9pF±1pF) Vertical scale 1mV/div~20 V/div (1 MΩ) DC gain accuracy <5mV: ±3%, ≥5mV: ±2% Waveform record 100,000 frames Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
CAN, LIN, FlexRayBus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations Auto measurements
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
-Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→AMeasurement display 5 types Measurement statistics Average, Max, Min, standard deviation and number of measurements Frequency counter 6 bits Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA Standard Accessories
USB interface cable UT-D14 Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06 Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05 16CH Logic analyzer probe UT-15M SKU: n/a -
Clamp Meters
UT216A 600A Digital Clamp Meters
UT216 series true RMS digital clamp meter is a new-generation practical electrotechnical measurement meter which has the features of high reliability, high safety, automatic range and handheld type, has full-range overload protection and unique appearance design, is more excellent in performance, and is an ideal tool for detection, maintenance and repair of various universities and colleges, smelting, communication, manufacturing, petroleum, national defense, electrical, power and circuit equipment.
UTD216A (main features)- 1、600A AC current measurement
- 2、True RMS response for ACV and ACA
- 3、99.99mF capacitance measurement
- 4、Non-contact voltage detection with LED indication
- 5、Flashlight for working at dark environment
SKU: n/a -
Oscilloscopes
UNI-T MSO3152E 150MHz Mixed Signal 2 Channel Digital Oscilloscope
Analog bandwidth 150MHz 250MHz Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels) Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) Memory depth 70Mpts Waveform capture rate 200,000wfms/s Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display ) Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall] Input impedance (1MΩ±1%) II (20pF±3pF) Input impedance digital (101kΩ±1%) II (9pF±1pF) Vertical scale 1mV/div~20 V/div (1 MΩ) DC gain accuracy <5mV: ±3%, ≥5mV: ±2% Waveform record 100,000 frames Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
CAN, LIN, FlexRayBus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations Auto measurements
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
-Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→AMeasurement display 5 types Measurement statistics Average, Max, Min, standard deviation and number of measurements Frequency counter 6 bits Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA Standard Accessories
USB interface cable UT-D14 Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06 Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05 16CH Logic analyzer probe UT-15M SKU: n/a -
There are no reviews yet.