-13%

YH-305D DC Power Supply


  • Model: YH-305D
  • Compact Design
  • All Metal Construction
  • Dual LED Three Digital Tube Display
  • Current mA / A Conversion Display
  • High Stabilized Output Voltage
  • Short Circuit Protection
  • Over Loading and Current Protection
  • CE Approved

13,000 14,936

Compare

YIHUA 305D  DC power supply

1.This model has compact design with all metal construction.

2.This unit now features a Dual LED three digital tube

  1. Display with highly accurate LED digital readout.

4.Maximum output is 30V at 5A.

  1. High stabilized output voltage.
  2. Current mA / A conversion display.

7.Short circuit protection.

8.Over loading and current protection.

9.CE Approved

Category:
Weight 4 kg
Dimensions 13 × 25 × 15 cm

Operating Conditions

Supply power: AC 220-240V, 50Hz/60Hz.

Working Temperature: -10°C ~ 40 °C

Relative Humidity: ‹ 90%

Storage Conditions: -10°C ~ 40 °C

Relative Humidity: ‹ 80%

Stable Voltage

The output voltage is between 0 and nominal value continuously adjustable

Voltage Stability: ≤0.01% +2mV

Load Stability: ≤ 0.01% +2mV

Recovery Time: ≤100µS

Ripple Noise: ≤1 MVRMS(RMS)

Temperature Coefficient: ≤ 200PPM/°C

Stable Current

The output current is between 0 and nominal value continuously adjustable

Power Stability: 0.1% + 3mA

Load Stability: 0.2% + 3mA

Ripple Noise : ≤2mArms(RMS)

Brand

YIHUA

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “YH-305D DC Power Supply”

There are no reviews yet.

  • RF-0.5x New

    0 out of 5
    (0)

    RF-0.5x New

    SKU: n/a
  • YH 816D IRON

    0 out of 5
    (0)
    SKU: n/a
  • UNI-T UT3513 DC Resistance Tester Microohmmeter 4.3 Inch LCD Screen Cable/Coil/Motor Resistance Test

    0 out of 5
    (0)
    Model UT3513
    Resistance range 20m Q/200m Q/2Q/20Q /200 Q/2kQ/20kQ
    Resolution 1 u Q/10 u Q/100 u Q/lmO/lOmQ/lOOmQ/1 Q/10Q/100Q
    Test current 1A/1A/100mA/10mA/1mA/1mA/100 uA/10 u A/l uA
    Testing terminal opencircuit voltage <1V/<1V/<1V/<1V/<5V/<5V/<5V/<5V/<3V/
    Measured parameter DC resistance
    Basic accuracy Slow: 0. 1%; Medium: 0. 2%
    Maximum reading 22000
    Range mode Auto/Manual/nominal
    Calibration Short-circuit full range zeroing
    Sorting function 3types of resistance and voltage input: exceeds upper limit/exceeds lower limit/within the range,2 types of sorting result output: PASS/FAIL
    Comparing method Absolute tolerance, percentage tolerance, direct-reading comparison
    Trigger mode Internal, external
    Test terminal Four-terminal measurement
    Button functions Lock 一一 keyboard lock, OK 一一 screenshot
    System setup Language: Chinese/English, key tone setting
    Interfaces & protocols Handler interface, RS232, USB DEVICE and USB HOST communication interface,SCPI and Modbus protocol
    Upper computer software V
    Power AC 100~240V 50/60Hz
    Display 4.3-inches LCD
    SKU: n/a
  • UT395C Professional Laser Distance Meter

    0 out of 5
    (0)

    UT395 series are professional laser distance meters with color LCD display, electronic multi-axis leveler and other special features. Its unique operating system, friendly user interface, and personalized settings option all make these devices the perfect choice for professional distance measurement.

    SKU: UN39C5T
  • Pride Cutter Plier 6″ With Rubber Grip Handle

    0 out of 5
    (0)

    Pride Cutter Plier 6″ With Rubber Grip Handle

    SKU: n/a
  • MRU-30 Earth Resistance and Resistivity Meter

    0 out of 5
    (0)

     

    • It allows to take the measurements of:

      • earthing resistance using auxiliary electrodes,
      • earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
      • earthing resistance using double clamps for measuring multiple earthing without underground connections.
      • ground resistivity (Wenner method),
      • continuity of equipotential bondings and protective
      • conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.

      Additionally:

      • measurement of resistance of auxiliary electrodes RS and RH,
      • measurement of interference voltage,
      • measurement in the presence of interference voltage in the power network
      • with frequency 50Hz, 60Hz,
      • selection of maximum measuring voltage (25V and 50V),
      • introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
      • memory of 990 measurements (10 banks of 99 cells each),
      • calibration of clamp used,
      • data transmission to the computer (USB),
      • indication of battery state.