Multimeters
UNI T Bench Top Digital Multimeter UT8803E
- 20,000 Count EBTN LCD Display
- DC Voltage: 200mV/2V/20V/200V/1000V
- AC Voltage: 2V/20V/200V/750V
- DC Current: 200μA/2mA/20mA/200mA/20A
- AC Current: 2mA/20mA/200mA/20A
- Resistance: 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/200MΩ
- Capacitance: 20nF/200nF/2μF/20μF/200μF/2mF/20mF/100mF
- Frequency: 200Hz~10MHz
- Duty cycle: 5%~99%
- Frequency response: 1 kHz
- USB Interface
- Data hold
- MAX/MIN
- Continuity buzzer
- Diode/transistor
- test
- CAT II 600V
SKU: n/a -
-
Insulation Tester
MIC-2501,2500V Insulation Resistance Meter
Electrical safety:
- type of insulation: double, in acc. with EN 61010-1 und IEC 61557
- measurement category: IV 600 V (III 1000 V) in acc. to EN 61010-1
- case protection rating in acc. with EN 60529: IP65
Other technical specifications:
- power supply of the meter SONEL L-1 NiMH 9,6 V; DC 12 V 2,5 A
- weight of the meter: approx. 0,9 kg
- dimensions: 200 x 180 x 77 mm
- display: LCD segment display
- measurement results memory: 990 cells, 11880 records,
- transmission of measurement results: USB
SKU: n/a -
-
Power Quality Analyzer
PQM-707 Power Quality Analyzer
-
Features:
- 7″ touch screen – intuitive operating
- CAT IV 600V – high safety
- all parameters acc. to class S – high accuracy of measurements
- Li-Ion rechargeable battery – higher mobility
- removable memory card – recording data with no restrictions
Possible measurements:
- Measurements according to EN 50160,
- Voltage L1, L2, L3, N-PE (five inputs),
– average, minimum, maximum values, range to 760 V, ability to work with voltage transformers, - Current L1, L2, L3, N (four inputs),
– average, minimum, maximum values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers, - Crest factor for voltage and current,
- Frequency from 40 Hz to 70 Hz ,
- Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
- Power recording:
- Budeanu method,
- IEEE 1459,
- Active, reactive, apparent energy,
- Power factor, cosφ, tgφ,
- Up to 50th harmonics for voltage and current,
- Total Harmonic Distortion (THD) for voltage and current,
- Short-term (PST) and long-term (PLT) flicker,
- Unbalance of voltage and current,
- Current and voltage events registration including waveforms and RMS graphs half period,
- Inrush current
- Calculator of energy tariffs
- ANALYZER MEASURES AND RECORDS ACCORDING TO THE IEC 61000-4-30 CLASS S STANDARD.
SKU: n/a -