-24%

CLAMP METER AC CM 2007


Specification of the item

3,335 4,360

Compare

HTC CM-2007 600A AC Clamp Meter with Temp Frequence

  • Digital Clamp meter DC Voltage: 400mV/4V/40V/400V/600V; Resolution: 0.1mV/1mV/ 10mV/100mV/1V; Accuracy: � 1.0% + 5 digits/ � 0.5% + 5 digits
  • AC Voltage: 400mV/4V/40V/400V/600V; Resolution: 0.1mV/1mV/10mV/100mV/1V; Accuracy: �1.5% + 5 digits/ � 1.0% + 5 digits
  • AC Current: 400A to 600A; Resolution: 100mA to 1A; Accuracy: <40A �3.0% + 5 digits/ >40A �2.0% + 5 digits
  • Resistance: 400 ohm/4k?/40k?/400k?/4M?/40M?; Resolution: 0.1?/1?/ 10?/ 100M?/1k?/10 k?; Accuracy: � 0.8% + 5 digit/� 0.8% + 3 digits/� 1.2% + 5 digits
  • Capacitance: 4nF/40nF/400nF/4?F//40?F /200?F; Resolution: 1pF/10pF/100pF/1nF/10nF/100nF; Accuracy: � 5.0% + 20 digit/� 3.5% + 00 digit/� 5.0% + 10 digit
  • Frequency Range (Hz): 100Hz to 10mHz; Resolution: 0.01Hz to 1kHz; Accuracy: /� 0.5% + 5 digits/Accessories: CM-2000 Digital Clamp meter, Instruction Manual, Test Lead, Soft Caring Case / Power: AAA 1.5 x 2
Category:

Brand

China Brand

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CLAMP METER AC CM 2007”

There are no reviews yet.

  • MIC-5001, 5000V Insulation Tester

    0 out of 5
    (0)

    Insulation resistance measurement in a compact, light-weight, low-cost design.

    • Measurement to 5 TΩ
    • Measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps
    • Continuous indication of insulation resistance or leakage current
    • Automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement
    • Audio beeps every five seconds to alert user test is proceeding, and to get time characteristics
    • Measured test times of T1, T2 and T3 for measuring Absorption Coefficient, Dielectric Absorption Ratio DAR. and Polarization Index PI
    • Continuous display of test voltage during the measurement
    • Protection against measuring live objects
    • Two and three-lead measurement method
    • Ramp Test Insulation resistance measurement
    • Measurement of breakdown voltage with increments up to 1 kV / s
    • Measurement of alternating and direct voltages from 0 V to 750 V
    • 990 cells of memory (11880 records) to record results
    • Data transfer to PC via USB cable
    • Built-in rechargeable battery pack
    • Meets the requirements of the EN 61557 standard
    • Charge from optional car lighter (12 V) socket accessory
    SKU: n/a
  • TITAN TN 305DS DC Power Supply

    0 out of 5
    (0)

    Operating Conditions

    Supply power: AC 220-240V, 50Hz/60Hz.

    Working Temperature: -10°C ~ 40 °C

    Relative Humidity: ‹ 90%

    Storage Conditions: -10°C ~ 40 °C

    Relative Humidity: ‹ 80%

    Stable Voltage

    The output voltage is between 0 and nominal value continuously adjustable

    Voltage Stability: ≤0.01% +2mV

    Load Stability: ≤ 0.01% +2mV

    Recovery Time: ≤100µS

    Temperature Coefficient: ≤ 200PPM/°C

    Ripple Noise: ≤1 MVRMS(RMS)
    Stable Current

    Power Stability: 0.1% + 3mA

    Load Stability: 0.2% + 3mA

    Ripple Noise : ≤2mArms(RMS)

    The output current is between 0 and nominal value continuously adjustable

    SKU: n/a
  • YH 134B 110 ELEMENT

    0 out of 5
    (0)
    SKU: n/a