-8%

CMP-1006 Digital Clamp-on multimeter

Availability:

5 in stock


 

Additionally:

  • safe, insulated measuring clamps,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • DC ZERO mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored zero value,
  • MAX/MIN function,
  • over range indication,
  • AUTO-OFF function.

31,587 34,221

5 in stock

Compare

(TRUE RMS) up to 1000 A.

Measurement of INRUSH current in start-up phase of electrical device (high frequency of sampling)

AC/DC voltage measurement (TRUE RMS) up to 600 V.

Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 40.

Temperature measurement (Fahrenheit and Celsius units).

Frequency measurement.

Duty cycle measurement.

Diode test.

Category:
Weight 0.3 kg
Dimensions 23 × 8 × 5 cm

Electric security:

  • measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

 

Other technical data:

  • power supply: 9 V battery type 6LR61
  • display: 6600 counts, backlit LCD
  • continuity test: threshold 40 Ω; test current < 0,5 mA
  • diode test: test current of 0,3 mA, typical open circuit voltage < 3 V DC, typical
  • low battery indication: BAT displayed
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • INRUSH: integration time 100 ms
  • temperature sensor: type K thermocouple
  • input impedance: 10 MΩ (V DC and V AC)
  • AC bandwidth: 50…400 Hz (A AC and V AC)
  • auto power OFF: approx. 25 min.
  • dimensions: 229 x 80 x 49 mm
  • weight: 303 g
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
  • quality standard: ISO 9001

 

Rated operational conditions:

  • internal clamp diameters: d1 = 36 mm/d2 = 52 mm
  • operating temperature: +5…+40°C
  • storage temperature: -20…+60°C
  • operating humidity: max 80% up to 31°C decreasing linearly to 50% at 40°C
  • storage humidity: <80%
  • operating altitude: max 2000 m

 

AC/DC current measurement (TRUE RMS)

Range Resolution Accuracy (DC) Accuracy (AC)
0…659,9 A 0,1 A ±(2,5% m.v. +5 dgt) ±(2,5% m.v + 8 dgt) for f = 50…60 Hz
660…1000 A 1 A ±(2,8% m.v. +8 dgt) ±(2,8% m.v. + 8 dgt) for f = 50…60 Hz

 

DC voltage measurement

Range Resolution Accuracy
0…6,599 V 0,001 V ±(1,5% m.v. + 3 dgt)
6,60…65,99 V 0,01 V ±(1,5% m.v. + 3 dgt)
66,0…600,0 V 0,1 V ±(1,5% m.v. + 3 dgt)

 

AC voltage measurement (TRUE RMS)

Range Resolution Accuracy
0…6,599 V 0,001 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz
6,60…65,99 V 0,01 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz
66,0…600,0 V 0,1 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz

 

Resistance measurement

Range Resolution Accuracy
0,0…659,9 Ω 0,1 Ω ±(1,0% m.v. + 4 dgt)
0,660…6,599 kΩ 0,001 kΩ ±(1,5% m.v. + 2 dgt)
6,60…65,99 kΩ 0,01 kΩ ±(1,5% m.v. + 2 dgt)
66,0…659,9 kΩ 0,1 kΩ ±(1,5% m.v. + 2 dgt)
0,660…6,599 MΩ 0,001 MΩ ±(2,5% m.v. + 3 dgt)
6,60…66,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 dgt)

 

Frequency measurement

Range Resolution Accuracy
30,0…999,9 Hz 0,1 Hz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle
1,000…9,999 kHz 0,001 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle
10,00…15,00 kHz 0,01 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle

 

Temperature measurement

Range Resolution Accuracy
-20…760°C 0,1°C ±(3,0% m.v. + 5°C)
-4…1400°F 0,1°F ±(3,0% m.v. + 9°F)

 

Duty cycle measurement

Range Resolution Accuracy
10,0…94,9% 0,1% ±(1,2% m.v. + 2 dgt)
  • pulse width: 100μs…100 ms,
  • frequency range: 30 Hz…5 kHz,
  • sensitivity: 30 Hz…5 kHz: 10 Vrms, 5 kHz…15 kHz: 40 Vrms.

 

„m.v.”- measured value

 

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-1006 Digital Clamp-on multimeter”

There are no reviews yet.

  • TDGC 500VA

    0 out of 5
    (0)

    Input Voltage=220V/230V
    Output Voltage=0-250V
    Maximum Output Current=2
    Copper Wind
    LCD Output Display

    SKU: n/a
  • UT381 illuminometers

    0 out of 5
    (0)

    UT380 series professional pocket type illuminometer has the features of high integration level, low power dissipation and high test precision. It can test light intensity from 0 to 20000 Lux. UT382 can communicate with PC, which real time stores and analyzes data.  It can also transmit the data stored in the illuminometer to computer, which analyzes, prints and saves the data. It is applicable to illumination site test. It is the best choice to measure plaza, gym, waiting hall and business site.

     

    SKU: n/a
  • PQM-707 Power Quality Analyzer

    0 out of 5
    (0)
    • Features:

      • 7″ touch screen – intuitive operating
      • CAT IV 600V – high safety
      • all parameters acc. to class S – high accuracy of measurements
      • Li-Ion rechargeable battery – higher mobility
      • removable memory card – recording data with no restrictions

      Possible measurements:

      • Measurements according to EN 50160,
      • Voltage L1, L2, L3, N-PE (five inputs),
        – average, minimum, maximum values, range to 760 V, ability to work with voltage transformers,
      • Current L1, L2, L3, N (four inputs),
        – average, minimum, maximum values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers,
      • Crest factor for voltage and current,
      • Frequency from 40 Hz to 70 Hz ,
      • Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
      • Power recording:
        • Budeanu method,
        • IEEE 1459,
      • Active, reactive, apparent energy,
      • Power factor, cosφ, tgφ,
      • Up to 50th harmonics for voltage and current,
      • Total Harmonic Distortion (THD) for voltage and current,
      • Short-term (PST) and long-term (PLT) flicker,
      • Unbalance of voltage and current,
      • Current and voltage events registration including waveforms and RMS graphs half period,
      • Inrush current
      • Calculator of energy tariffs
      • ANALYZER MEASURES AND RECORDS ACCORDING TO THE IEC 61000-4-30 CLASS S STANDARD.
    SKU: n/a
  • UT213C ACA DCA Digital Clamp Meters

    0 out of 5
    (0)

    Main Features

    1. 10A/400A AC/DC measurement with Hall-effect sensor

    2. Auto range makes measurement faster and more effective

    3. 4000 display count, 3/s sampling rate

    4. True RMS measurement

    5. NCV, Non-Contact AC Voltage testing

    6. Frequency and duty ratio measurement

    7. MAX/MIN mode

    8. Relative mode

    9. Flashlight function for measuring at night or in the dark

    10. K-type point contact temperature probe for temperature measurement

    11. Large jaw of 30mm

    12. Data hold

    13. LCD backlight

    14. Auto power off

    15. 1m drop proof

    16. Complies with CE (European Union) directives

    SKU: n/a