-25%

CMP-400 Digital Clamp-On Multimeter

Availability:

5 in stock


Additionally:

  • safe, insulated measuring clamps,
  • double molded housing,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • REL function,
  • over range indication,
  • AUTO-OFF function.

11,844 15,794

5 in stock

Compare

DC current measurement (CMP-401 only) and AC current.

AC/DC voltage measurement up to 600 V.
Resistance measurement and continuity test:
  • continuity test with acoustic signalling (beeper) for resistance below 50.

Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Diode test.

Category:
Weight 0.2 kg
Dimensions 20 × 7 × 4 cm

Temperature measurement

Range Accuracy
-20,0…760°C ±(3% m.v. + 5°C)
-4,0…1400°F ±(3% m.v. + 9°F)

*probe (K type) accuracy not included

 

Frequency measurement

Range Accuracy
-10 Hz ±(1,5% m.v. + 2 dgt)
  • sensitivity: 100 V (<50 Hz), 50 V (50…400 Hz); 15 V (401 Hz…10 kHz)

 

AC current measurement

Range Resolution Accuracy
4,000 A 0,001 A ±(2,5% m.v. + 12 dgt)
40,00 A 0,01 A ±(2,5% m.v. + 8 dgt)
400,0 A 0,1 A ±(2,8% m.v. + 8 dgt)
  • frequency range: 50…60 Hz.

 

AC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(1,5% m.v. + 30 dgt)
4,000 V 0,001 V ±(1,8% m.v. + 8 dgt)
40,00 V 0,01 V ±(1,8% m.v. + 8 dgt)
400,0 V 0,1 V ±(1,8% m.v. + 8 dgt)
600 V 1 V ±(2,5% m.v. + 8 dgt)
  • frequency range: 50 Hz…400 Hz

 

DC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(0,8% m.v. + 2 dgt)
4,000 V 0,001 V ±(1,5% m.v. + 2 dgt)
40,00 V 0,01 V ±(1,5% m.v. + 2 dgt)
400,0 V 0,1 V ±(1,5% m.v. + 2 dgt)
600 V 1 V ±(2% m.v. + 2 dgt)

 

Resistance measurement

Range Resolution Accuracy
400,0 Ω 0,1 Ω ±(1,0% m.v + 4 dgt)
4,000 kΩ 0,001 kΩ ±(1,5% m.v. + 2 dgt)
40,00 kΩ 0,01 kΩ ±(1,5% m.v. + 2 dgt)
400,0 kΩ 0,1 kΩ ±(1,5% m.v. + 2 dgt)
4,000 MΩ 0,001 MΩ ±(2,5% m.v. + 3 dgt)
40,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 dgt)

 

„m.v.”- measured value

Electric security:
– measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
– protection class acc. to EN 60529: IP40

Other technical data:
– power supply: 9 V battery type 6LR61
– display: 4000 counts, backlit LCD
– continuity test: I<0,5 mA, sound signal for R<50 Ω
– diode test: I = 0,3 mA, U0 = 1,5 V DC
– over range indication: 0L displayed
– sampling rate: 2 times per second
– input impedance: 10 MΩ (V DC and V AC)
– clamp size: opening 30 mm (1,2”)
– auto power OFF: approx. 30 min.
– dimensions: 197 x 70 x 40 mm
– weight: 183 g
– accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
– quality standard ISO 9001

Rated operational conditions:
– operating temperature: 0…+40°C
– storage temperature: -20…+60°C
– operating humidity: max 80% up to 31°C
decreasing linearly to 50% at 40°C
– operating altitude: max 2000 m

 

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-400 Digital Clamp-On Multimeter”

There are no reviews yet.

  • UT258A AC/DC Leakage Clamp Meter

    0 out of 5
    (0)

    UT258A is well designed for on-line measurement of DC/AC leakage current and current below 600V, which adopts latest CT and digital integration technology. Slender clamp is very suitable for places full of concentrated cables (such as, electric power metering system, high-speed rail system, automobile circuit maintenance and so on). Non-contact measurement ensures operation safety. The meter has mini shape with high accuracy, stable performance and perfect functions.

    SKU: n/a
  • UNI-T MSO3152E 150MHz Mixed Signal 2 Channel Digital Oscilloscope

    0 out of 5
    (0)
    Analog bandwidth 150MHz 250MHz
    Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital
    Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels)
    Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels)
    Memory depth 70Mpts
    Waveform capture rate 200,000wfms/s
    Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display )
    Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall]
    Input impedance (1MΩ±1%) II (20pF±3pF)
    Input impedance digital (101kΩ±1%) II (9pF±1pF)
    Vertical scale 1mV/div~20 V/div (1 MΩ)
    DC gain accuracy <5mV: ±3%, ≥5mV: ±2%
    Waveform record 100,000 frames
    Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
    CAN, LIN, FlexRay
    Bus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay
    Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations
     

     

    Auto measurements

    Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
    -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
    channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A
    Measurement display 5 types
    Measurement statistics Average, Max, Min, standard deviation and number of measurements
    Frequency counter 6 bits
    Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA
     

     

    Standard Accessories

    USB interface cable UT-D14
    Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06
    Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05
    16CH Logic analyzer probe UT-15M

     

    SKU: n/a
  • UNI-T UPO3354E

    0 out of 5
    (0)
    SKU: n/a