  • safe, insulated measuring clamps,
  • double molded housing,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • REL function,
  • over range indication,
  • AUTO-OFF function.

11,844 15,794

5 in stock

Compare

DC current measurement (CMP-401 only) and AC current.

AC/DC voltage measurement up to 600 V.
Resistance measurement and continuity test:
  • continuity test with acoustic signalling (beeper) for resistance below 50.

Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Diode test.

Category:
Weight 0.2 kg
Dimensions 20 × 7 × 4 cm

Temperature measurement

Range Accuracy
-20,0…760°C ±(3% m.v. + 5°C)
-4,0…1400°F ±(3% m.v. + 9°F)

*probe (K type) accuracy not included

 

Frequency measurement

Range Accuracy
-10 Hz ±(1,5% m.v. + 2 dgt)
  • sensitivity: 100 V (<50 Hz), 50 V (50…400 Hz); 15 V (401 Hz…10 kHz)

 

AC current measurement

Range Resolution Accuracy
4,000 A 0,001 A ±(2,5% m.v. + 12 dgt)
40,00 A 0,01 A ±(2,5% m.v. + 8 dgt)
400,0 A 0,1 A ±(2,8% m.v. + 8 dgt)
  • frequency range: 50…60 Hz.

 

AC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(1,5% m.v. + 30 dgt)
4,000 V 0,001 V ±(1,8% m.v. + 8 dgt)
40,00 V 0,01 V ±(1,8% m.v. + 8 dgt)
400,0 V 0,1 V ±(1,8% m.v. + 8 dgt)
600 V 1 V ±(2,5% m.v. + 8 dgt)
  • frequency range: 50 Hz…400 Hz

 

DC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(0,8% m.v. + 2 dgt)
4,000 V 0,001 V ±(1,5% m.v. + 2 dgt)
40,00 V 0,01 V ±(1,5% m.v. + 2 dgt)
400,0 V 0,1 V ±(1,5% m.v. + 2 dgt)
600 V 1 V ±(2% m.v. + 2 dgt)

 

Resistance measurement

Range Resolution Accuracy
400,0 Ω 0,1 Ω ±(1,0% m.v + 4 dgt)
4,000 kΩ 0,001 kΩ ±(1,5% m.v. + 2 dgt)
40,00 kΩ 0,01 kΩ ±(1,5% m.v. + 2 dgt)
400,0 kΩ 0,1 kΩ ±(1,5% m.v. + 2 dgt)
4,000 MΩ 0,001 MΩ ±(2,5% m.v. + 3 dgt)
40,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 dgt)

 

„m.v.”- measured value

Electric security:
– measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
– protection class acc. to EN 60529: IP40

Other technical data:
– power supply: 9 V battery type 6LR61
– display: 4000 counts, backlit LCD
– continuity test: I<0,5 mA, sound signal for R<50 Ω
– diode test: I = 0,3 mA, U0 = 1,5 V DC
– over range indication: 0L displayed
– sampling rate: 2 times per second
– input impedance: 10 MΩ (V DC and V AC)
– clamp size: opening 30 mm (1,2”)
– auto power OFF: approx. 30 min.
– dimensions: 197 x 70 x 40 mm
– weight: 183 g
– accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
– quality standard ISO 9001

Rated operational conditions:
– operating temperature: 0…+40°C
– storage temperature: -20…+60°C
– operating humidity: max 80% up to 31°C
decreasing linearly to 50% at 40°C
– operating altitude: max 2000 m

 

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-400 Digital Clamp-On Multimeter”

There are no reviews yet.

  • TDR-410 Cable Fault Locator

    0 out of 5
    (0)
    • Features:

      • automatic or manual mode:
        • the automatic fault location (AFL),
        • mode with manual range selection and sensitivity,
        • single measurement triggered manually or scanning continuous,
      • 11 available ranges from 7 m to 4000 m selected in manual mode or matched automatically,
      • maximum length of cable up to 4000 m one end of the cable,
      • “Dead zone” measure limited to 0.5 m,
      • 2.5 “LCD screen with backlight,
      • scan automatically or manually trigger,
      • sensitivity set manually or automatically adjusted,
      • adjustable impedance matching,
      • propagation coefficient adjustment 1% to 99%,
      • waterproof and resistant to mechanical housing.
      • small size and weight.
      • economical power system – 30 hours of continuously scan on one battery set..

      Accessories:

      • 0,6 m double-wire lead: WAPRZ0X6DZBB
      • red crocodile clip: WAKRORE20K02
      • Krokodylek czarny: WAKROBL20K01
      • cover M-2: WAFUTM2
    SKU: n/a
  • DIGITAL INSULATION / CONTINUITY TESTER MODEL 3005A

    0 out of 5
    (0)

    • Bargraph to display insulation resistance.
    • Displays the value of external AC voltage along with flashing symbol.
    • Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
    • Live circuit warning beeper.
    • Releasing the test button automatically discharges the charges stored in the circuit under test.
    • 200mA continuity measuring current to IEC 61557.
    • Minimum 1mA current on insulation tests to IEC 61557.

    SKU: n/a
  • UT383 – Mini Light Meter

    0 out of 5
    (0)

    UT383 is a mini light meter equipped with photoelectric sensing technology, which can effectively represent light intensity with electrical signals, then processes data and displays the result on LCD. It is light weight, compact, ergonomic, and user friendly, making it a great tool for monitoring light intensity in homes, offices, schools, laboratories, indoor farming, hospitals, and other areas.