-11%

CMP-401 Digital Clamp-on multimeter

Availability:

5 in stock


Additionally:

  • safe, insulated measuring clamps,
  • double molded housing,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • REL function,
  • over range indication,

AUTO-OFF function.

25,664 28,956

5 in stock

Compare

DC current measurement and AC current.
AC/DC voltage measurement up to 600 V.Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 50.

Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Capacitance measurement .
Diode test.

Category:
Weight 0.2 kg
Dimensions 20 × 7 × 4 cm

DC current measurement and AC current. .
AC/DC voltage measurement up to 600 V.

Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 50 Ω.

Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Capacitance measurement 
Diode test.
Additionally:

  • safe, insulated measuring clamps,
  • double molded housing,
  • autoranging/manual range selection,
  • „DATA HOLD” function, for holding measured values,
  • backlit LCD,
  • „REL” function,
  • over range indication,
  • „AUTO-OFF” function.

Electric security:

  • measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

Other technical data:

  • power supply: 9 V battery type 6LR61
  • display: 4000 counts, backlit LCD
  • continuity test: I<0,5 mA, sound signal for R<50 Ω
  • diode test: I = 0,3 mA, U0 = 1,5 V DC
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • input impedance: 10 MΩ (V DC and V AC)
  • clamp size: opening 30 mm (1,2”)
  • auto power OFF: approx. 30 min.
  • dimensions: 197 x 70 x 40 mm
  • weight: 183 g
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
  • quality standard: ISO 9001

Rated operational conditions:

  • operating temperature: 0…+40°C
  • storage temperature: -20…+60°C
  • operating humidity: max 80% up to 31°C; decreasing linearly to 50% at 40°C
  • operating altitude: max 2000 m

 

Temperature measurement

Range Accuracy*
-20,0…760°C ±(3% m.v. + 5°C)
-4,0…1400°F ±(3% m.v. + 9°F)

*probe (K type) accuracy not included

 

Frequency measurement

Range Accuracy
10 Hz … 10 kHz ±(1,5% m.v. + 2 digits)
  • csensitivity: 100 V (<50 Hz), 50 V (50…400 Hz); 15 V (401 Hz…10 kHz)

 

AC current measurement

Range Resolution Accuracy
40,00 A 0,01 A ±(2,5% m.v. + 8 digits)
400,0 A 0,1 A ±(2,8% m.v. + 5 digits)
  • frequency range: 50…60 Hz.

 

DC current measurement

Range Resolution Accuracy
40,00 A 0,01 A ±(2,5% m.v. + 5 digits)
400,0 A 0,1 A ±(2,8% m.v. + 5 digits)

 

AC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(1,5% m.v. + 30 digits)
4,000 V 0,001 V ±(1,5% m.v. + 5 digits)
40,00 V 0,01 V ±(1,5% m.v. + 5 digits)
400,0 V 0,1 V ±(1,5% m.v. + 5 digits)
600,0 V 1 V ±(2% m.v. + 5 digits)
  • frequency range: 50…400 Hz.

 

DC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(0,8% m.v. + 2 digits)
4,000 V 0,001 V ±(1,5% m.v. + 2 digits)
40,00 V 0,01 V ±(1,5% m.v. + 2 digits)
400,0 V 0,1 V ±(1,5% m.v. + 2 digits)
600,0 V 1 V ±(2% m.v. + 2 digits)

 

Resistance measurement

Range Resolution Accuracy
400,0 Ω 0,1 Ω ±(1,0% m.v. + 4 digits)
4,000 kΩ 0,001 kΩ ±(1,5% m.v. + 2 digits)
40,00 kΩ 0,01 kΩ ±(1,5% m.v. + 2 digits)
400,0 kΩ 0,1 kΩ ±(1,5% m.v. + 2 digits)
4,000 MΩ 0,001 MΩ ±(2,5% m.v. + 3 digits)
40,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 digits)

 

Capacitance measurement

Range Resolution Accuracy
40,00 nF 0,01 nF ±(4% m.v. + 20 digits)
400,0 nF 0,1 nF ±(3% m.v. + 5 digits)
4,000 nF 0,001 μF ±(3% m.v. + 5 digits)
40,00 nF 0,01 μF ±(3% m.v. + 5 digits)
100,0 nF 0,1 μF ±(4% m.v. + 10 digits)

„m.v.”- measured value

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-401 Digital Clamp-on multimeter”

There are no reviews yet.

  • YIHUA 937D Repairing Soldering Iron

    0 out of 5
    (0)

    Standard Configuration

    Main unit    1set

    Soldering iron handle (include iron tips and heater)    1pc

    Iron holder      1pc

    High temperature resistant sponge     1pc

    Manual 1pc

    Power plug :1pc

     

    Application Scope


    1. Production lines for electronic products ,.
      2. Repair industry for moblie phone.
      3. SMD components requiring the highest precision.

    SKU: n/a
  • UT39A+ Digital Multimeter

    0 out of 5
    (0)

    1. 1000V DC voltage measurement

    2. 750V AC voltage measurement
    3. 10A DC/AC current measurement
    4. Resistance/Capacitance
    5. hFE
    6. Diode/Continuity test
    SKU: n/a
  • UT601 Inductance Capacitance Meters

    0 out of 5
    (0)

    UT600 series RCL meter is a kind of 3.5-bithandheld digital meter with stable performance, safety, reliability, highaccuracy and manual range. It can be used to measure the magnification times β of audion, diode forward voltage drop and circuit continuity. UT601has wide capacitance measurement range from 0.1pF~20mF and highaccuracy. UT602 can hold data. UT 600 series is applicable to testingresistance, capacitance and inductance of electronic laboratory, productionline, maintenance point and teaching. It is the ideal tool of maintaining formany users

    SKU: n/a
  • MC TIP 900M TIS

    0 out of 5
    (0)
    SKU: n/a
  • UT315 Vibration Tester

    0 out of 5
    (0)

    Main Features

    1. Can measure acceleration, velocity and displacement

    2. Can select different vibration frequency

    3. High sensitivity sensor probe makes measurement accurate

    4. Auto power off

    5. Data hold

    6. LCD backlight

    7. Max mode

    8. Data storage: 1,999 groups of data

    9. USB interface

    10. Equipped with long and short probes for different field measurements

    11. Equipped with magnet pedestal for ergonomic purpose

    12.  Complies with CE (European Union) directives

    SKU: n/a