MRU-30 Earth Resistance and Resistivity Meter

Availability:

3 in stock


 

  • It allows to take the measurements of:

    • earthing resistance using auxiliary electrodes,
    • earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
    • earthing resistance using double clamps for measuring multiple earthing without underground connections.
    • ground resistivity (Wenner method),
    • continuity of equipotential bondings and protective
    • conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.

    Additionally:

    • measurement of resistance of auxiliary electrodes RS and RH,
    • measurement of interference voltage,
    • measurement in the presence of interference voltage in the power network
    • with frequency 50Hz, 60Hz,
    • selection of maximum measuring voltage (25V and 50V),
    • introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
    • memory of 990 measurements (10 banks of 99 cells each),
    • calibration of clamp used,
    • data transmission to the computer (USB),
    • indication of battery state.

0

3 in stock

Compare

The Sonel MRU-30 uses most known methods of earth resistance measurements. Tests can be performed using the 3-pole, 4-pole, 3-pole with auxiliary clamp and also, additionally, the MRU-30 employs the two clamp method of measurement, without the use of auxiliary test rods which can’t be used in some situations. Complementary features of the MRU-30 are measurements of soil resistivity, continuity measurement of protective and equipotential conductors and, using clamps, leakage currents and interference voltages.

  • Robust and weatherproof (IP65) – no ingress of dust, water protected by a nozzle against enclosure from any direction.
  • Ergonomic casing – small and handy casing to make the measurements more convenient than before.
  • Built-in rechargeable battery – saving time to replace flat batteries; can be recharged from Power Bank and Cigarette Lighter Socket!
  • Clear on-screen notes – displayed on screen before and after the measurement to alert user of possible dangers and irregularities.
  • Many measurement methods available in a small, portable casing
Weight 5 kg
Dimensions 20 × 15 × 7 cm

Measurement of interference voltage UN (RMS)

Range Resolution Accuracy
0…100 V 1 V ±(10% m.v. + 1 digit)

Measurement of continuity of equipotential bondings and protective conductors (Rcont)
measurement range to IEC 61557-4:2007: 0,13 Ω…1999 Ω

Range Resolution Accuracy
0,00…9,99 Ω 0,01 Ω ±(2% m.v. + 3 digits)
10,0…99,9 Ω 0,1 Ω
100…1999 Ω 1 Ω

• measurement current: under short circuit >200mA
• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz (for networks 60 Hz)

Measurement of earthing resistance (method 3- and 4-pole)
measurement range to IEC 61557-5:2007: 0,53 Ω…9999 Ω (dla 50 V)

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(3% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200,0…1999 Ω 1 Ω ±5% m.v.
2000…9999 Ω 1 Ω ±8% m.v.

• measurement current: under short circuit >20 mA,
• voltage on open terminals: selectable 25 V AC or 50 V AC,
• frequency of measurement current: 125 Hz (for networks 50 Hz) or 150 Hz (for 60 Hz).

Measurement of multiple earthing esistance with using the clamp and auxiliary electrodes (3p + clamp)

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(3% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200…1999 Ω 1 Ω ±5% m.v.
2000…9999 Ω 1 Ω ±8% m.v.

• voltage on open terminals: selectable 25 V AC or 50 V AC,
• measurement current: under short circuit >20 mA,
• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz (for networks 60 Hz)
Measurement of resistance of auxiliary electrodes RH i RS

Range Resolution Accuracy
0…999 Ω 1 Ω ±(5% m.v.+ 8 digits)
1,00k…9,99 kΩ 0,01 kΩ
10,0k…19,9 kΩ 0,1 kΩ

 

Measurement of multiple earthing resistance with using double clamps

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(10% m.v. + 8 digits)
20,0…99,9 Ω 0,1 Ω ±(20% m.v. + 3 digits)

• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz
(for networks 60 Hz)

Measurement of ground resistivity 
Measurement method: Wenner, ρ=2πLRE

Range Resolution Accuracy
0,00…9,99 Ωm 0,01 Ωm depending on measurement
accuracy RE with 4p method,
but not less than ±1 digit
10,0…99,9 Ωm 0,1 Ωm
100…999 Ωm 1 Ωm
1,00…9,99 kΩm 0,01 kΩm
10,0…99,9 kΩm 0,1 kΩm
100…999 kΩm 1 kΩm

L – distance between probes: 1…50 m.. or 1…150 ft

Electric security:

  • type of insulation: double, according to EN 61010-1 i IEC 61557,
  • measurement category: CAT III 300V wg EN 61010-1,
  • protection class acc. to EN 60529: IP65,

Rated operational conditions:

  • operation temperature: -10…+55°C,
  • storage temperature: -20…+80°C,
  • humidity: 20…90%,

Other technical data:

  • LCD display: segment, backlit,
  • dimensions: 200x150x74 mm.

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MRU-30 Earth Resistance and Resistivity Meter”

There are no reviews yet.

  • UT71E Intelligent Digital Multimeters

    0 out of 5
    (0)

    1. 40,000 counts, and basic DCV accuracy of 0.025%

    2. Can set the interval for auto data recording

    3. MAX/MIN/REL measurement mode

    4. Peak hold

    5. Analogue bar graph

    6. Measure AC and DC in the same stall (AC+DC)

    7. 4-20mA loop test

    8. 45Hz~100kHz frequency response measurement

    9. Double backlight

    10. Misplug alarm

    11. Auto and manual ranges selectable

    12. USB interface available

    13. Bluetooth connection with a cellphone for data monitoring

    14.Power measurement mode

    15. Temperature measurement mode, equipped with K-type point contact temperature probe

    16. Complies with CE (European Union) and UL (United States) directives

    SKU: n/a
  • Digital Clamp Meter UT202+ UNI-T

    0 out of 5
    (0)
    Specifications Range UT202+
    AC current (A) 400A ±(2%+10)
    600A
    AC current frequency (Hz) 50Hz~100Hz ±(1%+5)
    AC voltage (V) 600V ±(0.8%+5)
    AC voltage frequency(Hz) 10Hz~10kHz ±(1%+5)
    10Hz~60kHz
    Resistance (Ω) 40MΩ ±(0.8%+2)
    60MΩ
    Capacitance (F) 4mF ±(4%+5)
    40mF
    60mF
    Temperature (℃) -40℃~1000℃ ±(1.5%+5)
    Frequency (Hz) 10Hz~10MHz
    Features
    Display count 4000
    Auto range
    Jaw opening 28mm
    True RMS
    NCV
    Live wire test
    Continuity test
    Diode
    MAX/MIN
    Relative mode
    Zero mode
    Data hold
    Low battery indication
    Auto power off
    General Characterisitics
    Power 1.5V battery (R03) x 2
    Display 37mm x 25mm
    Product color Red and grey
    Product net weight 248g
    Product size 215mm x 63mm x 36mm
    Standard accessories Batteries, test leads, Themocouple
    Standard individual packing Gift box, Carring bag, English manual
    Standard quantity per carton 40pcs
    Standard carton measurement 485mm x 295mm x 385mm
    Standard carton gross weight 17.8kg
    SKU: n/a
  • SVC 2000VA

    0 out of 5
    (0)

    Input=120V 270
    Output=220
    Under and Over Volt Protection
    Surge Protection
    Over Load and Heat Protection
    Copper Wind with LCD Display

    SKU: n/a
  • UT395C Professional Laser Distance Meter

    0 out of 5
    (0)

    UT395 series are professional laser distance meters with color LCD display, electronic multi-axis leveler and other special features. Its unique operating system, friendly user interface, and personalized settings option all make these devices the perfect choice for professional distance measurement.

    SKU: UN39C5T
  • CMP-1006 Digital Clamp-on multimeter

    0 out of 5
    (0)

     

    Additionally:

    • safe, insulated measuring clamps,
    • autoranging/manual range selection,
    • DATA HOLD function, for holding measured values,
    • backlit LCD,
    • DC ZERO mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored zero value,
    • MAX/MIN function,
    • over range indication,
    • AUTO-OFF function.
    SKU: n/a