Fluke 15B+ Digital Multimeter

Availability:

Out of stock


Key features

  • 600 V Cat III safety rating
  • 50% bigger display with bright white backlight
  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A current
  • Diode test, data hold

21,058

Out of stock

Compare

Fluke quality is always within your reach

Your job requires that you have a rugged, reliable and accurate digital multimeter. The Fluke 15B+ digital multimeter does all that and more. Easy to use with one hand, even with gloves on, the Fluke 15B+ offers everything you need.

Category:

Specifications: Fluke 15B+ Digital Multimeter

Accuracy Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).

Function Range Resolution Accuracy
AC volts
(40 Hz to 500Hz)1
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0% + 3
DC volts 4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5% + 3
AC millivolts 400.0 mV 0.1 mV 3.0% + 3
DC millivolts 400.0 mV 0.1 mV 1.0% + 10
Diode test2 2.000 V 0.001 V 10%
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5% + 3
0.5% + 2
0.5% + 2
0.5% + 2
0.5% + 2
1.5% + 3
Capacitance3 40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
AC current μA
(40 Hz to 400 Hz)
400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
AC current mA
(40 Hz to 400 Hz)
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
AC current A
(40 Hz to 400 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
DC current μA 400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
DC current mA 40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
DC current A 4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
Backlight Yes
1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
Function Overload protection Input impedance (Nominal) Common mode rejection ratio Normal mode rejection ratio
AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc,
50 Hz or 60 Hz
AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
1 106 V Hz Max
General specifications
Maximum voltage between any terminal and earth ground 1000 V
Display (LCD) 4000 counts, updates 3/sec
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C
Relative humidity
Operating humidity Non-condensing (<10°C)
≤90% RH at 10 °C to 30 °C;
≤75% RH at 30 °C to 40 °C
40 MΩ range
≤80% RH at 10 °C to 30 °C;
≤70% RH at 30 °C to 40 °C
Altitude
Operating 2000 m
Storage 12,000 m
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs 440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only.
Size (H x W x L) 183 x 91 x 49.5 mm
Weight 455 g
IP rating IP 40
Safety IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
Electromagnetic environment IEC 61326-1: Portable
Electromagnetic compatibility Applies to use in Korea only
Class A equipment (industrial broadcasting & communication equipment)1
1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or
user should take notice of it. This equipment is intended for use in business environments and is not to be
used in homes.

Brand

FLUKE

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Fluke 15B+ Digital Multimeter”

There are no reviews yet.

  • UT216B 600A True RMS Digital Clamp Meters

    0 out of 5
    (0)

    UT216 series true RMS digital clamp meter is a new-generation practical electrotechnical measurement meter which has the features of high reliability, high safety, automatic range and handheld type, has full-range overload protection and unique appearance design, is more excellent in performance, and is an ideal tool for detection, maintenance and repair of various universities and colleges, smelting, communication, manufacturing, petroleum, national defense, electrical, power and circuit equipment.
    UTD216B (main features)

    • 1、600A AC current measurement;
    • 2、True RMS response for ACV and ACA;
    • 3、99.99mF capacitance measurement;
    • 4、V.F.C function for measuring signal at variable frequency ;
    • 5、Non-contact voltage detection with LED indication;
    • 6、Flashlight for working at dark environment.
    SKU: n/a
  • UT262A Non-Contact Phase Detector

    0 out of 5
    (0)

    UT262 series adopts clamp type non-contact measuring method, which means user doesn’t need to get in touch with high-voltage exposed wires. It can start detection after three super-induction and high-insulation clamps clamp the exterior of the three-phase wires, which is safer, more practical, and more effective. Beside phase sequence detection, UT262 series can be also used for live wire detection, simple electrical inspection, phase identification, missing-phase judgment, and wire breaker searching. It is a perfect tool for phase sequence detection, motor mounting, and wires maintenance.

    SKU: 22000
  • LM1500 Laser Rangefinders

    0 out of 5
    (0)

    Features of LM Series Laser Rangefinders

    Certificates: CE, RoHS

    ● 7X optical zoom telescope
    ● HD coating
    ● Skidproof
    ● Built-in Li-ion battery

    ● Distance: 5~1500yd
    ● Height: 0~600yd
    ● Speed: 0~300km/h (0~186mi/h)
    ● Angle: ±45℃

    SKU: n/a
  • TDR-420 Time Domain Reflectometer/ Cable Fault Locator

    0 out of 5
    (0)

    Product features

    • Possibility damage-free location of impedance changes of tested cables and wires such as:
      • shorted conductor,
      • open conductor / end of cable – useful during the inventory of warehouses and stores,
      • splice,
      • splitter,
      • water ingress,
      • wet splice,
      • bridge tap
      • or other changes.
    • Single measurement mode ONCE,
    • Continuously measurement mode CONT,
    • Tone signal generator TONE,
    • Two cursors to mark two places of damage along with an indication of the distance between them,
    • Built-in HELP function for easier interpretation of the reflectogram,
    • 11 available measuring ranges from 7 m to 6000 m,
    • „dead zone” limited to 0.6 m,
    • Color 3,5” LCD TFT display with resolution 320 x 240 pixels,
    • manually set of sensitivity in 8 steps GAIN,
    • output impedance regulation up to 200 Ω (possibility of measuring pre-insulated pipes),
    • Velocity of Propagation set in range from 10% to 99%,
    • tight and durable housing with IP67 ingress protection degree.
    • Small size and weight.
    SKU: n/a