  • It allows to take the measurements of:

    • earthing resistance using auxiliary electrodes,
    • earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
    • earthing resistance using double clamps for measuring multiple earthing without underground connections.
    • ground resistivity (Wenner method),
    • continuity of equipotential bondings and protective
    • conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.

    Additionally:

    • measurement of resistance of auxiliary electrodes RS and RH,
    • measurement of interference voltage,
    • measurement in the presence of interference voltage in the power network
    • with frequency 50Hz, 60Hz,
    • selection of maximum measuring voltage (25V and 50V),
    • introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
    • memory of 990 measurements (10 banks of 99 cells each),
    • calibration of clamp used,
    • data transmission to the computer (USB),
    • indication of battery state.

0

3 in stock

Compare

The Sonel MRU-30 uses most known methods of earth resistance measurements. Tests can be performed using the 3-pole, 4-pole, 3-pole with auxiliary clamp and also, additionally, the MRU-30 employs the two clamp method of measurement, without the use of auxiliary test rods which can’t be used in some situations. Complementary features of the MRU-30 are measurements of soil resistivity, continuity measurement of protective and equipotential conductors and, using clamps, leakage currents and interference voltages.

  • Robust and weatherproof (IP65) – no ingress of dust, water protected by a nozzle against enclosure from any direction.
  • Ergonomic casing – small and handy casing to make the measurements more convenient than before.
  • Built-in rechargeable battery – saving time to replace flat batteries; can be recharged from Power Bank and Cigarette Lighter Socket!
  • Clear on-screen notes – displayed on screen before and after the measurement to alert user of possible dangers and irregularities.
  • Many measurement methods available in a small, portable casing
Weight 5 kg
Dimensions 20 × 15 × 7 cm

Measurement of interference voltage UN (RMS)

Range Resolution Accuracy
0…100 V 1 V ±(10% m.v. + 1 digit)

Measurement of continuity of equipotential bondings and protective conductors (Rcont)
measurement range to IEC 61557-4:2007: 0,13 Ω…1999 Ω

Range Resolution Accuracy
0,00…9,99 Ω 0,01 Ω ±(2% m.v. + 3 digits)
10,0…99,9 Ω 0,1 Ω
100…1999 Ω 1 Ω

• measurement current: under short circuit >200mA
• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz (for networks 60 Hz)

Measurement of earthing resistance (method 3- and 4-pole)
measurement range to IEC 61557-5:2007: 0,53 Ω…9999 Ω (dla 50 V)

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(3% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200,0…1999 Ω 1 Ω ±5% m.v.
2000…9999 Ω 1 Ω ±8% m.v.

• measurement current: under short circuit >20 mA,
• voltage on open terminals: selectable 25 V AC or 50 V AC,
• frequency of measurement current: 125 Hz (for networks 50 Hz) or 150 Hz (for 60 Hz).

Measurement of multiple earthing esistance with using the clamp and auxiliary electrodes (3p + clamp)

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(3% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200…1999 Ω 1 Ω ±5% m.v.
2000…9999 Ω 1 Ω ±8% m.v.

• voltage on open terminals: selectable 25 V AC or 50 V AC,
• measurement current: under short circuit >20 mA,
• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz (for networks 60 Hz)
Measurement of resistance of auxiliary electrodes RH i RS

Range Resolution Accuracy
0…999 Ω 1 Ω ±(5% m.v.+ 8 digits)
1,00k…9,99 kΩ 0,01 kΩ
10,0k…19,9 kΩ 0,1 kΩ

 

Measurement of multiple earthing resistance with using double clamps

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(10% m.v. + 8 digits)
20,0…99,9 Ω 0,1 Ω ±(20% m.v. + 3 digits)

• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz
(for networks 60 Hz)

Measurement of ground resistivity 
Measurement method: Wenner, ρ=2πLRE

Range Resolution Accuracy
0,00…9,99 Ωm 0,01 Ωm depending on measurement
accuracy RE with 4p method,
but not less than ±1 digit
10,0…99,9 Ωm 0,1 Ωm
100…999 Ωm 1 Ωm
1,00…9,99 kΩm 0,01 kΩm
10,0…99,9 kΩm 0,1 kΩm
100…999 kΩm 1 kΩm

L – distance between probes: 1…50 m.. or 1…150 ft

Electric security:

  • type of insulation: double, according to EN 61010-1 i IEC 61557,
  • measurement category: CAT III 300V wg EN 61010-1,
  • protection class acc. to EN 60529: IP65,

Rated operational conditions:

  • operation temperature: -10…+55°C,
  • storage temperature: -20…+80°C,
  • humidity: 20…90%,

Other technical data:

  • LCD display: segment, backlit,
  • dimensions: 200x150x74 mm.

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MRU-30 Earth Resistance and Resistivity Meter”

There are no reviews yet.

  • UT395A Professional Laser Distance Meter

    0 out of 5
    (0)

    UT395 series are professional laser distance meters with color LCD display, electronic multi-axis leveler and other special features. Its unique operating system, friendly user interface, and personalized settings option all make these devices the perfect choice for professional distance measurement.

    SKU: n/a
  • UT207A Digital Clamp Meters (Discontinued)

    0 out of 5
    (0)

    Features of UT207/A to UT209/A Series 1000A Digital Clamp Meters

    Certificates: CE, RoHS

    ● 1000A AC/DC current measurement, 3 times/s sampling rate
    ● Auto/manual ranges selectable (UT207A/UT208A/UT209A)
    ● True RMS (UT207/UT208/UT209/UT209A)
    ● Analog bar graph (UT209)
    ● Inrush current (UT207/UT208)
    ● Zeroing function
    ● Full icon display (UT207/UT208/UT209)
    ● MAX/MIN (UT207/UT208/UT209)
    ● LCD backlight (UT207A/UT208A/UT209A)
    ● Data hold; Duty cycle (except UT209 )
    ● Auto power off and low battery indication
    ● Point contact temperature probe (UT208/UT208A)
    ● Diode; Continuity buzzer; Input Impedance for DCV

    SKU: n/a
  • VICTOR 3010 Digital Pocket Analog Multimeter 10A 1000V With Resistance Function

    0 out of 5
    (0)

    VICTOR 3010 Digital Pocket Analog Multimeter 10A 1000V With Resistance Function

    SKU: n/a
  • UT612 LCR Meters

    0 out of 5
    (0)

    UT610 series is a handheld LCR digitalelectric bridge meter with stable performance, safety, reliability and autorange. It is professional to measure inductance, capacitance and resistance. Ithas the features of low power dissipation, high accuracy and fast speed. It canselect the series-parallel measurement mode; measure the quality factor ofcomponents, the loss, the phase angle, equivalent resistance and DC resistance.It can provide up to 5 kinds of frequency under the inductance, capacitance andresistance mode to satisfy the actual requirement.

     

    It is applicable to measuring and filtratingthe inductance, capacitance and resistance of lab, production line, maintenancepoint and teaching. It is the ideal tool of maintaining for many users.

    SKU: n/a
  • LM100G Laser Distance Meters (Discontinued)

    0 out of 5
    (0)

    Features of LM50G/LM70G/LNM100G Laser Distance Meters

    ● LD green laser

    SKU: n/a
  • UT256B ACA DCA Fork Clamp Meters

    0 out of 5
    (0)

    UT256 series is an AC/DC fork meter with high reliability, high security, auto-range, and mini shape. Its appearance adopts creative design so that wires to be tested can be stuck by the jaw directly instead of after the jaw is pressed to open. It can measure AC/DC current provided with true RMS function. Flashlight on the meter is specially designed for smooth measurement under darkness. Full-range overload protection and distinctive appearance design make it be a new-generation practical electrical measuring meter with better performance.

    SKU: n/a