  • It allows to take the measurements of:

    • earthing resistance using auxiliary electrodes,
    • earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
    • earthing resistance using double clamps for measuring multiple earthing without underground connections.
    • ground resistivity (Wenner method),
    • continuity of equipotential bondings and protective
    • conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.

    Additionally:

    • measurement of resistance of auxiliary electrodes RS and RH,
    • measurement of interference voltage,
    • measurement in the presence of interference voltage in the power network
    • with frequency 50Hz, 60Hz,
    • selection of maximum measuring voltage (25V and 50V),
    • introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
    • memory of 990 measurements (10 banks of 99 cells each),
    • calibration of clamp used,
    • data transmission to the computer (USB),
    • indication of battery state.

0

3 in stock

Compare

The Sonel MRU-30 uses most known methods of earth resistance measurements. Tests can be performed using the 3-pole, 4-pole, 3-pole with auxiliary clamp and also, additionally, the MRU-30 employs the two clamp method of measurement, without the use of auxiliary test rods which can’t be used in some situations. Complementary features of the MRU-30 are measurements of soil resistivity, continuity measurement of protective and equipotential conductors and, using clamps, leakage currents and interference voltages.

  • Robust and weatherproof (IP65) – no ingress of dust, water protected by a nozzle against enclosure from any direction.
  • Ergonomic casing – small and handy casing to make the measurements more convenient than before.
  • Built-in rechargeable battery – saving time to replace flat batteries; can be recharged from Power Bank and Cigarette Lighter Socket!
  • Clear on-screen notes – displayed on screen before and after the measurement to alert user of possible dangers and irregularities.
  • Many measurement methods available in a small, portable casing
Weight 5 kg
Dimensions 20 × 15 × 7 cm

Measurement of interference voltage UN (RMS)

Range Resolution Accuracy
0…100 V 1 V ±(10% m.v. + 1 digit)

Measurement of continuity of equipotential bondings and protective conductors (Rcont)
measurement range to IEC 61557-4:2007: 0,13 Ω…1999 Ω

Range Resolution Accuracy
0,00…9,99 Ω 0,01 Ω ±(2% m.v. + 3 digits)
10,0…99,9 Ω 0,1 Ω
100…1999 Ω 1 Ω

• measurement current: under short circuit >200mA
• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz (for networks 60 Hz)

Measurement of earthing resistance (method 3- and 4-pole)
measurement range to IEC 61557-5:2007: 0,53 Ω…9999 Ω (dla 50 V)

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(3% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200,0…1999 Ω 1 Ω ±5% m.v.
2000…9999 Ω 1 Ω ±8% m.v.

• measurement current: under short circuit >20 mA,
• voltage on open terminals: selectable 25 V AC or 50 V AC,
• frequency of measurement current: 125 Hz (for networks 50 Hz) or 150 Hz (for 60 Hz).

Measurement of multiple earthing esistance with using the clamp and auxiliary electrodes (3p + clamp)

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(3% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200…1999 Ω 1 Ω ±5% m.v.
2000…9999 Ω 1 Ω ±8% m.v.

• voltage on open terminals: selectable 25 V AC or 50 V AC,
• measurement current: under short circuit >20 mA,
• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz (for networks 60 Hz)
Measurement of resistance of auxiliary electrodes RH i RS

Range Resolution Accuracy
0…999 Ω 1 Ω ±(5% m.v.+ 8 digits)
1,00k…9,99 kΩ 0,01 kΩ
10,0k…19,9 kΩ 0,1 kΩ

 

Measurement of multiple earthing resistance with using double clamps

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(10% m.v. + 8 digits)
20,0…99,9 Ω 0,1 Ω ±(20% m.v. + 3 digits)

• frequency of measurement current: 125 Hz (for networks 50 Hz) and 150 Hz
(for networks 60 Hz)

Measurement of ground resistivity 
Measurement method: Wenner, ρ=2πLRE

Range Resolution Accuracy
0,00…9,99 Ωm 0,01 Ωm depending on measurement
accuracy RE with 4p method,
but not less than ±1 digit
10,0…99,9 Ωm 0,1 Ωm
100…999 Ωm 1 Ωm
1,00…9,99 kΩm 0,01 kΩm
10,0…99,9 kΩm 0,1 kΩm
100…999 kΩm 1 kΩm

L – distance between probes: 1…50 m.. or 1…150 ft

Electric security:

  • type of insulation: double, according to EN 61010-1 i IEC 61557,
  • measurement category: CAT III 300V wg EN 61010-1,
  • protection class acc. to EN 60529: IP65,

Rated operational conditions:

  • operation temperature: -10…+55°C,
  • storage temperature: -20…+80°C,
  • humidity: 20…90%,

Other technical data:

  • LCD display: segment, backlit,
  • dimensions: 200x150x74 mm.

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MRU-30 Earth Resistance and Resistivity Meter”

There are no reviews yet.

  • LM150 Laser Distance Meter

    0 out of 5
    (0)

    1. Ergonomic exterior, comfortable handling

    2. Millimeter accuracy
    3. Large, multiple angle HD display
    5. Physical and electronics leveler
    6. Multiple functions: Max/Min/continuous measurement, displacement calculation, data storage, and more
    7. Auto power off after 3 minutes without operation
    SKU: n/a
  • ET 8102 DMM

    0 out of 5
    (0)

    Specifications:
    Model:ET8102
    Display:5999 Counts
    Color:Black
    DC Voltage:6V/60V/600V±(0.5%+3),1000V±(0.8%+10)
    AC Voltage:6V/60V/600V±(0.8%+3),750V±(1.2%+10)
    DC Current:600uA/6000uA/60mA/600mA±(1.2%+10),6A/10A±(2.0%+30)
    AC Current:600uA/6000uA/60mA/600mA±(1.2%+10),6A/10A±(2.0%+30)
    Resistance:600Ω±(0.8%+5),6KΩ/60KΩ/600KΩ/6MΩ±(0.8%+3),40MΩ±(2.5%+3)
    Capacitance:60nF/600nF/6μF/60μF/600μF±(3.5%+20),6mF/30mF±(5.0%+3)
    Frequency:10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz±(0.1%+3)
    Temperature:-20℃~1000℃,±(1.0%+5)<400℃,±(1.5%+15)≥400℃
    0℉~1832℉,±(0.75%+5)<750℉,±(1.5%+15)≥750℃
    NCV test:Yes
    Zero line/fire wire:Yes
    Duty cycle:Yes
    Diode test:Yes
    Continuity testing:Yes
    Backlight:Yes
    Date hold:Yes
    True RMS:Yes
    Max/Min value measurement:Yes
    Flashlight:Yes
    Auto power off:Yes
    Low battery indication:Yes
    Over range indication:Yes
    Power:2 x 1.5V AAA Battery (not included)
    Product Size:142 x 68 x 32 mm
    Product Net Weight:187g

    Package Information:
    Package Size:16.5 x 10 x 5cm / 6.5 x 3.9 x 2in
    Package Weight:295g / 10.4 oz

    Package list:
    1 x Digital Multimeter
    2 x Test Leads Pens
    1 x User Manual
    • 1.Multifunction:Can measure AC/DC voltage,AC/DC current,resistance,capacitance,
    • 2.Portable design:Small and can be put into pocket,easy to carry.
    • 3.Wide range of applications:It’s a perfect tool for the laboratory,factory and home.
    • 4.Easy to use & clear to read:With large LCD backlight display and flashlight function,convenient to read data in dark.
    • frequency,duty cycle,temperature,NCV,diode,continuity,zero line/fire wire.

    SKU: n/a
  • JM OP013

    0 out of 5
    (0)
    SKU: n/a
  • PHASE INDICATOR KEW 8031

    0 out of 5
    (0)

    ・Two Functions in One Unit
    Presence of open phase can be checked by the lamps, and the phase
    sequence can be indicated by the rotating disk.

    ・ High Reliability
    measuring range for 3-phase installations from 110V to 600V.
    Sealed against dust ensures the trouble-free performance.

    ・ Battery-free tester

    SKU: n/a
  • LM 100A Laser Distance Meters

    0 out of 5
    (0)

    Features of LM A Series Laser Distance Meters

    Certificates: CE, UKCA

    ● Ergonomic exterior, comfortable handling
    ● Millimeter accuracy
    ● 99 groups data storage
    ● Quick, self calculation with real-time readout
    ● Physical leveler(Horizontal and vertical)
    ● Multiple functions: Max/Min/continuous measurement, data storage, etc

    SKU: n/a
  • UT60BT

    0 out of 5
    (0)

    Features of UT60 Series Digital Multimeters

    Certificates: CE, UKCA, cETLus

    ● 9999 counts
    ● True RMS
    ● Bluetooth
    ● Duty cycle
    ● Diode/Continuity test
    ● Temperature

    ● Non-contact voltage
    ● Analog bar/Data hold
    ● Backlight/Relative mode
    ● Auto/Manual range
    ● Low battery indication
    ● Three-color LED light indicator

    Video for UT60EU:

    Video for UT60S:

    SKU: n/a