-18%

CMM-10 Multimeter

Availability:

5 in stock


  • Autoranging/manual range selection.
  • DATA HOLD function, for holding measured values.
  • REL function, which allows you to make measurements relative to a stored reference value.
  • Continuity test with acoustic signalling (beeper).
  • AUTO-OFF function.
  • Display 3 7/8 digits (5000 max).

11,844 14,478

5 in stock

Compare

The most important features of CMM-10 are:

  • Autoranging/manual range selection.
  • DATA HOLD function, for holding measured values.
  • REL function, which allows you to make measurements relative to a stored reference value.
  • Continuity test with acoustic signalling (beeper).
  • AUTO-OFF function.
  • Display 3 7/8 digits (5000 max).
Category:
Weight 0.2 kg
Dimensions 14 × 7 × 4 cm

Frequency measurement

Range Resolution Accuracy
5,000 Hz 0,001 Hz ±(1,5% m.v. + 5 digits)
50,00 Hz 0,01 Hz
500,0 Hz 0,1 Hz ±(1,2% m.v. + 3 digits)
5,000 kHz 0,001 kHz
50,00 kHz 0,01 kHz
500,0 kHz 0,1 kHz
5,000 MHz 0,001 MHz ±(1,5% m.v. + 4 digits)
10,00 MHz 0,01 MHz
  • sensitivity: ≥8 V RMS

Duty cycle measurement

Range Resolution Accuracy
0,1…99,9% 0,1% ±(1,2% m.v. + 2 digits)
  • sensitivity: ≥8 V RMS,
  • pulse width: 100µs – 100 ms,
  • frequency width: 5 Hz…150 kHz.

Temperature measurement

Range Resolution Accuracy*
-20°C…+760°C 1°C ±(3% m.v. + 5°C, 9°F)
-4°F…+1400°F 1°F

*) probe (K type) accuracy not included

DC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(0,5% m.v. + 2 digits)
4,000 V 0,001 V ±(1,2% m.v. + 2 digits)
40,00 V 0,01 V ±(1,2% m.v. + 2 digits)
400,0 V 0,1 V
600 V 1 V ±(1,5% m.v. + 2 digits)
  • input impedance: 7,8 MΩ

AC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(1,5% m.v. + 70 digits)
4,000 V 0,001 V ±(1,2% m.v. + 3 digits)
40,00 V 0,01 V ±(1,5% m.v. + 3 digits)
400,0 V 0,1 V
600 V 1 V ±(2,0% m.v. + 4 digits)
  • input impedance: 7,8 MΩ,
  • frequency range: 50…400 Hz.

DC current measurement

Range Resolution Accuracy
400,0 μA 0,1 μA ±(1,0% m.v. + 3 digits)
4 000 μA 1 μA ±(1,5% m.v. + 3 digits)
40,00 mA 0,01 mA
400,0 mA 0,1 mA
4,000 A 0,001 A ±(2,5% m.v. + 5 digits)
10,00 A 0,01 A

AC current measurement

Range Resolution Accuracy
400,0 μA 0,1 μA ±(1,5% m.v. + 5 digits)
4 000 μA 1 μA ±(1,8% m.v. + 5 digits)
40,00 mA 0,01 mA
400,0 mA 0,1 mA
4,000 A 0,001 A ±(3,0% m.v. + 7 digitgs)
10,00 A 0,01 A
  • frequency range: 50…400 Hz.

Resistance measurement

Range Resolution Accuracy
400,0 Ω 0,1 Ω ±(1,2% m.v. + 4 digits)
4,000 kΩ 0,001 kΩ ±(1,0% m.v. + 2 digits)
40,00 kΩ 0,01 kΩ ±(1,2% m.v. + 2 digits)
400,0 kΩ 0,1 kΩ
4,000 MΩ 0,001 MΩ
40,00 MΩ 0,01 MΩ ±(2,0% m.v. + 3 digits)

Capacitance measurement

Range Resolution Accuracy
40,00 nF 0,01 nF ±(5,0% m.v. + 7 digits)
400,0 nF 0,1 nF ±(3,0% m.v. + 5 digits)
4,000 μF 0,001 μF
40,00 μF 0,01 μF
100,0 μF 0,1 μF ±(5,0% m.v. + 5 digits)

“m.v” = measured value

Electric security:

  • type of insulation: double, according to EN 61010 – 1 and IEC 61557
  • measurement category: CAT II 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

Other technical data:

  • power supply: 9 V battery type 6LR61
  • diode test: I=0,3 mA, U0 = 1,5 V DC
  • continuity test: I<0,3 mA, sound signal for R<50 Ω
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • input impedance: 7,8 MΩ (V AC/DC)
  • display: 5000 counts LCD display with function indication
  • dimensions: 138 x 68 x 37 mm
  • weight: approx. 210 g
  • fuses: mA, µA range: 0,5 A/250 V fast; A range: 10 A/250 V fast
  • auto power OFF: 30 min.
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032

Rated operational conditions:

  • operating temperature: 0…+50°C at <70% rel. humidity
  • storage temperature: -20…+60°C at <80% rel. humidity

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMM-10 Multimeter”

There are no reviews yet.

  • YH 134B 110 ELEMENT

    0 out of 5
    (0)
    SKU: n/a
  • TDR-420 Time Domain Reflectometer/ Cable Fault Locator

    0 out of 5
    (0)

    Product features

    • Possibility damage-free location of impedance changes of tested cables and wires such as:
      • shorted conductor,
      • open conductor / end of cable – useful during the inventory of warehouses and stores,
      • splice,
      • splitter,
      • water ingress,
      • wet splice,
      • bridge tap
      • or other changes.
    • Single measurement mode ONCE,
    • Continuously measurement mode CONT,
    • Tone signal generator TONE,
    • Two cursors to mark two places of damage along with an indication of the distance between them,
    • Built-in HELP function for easier interpretation of the reflectogram,
    • 11 available measuring ranges from 7 m to 6000 m,
    • „dead zone” limited to 0.6 m,
    • Color 3,5” LCD TFT display with resolution 320 x 240 pixels,
    • manually set of sensitivity in 8 steps GAIN,
    • output impedance regulation up to 200 Ω (possibility of measuring pre-insulated pipes),
    • Velocity of Propagation set in range from 10% to 99%,
    • tight and durable housing with IP67 ingress protection degree.
    • Small size and weight.
    SKU: n/a
  • UT120A Pocket Size Type Digital Multimeters

    0 out of 5
    (0)

    Main Features

    1. Auto range

    2. Auto polarity indication

    3. Relative mode

    4. Data hold

    5. Auto power off Function

    6. Capacitance measurement

    7. Complies with CE (European Union) directives

    SKU: n/a