Fluke 15B+ Digital Multimeter

Availability:

Out of stock


Key features

  • 600 V Cat III safety rating
  • 50% bigger display with bright white backlight
  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A current
  • Diode test, data hold

21,058

Out of stock

Compare

Fluke quality is always within your reach

Your job requires that you have a rugged, reliable and accurate digital multimeter. The Fluke 15B+ digital multimeter does all that and more. Easy to use with one hand, even with gloves on, the Fluke 15B+ offers everything you need.

Category:

Specifications: Fluke 15B+ Digital Multimeter

Accuracy Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).

Function Range Resolution Accuracy
AC volts
(40 Hz to 500Hz)1
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0% + 3
DC volts 4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5% + 3
AC millivolts 400.0 mV 0.1 mV 3.0% + 3
DC millivolts 400.0 mV 0.1 mV 1.0% + 10
Diode test2 2.000 V 0.001 V 10%
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5% + 3
0.5% + 2
0.5% + 2
0.5% + 2
0.5% + 2
1.5% + 3
Capacitance3 40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
AC current μA
(40 Hz to 400 Hz)
400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
AC current mA
(40 Hz to 400 Hz)
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
AC current A
(40 Hz to 400 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
DC current μA 400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
DC current mA 40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
DC current A 4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
Backlight Yes
1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
Function Overload protection Input impedance (Nominal) Common mode rejection ratio Normal mode rejection ratio
AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc,
50 Hz or 60 Hz
AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
1 106 V Hz Max
General specifications
Maximum voltage between any terminal and earth ground 1000 V
Display (LCD) 4000 counts, updates 3/sec
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C
Relative humidity
Operating humidity Non-condensing (<10°C)
≤90% RH at 10 °C to 30 °C;
≤75% RH at 30 °C to 40 °C
40 MΩ range
≤80% RH at 10 °C to 30 °C;
≤70% RH at 30 °C to 40 °C
Altitude
Operating 2000 m
Storage 12,000 m
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs 440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only.
Size (H x W x L) 183 x 91 x 49.5 mm
Weight 455 g
IP rating IP 40
Safety IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
Electromagnetic environment IEC 61326-1: Portable
Electromagnetic compatibility Applies to use in Korea only
Class A equipment (industrial broadcasting & communication equipment)1
1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or
user should take notice of it. This equipment is intended for use in business environments and is not to be
used in homes.

Brand

FLUKE

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Fluke 15B+ Digital Multimeter”

There are no reviews yet.

  • CLAMP METER AC CM 2007

    0 out of 5
    (0)

    Specification of the item

    SKU: n/a
  • TND 3000VA

    0 out of 5
    (0)

    Input Voltage=140-250
    Output Voltage=220
    Copper Wind
    Analog Display
    Under and Over Volt Indication
    Under Volt Protection
    Dual Output Socket 110/220

    SKU: n/a
  • CLAMP METER AC DC CM 2016

    0 out of 5
    (0)
    Overview
    Essential details
    Place of Origin:
    Guangdong, China
    Brand Name:
    vici
    Model Number:
    CM-2016
    Display Type:
    Digital Only
    Measuring Current Range:
    60A/600A/800A
    Measuring Voltage Range:
    600mV/6V/60V/600V
    Measuring Resistance Range:
    600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ
    Measuring Capacitance Range:
    6nF/60nF/600nF/6uF/60uF/600uF/6mF/60mF
    Measuring Inductance Range:
    /
    Operating Temperature:
    23±5℃
    Dimensions:
    185*65*32mm
    Weight:
    200g(including the batteries)
    Backlight display/Clamp light dispaly:
    YES
    NCV:
    YES
    Diode test:
    YES
    clamp open:
    28mm
    power supply:
    2pcs 1.5V batteries
    Sampling rate:
    3 times/second
    AC frequency response:
    Current 50-60Hz/ voltage 50-400Hz
    Operation method:
    Auto range
    OEM service:
    Available
    Product Name:
    Vicimeter CM-2016 AC/DC 3 5/6 Digital Clamp Meter
    SKU: n/a
  • UT207A Digital Clamp Meters (Discontinued)

    0 out of 5
    (0)

    Features of UT207/A to UT209/A Series 1000A Digital Clamp Meters

    Certificates: CE, RoHS

    ● 1000A AC/DC current measurement, 3 times/s sampling rate
    ● Auto/manual ranges selectable (UT207A/UT208A/UT209A)
    ● True RMS (UT207/UT208/UT209/UT209A)
    ● Analog bar graph (UT209)
    ● Inrush current (UT207/UT208)
    ● Zeroing function
    ● Full icon display (UT207/UT208/UT209)
    ● MAX/MIN (UT207/UT208/UT209)
    ● LCD backlight (UT207A/UT208A/UT209A)
    ● Data hold; Duty cycle (except UT209 )
    ● Auto power off and low battery indication
    ● Point contact temperature probe (UT208/UT208A)
    ● Diode; Continuity buzzer; Input Impedance for DCV

    SKU: n/a
  • CLAMP METER AC CM 2030

    0 out of 5
    (0)

    Features

    . Digital clamp meter 266 opens 52mm.

    2. Large LCD display makes reading clear.

    3. Full function protection, strong anti-interferential performance.

    4. CE standard design, improves the safety of the test.

    5. Data hold.

    6. Clamp light and backlight display.

    SKU: n/a
  • UNI-T UTi320E High IR Resolution 320×240 Professional Handheld Thermal Imager with PC,WiFi and App Connect Support Data Analysis and Real Time Display

    0 out of 5
    (0)
    Screen Display 3.5″IPS
    Temeperature Range  -40°~400°
    IR Resolution(Pixels) 320×240
    Visible Camera Resolution 2MP
    Field of View(FOV) 56°x 42°
    Spatial Resolution(IFOV) 3mrad
    Frame Rate 9Hz
    Thermal Sensitivity(NETD) 65mK
    Measurement Accuracy ±2° or ±2%
    whichever is greater
    Emissivity 0.01-0.99 Adjustable
    Spectral Range 8~14μm
    Foucs Foucs Free
    Digital Zoom 2x, 4x
    Palattes 7(Iron, Rainbow, White Hot, Red Hot, Black Hot, Lava, Rainbow HC)
    Display Modes Thermal,Visible,Fusion,PIP
    Mesurement  Mode Center Pot,High/Low Temp Pot,ROI
    Temperature Analysis (Point 5 /Line 1 /Area 6 ) total 6 tools
    Battery Li-ion battery pack 5200mAh
    Battery Type Replaceable
    Battery Life  ≥ 4hours
    Charging Time ≤5Hours
    Communication interface Type-C
    IP Rating IP54
    Drop Proof 2m
    Functions
    Flashlight
    Tripod Hole
    Auto tracking of High/Low Temperature
    Auto Alarm of High/Low Temperature
    Image Capture
    Video Recording ×
    Voice Recording ×
    RIO(Eliminates Interference)
    Isotherm
    PC Real Time Image Transmisstion
    PC Analysis Software
    Wifi Photo Download
    Wifi Real Time Display ×
    Bluetooth ×
    Mobile APP
    GPS ×
    Laser/Distance Measurement ×
    SKU: n/a