1. 20:1 D:S ratio
Infrared Thermometer
UT 302A+ Infrared thermometer
Availability:
10 in stock
Specifications | UT302A+ |
Temperature range | -32℃~700℃ |
-25.6℉~1292℉ | |
Accuracy | ≥0℃: ±1.5℃ or ±1.5%; <0℃: ±(1.5℃+0.1℃/℃) |
≥32℉: ±3.0℉ or ±1.5%; <32℉: ±(3.0℉+0.1℉/℉) | |
Repeatability | 0.7℃ or 0.7% (1.5℉ or 0.7%) |
D:S ratio | 20:1 |
Response time | 250ms |
Emissivity | 0.1~1.0 (adjustable, stores 5 sets of preset values) |
Spectral response | 8um~14um |
Laser power | < 1mW |
Features | |
Auto power off | √ |
Low battery indication | √ |
LCD display | Color EBTN |
High/low LED alarm | √ |
High/low audible alarm | √ |
Data hold/Lock measurement | √ |
℃/℉ selection | √ |
MAX/MIN/AVG/DIFF mode | √ |
Data storage with date and time | – |
Scheduled measurement | – |
Backlight | √ |
Operating temperature | 0℃~50℃ (32℉~122℉) |
Storage temperature | -20℃~60℃ (-4℉~140℉) |
Operating humidity | <90%RH (non-condensing) |
Drop test | 1m |
Tripod mounting hole | √ |
General Characterisitics | |
Power | 9V battery |
Display | 35mm x 35mm |
Product color | Red and grey |
Product net weight | 310g |
Product size | 172mm x 113.5mm x 53mm |
Standard accessories | Battery, carrying bag |
Standard individual packing | Gift box, blister, English manual |
Standard quantity per carton | 10pcs |
Standard carton measurement | 425mm x 335mm x 365mm |
Standard carton gross weight | 6.65kg |
₨15,000 ₨18,381
10 in stock
Compare2. Adjustable emissivity 0.1~1.0
3. ±1.5℃ temperature measurement accuracy
4. User defined visual and audio alarm
5. High contrast EBTN color display
6. MAX/MIN/AVG/DIFF/Hold modes
Weight | 0.3 kg |
---|---|
Dimensions | 17 × 12 × 5 cm |
Based on 0 reviews
Be the first to review “UT 302A+ Infrared thermometer”
-
Thermal Imagers
UTi 120T Thermal Imager
Advantages of thermal imager detection:
1. Intuitive, efficient and convenient, making users directly “see” the temperature variation.
2. Thermal condition of different locations for comprehensive analysis, providing more information for judgment
3. Avoiding judgment errors, reducing labor costs, and discovering poor heat dissipation and hidden trouble points
4. PC software for data analysis and report output
SKU: n/a -
Rework & Soldering Station
YH 852 (BRUSHLESS FAN) Rework Station
Machine parameter Rated voltage AC 220V±10% 50Hz Machine power 700W±10%(MAX) working environment 0~40℃ relative humidity <80% Storage temperature -20~80℃ relative humidity <80% Machine size 25.5*18.8*12.5cm weight 3.55KG Part of performance parameters Hot air gun Soldering iron Working voltage AC 220V±10% 50Hz AC 26V±10% 50Hz Output power 650W 60W temperature range 100℃~500℃ 200℃~500℃ Mode of airflow brushless fan — airflow 120L/min(max) — Temperature stability ±15℃ (static) ±10℃ (static) Display two LED (red/green) — heater Heating core ceramics heater common heater Tips to ground impedance — <2Ω Tips voltage to ground — <2mV SKU: n/a -
Laser Distance Meters
LM 570LD-I Laser Level Meter
Laser Type 1V1H Expanded Angle H110°/V110° Laser Class 2 Light Source 10 mW Laser Wavelength 510 nm H/V Accuracy ±3 mm/10 m Self-leveling Range 3°±1° Self-leveling Time 3 s Working Distance 20 m-40 m Operating Time >4 h Power AA battery (LR6) × 2 pcs. Operating Temperature from -10°C to +40°C Storage Temperature from -20°C to +70°C Dimensions 59 mm × 28 mm × 137 mm Weight 170 g SKU: n/a -
Laser Distance Meters
LM 120PRO Laser Distance Meter
Specifications LM120PRO Display type EBTN Display size 2.4-inches Range 120m Min. display unit 0.001m Measurement units m/ft/in/ft+in Measurement basis Front/middle/rear Accuracy ±2mm Laser class 2 Laser type 630~670nm, ﹤1mW Features Single measurement √ Continuous measurement √ Max/Min/Area √ Volume/Pythagoras √ Add/Subtract/Triangle area √ Auto leveling horizontal/vertical √ Electronic leveler √ Data storage 20 groups Auto laser off 30s without operation Auto power off √ Auto backlight off √ Battery status display √ USB charging √ Tripod mounting hole √ General Characteristics Power 1.2V AAA recharge battery x 3 Product color Red and grey Product net weight 170g Product size 59mm x 28mm x 137mm Standard accessories Carrying bag, USB interface cab Standard individual packing Gift box, English manual Standard quantity per carton 20pcs Standard carton measurement 390mm x 255mm x 345mm Standard carton gross weight 8.3kg SKU: n/a -
Multimeters
UT61D+ Digital Multimeter
Specifications Range UT61D+ Safety ratings CAT III 1000V/CAT IV 600V AC voltage (V) 1000V ±(1%+3) DC voltage (V) 1000V ±(0.5%+3) AC current (A) 20A ±(1.2%+5) DC current (A) 20A ±(1%+2) Resistance (Ω) 60MΩ ±(1%+2) Capacitance (F) 60mF ±(3%+5) Frequency (Hz) 10MHz ±(0.1%+4) Duty cycle (%) 0.1%~99.9% ±(2%+5) Temperature (℃/℉) -40℃~1000℃ ±(1%+3) -40℉~1832℉ ±(1%+6) Display count 6000 Bandwidth (Hz) 40Hz~1kHz LoZ ACV √ Peak Hold √ Analog bar 31 General Characteristics Power 1.5V battery (R03) x 4 Product net weight 350g Product size 190mm x 90mm x 50mm Standard accessories Battery, gold plated test leads, USB cable, temperature probe, English manual Standard individual packing Gift box, cloth bag Standard quantity per carton 20pcs Standard carton measurement 480mm x 370mm x 365mm Standard carton gross weight 15.2kg Optional accessories Bluetooth/APP SKU: n/a
There are no reviews yet.