-3%

UT120C Pocket Size Type Digital Multimeters

Availability:

20 in stock


Main Features

1. Auto range

2. Auto polarity indication

3. Relative mode

4. Data hold

5. Auto power off

6. Capacitance measurement

7. AC/DC current measurement

8. Complies with CE (European Union) directives

5,040 5,214

20 in stock

Compare

Main Features

1. Auto range

2. Auto polarity indication

3. Relative mode

4. Data hold

5. Auto power off

6. Capacitance measurement

7. AC/DC current measurement

8. Complies with CE (European Union) directives

Category:
Weight 0.1 kg
Dimensions 11 × 6 × 11 cm
Specifications Range Best Accuracy
Model UT120C 
DC Voltage (V) 4V/40V/400V/600V ±(0.8%+3)
AC Voltage (V) 4V/40V/400V/600V ±(1.2%+3)
DC Current (A) 400μA/4mA/40mA/400mA ±(1.0%+3)
AC Current (A) 400μA/4mA/40mA/400mA ±(1.5%+5)
Resistance (Ω) 400Ω/4KΩ/40KΩ/400KΩ/4MΩ/40MΩ ±(1%+2)
Capacitance (F) 4nF/40nF/400nF/4μF/40μF/100μF ±(4%+3)
Frequency (Hz) 99.99Hz~99.99KHz ±(0.5%+3)
Features
Display Count 4000
Auto Range
Duty Cycle 0.1%~99.9%
Diode
Auto Power Off Around 30 Minutes
Continuity Buzzer
Low Battery Indication ≤2.4V
Data Hold
Relative Mode
Input Impedance for DCV Around 10MΩ
General Characteristic 
Power 3V Battery(CR2032)
LCD Size 43mm X 22mm
Product Color Red and Grey
Product Net Weight 76g
Product Size 110mm X 58.2mm X 10.8mm
Standard Accessories Battery,Carrying Case
Standard Individual Packing Blister, English Manual
Standard Quantity Per Carton 90 PCs
Standard Carton Measurement 528mm X 323mm X 400mm (0.068 CBM Per Export Carton)
Standard Carton Gross Weight 13.5 Kg

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT120C Pocket Size Type Digital Multimeters”

There are no reviews yet.

  • UT12D-US AC Voltage Detector

    0 out of 5
    (0)

    features:
    1. Auto power off
    2. Buzzer
    3. LED indication
    4. AC voltagedetection
    5. High/Low voltagemode

    Applications:
    Low voltage mode: Low-voltage motor (<90V), audio systems, arc welding machines,underground mining lighting, cables with thick insulation layer and other weakelectromagnetic AC signals.
    High voltage mode: Urban electric supply and three-phase systems (90~1000V). Forexample, power distribution units, electrical panels, electrical appliances.

    SKU: n/a
  • ET 8133 DMM

    0 out of 5
    (0)

    Product description

    3 times/second
    Diode: YES
    Capacitance: YES
    True RMS: YES
    Data hold: YES
    Backlight: YES
    Flashlight: YES
    Auto power off: YES (no measurement operation within 15 minutes)
    Low battery indication: YES
    Environment temperature: 0~40℃, humidity <75%
    Storage environment: -20~60℃, humidity <80%
    DC voltage:
    Range: 200mV/2.000V/20.00V/200.0V/600V
    Resolution: 0.0001V/0.001V/0.01V/0.1V/1V
    Accuracy: ±(0.5%+3)
    Max.: 600V
    AC voltage:
    Range: 2.000V/20.00V/200.0V/600V
    Resolution: 0.001V/0.01V/0.1V/1V
    Accuracy: ±(1.0%+3)
    Max.: 600V
    Capacitance:
    Range: 20.00nF/200.0nF/2.000F/200.0F
    Resolution: 0.01nF/0.1nF/10nF/100nF
    Accuracy: ±5%+3
    Max.: 200μF
    AC current:
    Range: 20mA/200mA, 2A, 10A
    Resolution: 0.1mA/0.001A/0.01A
    Accuracy:
    20mA/200mA/2A: ±(1.0%+3)
    10A: ±(1.5%+3)
    Max.:
    20mA/200mA: 200mA
    2A/10A: 10A
    DC current:
    Range: 20mA/200mA, 2A, 10A
    Resolution: 0.1mA/0.001A/0.01A
    Accuracy:
    20mA/200mA: ±(2.0%+4)
    2A: ±(1.0%+5)
    10A: ±(2.0%+3)
    Max.:
    20mA/200mA: 200mA
    2A/10A: 10A
    Resistance:
    Range: 2.000KΩ/20.00KΩ/200.0KΩ/2.000MΩ/20.00MΩ
    Resolution: 0.001KΩ/0.01KΩ/0.1KΩ/0.001MΩ/0.01MΩ
    Accuracy:
    2.000KΩ: ±(1.5%+3)
    20.00KΩ: ±(0.5%+3)
    200.0KΩ: ±(0.5%+3)
    2.000MΩ: ±(1.0%+3)
    20.00MΩ: ±(1.5%+3)
    Max.: 20MΩ
    Continuity: YES
    NCV: YES
    Frequency response in AC mode: 40Hz~1KHz
    LCD size: 45 * 25mm / 1.8 * 1.0in
    Item size: 124 * 65 * 26mm / 4.9 * 2.6 * 1.0in
    Item weight: 210g / 7.4ounce
    Package size: 140 * 100 * 40mm / 5.5 * 3.9 * 1.6in
    Package weight: 220g / 7.8ounce

    SKU: n/a
  • MIC-10 , 1000 V Insulation Tester

    0 out of 5
    (0)

    Insulation Resistance Meter

    SKU: n/a
  • TDR-420 Time Domain Reflectometer/ Cable Fault Locator

    0 out of 5
    (0)

    Product features

    • Possibility damage-free location of impedance changes of tested cables and wires such as:
      • shorted conductor,
      • open conductor / end of cable – useful during the inventory of warehouses and stores,
      • splice,
      • splitter,
      • water ingress,
      • wet splice,
      • bridge tap
      • or other changes.
    • Single measurement mode ONCE,
    • Continuously measurement mode CONT,
    • Tone signal generator TONE,
    • Two cursors to mark two places of damage along with an indication of the distance between them,
    • Built-in HELP function for easier interpretation of the reflectogram,
    • 11 available measuring ranges from 7 m to 6000 m,
    • „dead zone” limited to 0.6 m,
    • Color 3,5” LCD TFT display with resolution 320 x 240 pixels,
    • manually set of sensitivity in 8 steps GAIN,
    • output impedance regulation up to 200 Ω (possibility of measuring pre-insulated pipes),
    • Velocity of Propagation set in range from 10% to 99%,
    • tight and durable housing with IP67 ingress protection degree.
    • Small size and weight.
    SKU: n/a
  • MRU-30 Earth Resistance and Resistivity Meter

    0 out of 5
    (0)

     

    • It allows to take the measurements of:

      • earthing resistance using auxiliary electrodes,
      • earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
      • earthing resistance using double clamps for measuring multiple earthing without underground connections.
      • ground resistivity (Wenner method),
      • continuity of equipotential bondings and protective
      • conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.

      Additionally:

      • measurement of resistance of auxiliary electrodes RS and RH,
      • measurement of interference voltage,
      • measurement in the presence of interference voltage in the power network
      • with frequency 50Hz, 60Hz,
      • selection of maximum measuring voltage (25V and 50V),
      • introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
      • memory of 990 measurements (10 banks of 99 cells each),
      • calibration of clamp used,
      • data transmission to the computer (USB),
      • indication of battery state.
    SKU: n/a