UT18 series of test pen with measuring AC and DC voltage (including the three-phase alternating current) measurement, phase of three-phase AC power indicator, on-off test, RCD test, single pen measurement (can determine the zero line or wire), self checking, no battery detection and other functions.
Suitable for: smelting, electronics, manufacturing, defense, electric power, petroleum, chemical industry. Also used to solve complex problems of electronic, factory automation, power distribution and electrical equipment in.
UT18C Voltage And Continuity Testers
UT18 series of test pen with measuring AC and DC voltage (including the three-phase alternating current) measurement, phase of three-phase AC power indicator, on-off test, RCD test, single pen measurement (can determine the zero line or wire), self checking, no battery detection and other functions.
Suitable for: smelting, electronics, manufacturing, defense, electric power, petroleum, chemical industry. Also used to solve complex problems of electronic, factory automation, power distribution and electrical equipment in.
₨10,800 ₨13,000
Weight | 0.3 kg |
---|---|
Dimensions | 27 × 9 × 3 cm |
Specifications | Range | Best Accuracy |
Model | UT18C | |
LED AC/DC Voltage Indication (V) | 12V | 8V±2V |
24V | 18V±2V | |
50V | 38V±4V | |
120V | 92V±6V | |
230V | 174V±8V | |
400V | 320V±10V | |
690V | 550V±15V | |
Phase Rotation Test | Operating Voltage: 100V~690V | √ |
Frequency:50Hz~ 60Hz | ||
Single Lead(L2)Voltage Detection | Operating Voltage:100V~690V | √ |
Frequency: 50Hz~ 400Hz | ||
Continuity Test | Resistance: 0~100KΩ | √ |
Beeper and LED light Indicator | ||
RCD Test | Operating Voltage:230V(50Hz~400Hz) | √ |
Polarity Detection | Positive & Negative | √ |
Self-inspection | All LED or LCD indicator | √ |
No Power Test | Operating Voltage: 50VAC/120VDC~690VDC/AC | √ |
Features | ||
IP65 | √ | |
Auto Range | All Range | √ |
Exceed Voltage | Voltage Range:713V~788V | √ |
Auto standby | standby current <10uA | √ |
Silent mode | All Range | √ |
Work Light | All Range | √ |
Low Battery Indication | Voltage Range:2.2V~2.4V | √ |
LCD Display (Voltage+frequency) | 6V~ 690V (40Hz~400Hz) | ±(1.5%+5) |
General Characteristic | ||
Power | 1.5V Batteries(R03) × 2 | |
LCD Size | 31×20mm | |
Product Color | Red and Grey | |
Product Net Weight | 280g | |
Product Size | 272mm×85mm×31 mm | |
Standard Accessories | Batteries | |
Standard Individual Packing | Blister, English Manual | |
Standard Quantity Per Carton | 30PCs | |
Standard Carton Measurement | 440mm × 295mm × 455mm (0.079 CBM Per Standard Carton) | |
Standard Carton Gross Weight | 17.5Kg |
Based on 0 reviews
Be the first to review “UT18C Voltage And Continuity Testers”
-
Multimeters
UT195E Professional Digital Multimeters
Features
1. IP65 rating, 2m drop proof, CAT III 1000V, CAT IV 600V
2. Large 6000-count LCD screen
3. True RMS
4. ACV 750V 5kHz bandwidth
5. Flashlight
6. Auto LCD backlight controlled by light sensor (can be turned off)
7. LoZ voltage test, for ghost voltage measurement
8. 20A current measurement (max 30 seconds)
9. 31 analogue bar
SKU: n/a -
Process Celibrators
UT714 Multifunction Temperature Process Calibrator
Features of UT714 Multifunction Temperature Process Calibrator
Certifications: CE, UKCA
● Step/ramp functions
● Source and measure accuracy up to 0.02%● Rechargeable battery● Contrast adjustment● Auto power off (Time adjustable)● Stores and recalls setups● USB communicationSKU: n/a -
Clamp Meters
CMP-2000 Digital clamp-on multimeter
It provides:
- AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
- Measurement of INRUSH current in start-up phase of electrical device.
- AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
- Resistance measurement and continuity test:
– continuity test with acoustic signalling (beeper) for resistance below 30 Ω. - Capacitance measurement.
- Temperature measurement (Fahrenheit or Celsius).
- Frequency measurement.
- Duty cycle measurement.
- Diode test.
SKU: n/a -
Insulation Tester
MIC-5001, 5000V Insulation Tester
Insulation resistance measurement in a compact, light-weight, low-cost design.
- Measurement to 5 TΩ
- Measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps
- Continuous indication of insulation resistance or leakage current
- Automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement
- Audio beeps every five seconds to alert user test is proceeding, and to get time characteristics
- Measured test times of T1, T2 and T3 for measuring Absorption Coefficient, Dielectric Absorption Ratio DAR. and Polarization Index PI
- Continuous display of test voltage during the measurement
- Protection against measuring live objects
- Two and three-lead measurement method
- Ramp Test Insulation resistance measurement
- Measurement of breakdown voltage with increments up to 1 kV / s
- Measurement of alternating and direct voltages from 0 V to 750 V
- 990 cells of memory (11880 records) to record results
- Data transfer to PC via USB cable
- Built-in rechargeable battery pack
- Meets the requirements of the EN 61557 standard
- Charge from optional car lighter (12 V) socket accessory