-4%

UT201+ ACA Digital Clamp Meters


1. Auto range and 3/s sampling rate

2. Data hold

3. Max value hold

4. Auto power off

5. Low battery prompt, over-range prompt and auto polarity display

6. Comfortable tohold and easy to carry with (Product weight: 220g)

7. 1m drop proof

8. Complies with Double Insulationand Over Voltage standards of CAT II 600V, CAT III 300V and Pollution Degree 2

9. Complies with CE (European Union) directives

4,780 5,000

Compare

1. Auto range and 3/s sampling rate

2. Data hold

3. Max value hold

4. Auto power off

5. Low battery prompt, over-range prompt and auto polarity display

6. Comfortable tohold and easy to carry with (Product weight: 220g)

7. 1m drop proof

8. Complies with Double Insulationand Over Voltage standards of CAT II 600V, CAT III 300V and Pollution Degree 2

9. Complies with CE (European Union) directives

Category:
Weight 0.2 kg
Dimensions 21 × 8 × 3 cm
Specifications Range Best Accuracy
Model UT201
AC Current (A) 2A/20A/200A/400A ±(1.5%+5)
AC Voltage (V) 2V/20V/200V/600V ±(1.2%+5)
DC Voltage (V) 200mV/2V/20V/200V/600V ±(0.8%+1)
Resistance (Ω) 200Ω/2KΩ/20KΩ/200KΩ/2MΩ/20MΩ ±(1%+2)
Features
Display Count 2000
Auto Range
Jaw Capacity 28mm
Diode
Auto Power Off
Continuity Buzzer
Low Battery Indication
Data Hold
MAX Mode
Full Icon Display
Input Impedance for DCV Around 10MΩ
General Characteristic 
Power 1.5V Batteries(R03) ×2
LCD Size 35.6mm X 18 mm
Product Color Red and Grey
Product Net Weight 220g
Product Size 210mm X 75.6mm X30 mm
Standard Accessories Batteries, Test Lead,Carrying Bag
Standard Individual Packing Gift Box, English Manual
Standard Quantity Per Carton 40 PCs
Standard Carton Measurement 540mm X 495mm X 335mm   (0.09 CBM Per Standard Carton)
Standard Carton Gross Weight 23Kg

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT201+ ACA Digital Clamp Meters”

There are no reviews yet.

  • 2117R

    0 out of 5
    (0)

    Features of 2117R True RMS 1000A AC Clamp Meter

    Certificates: CE, UKCA

    ● True RMS

    ● 1000A AC current measurement
    ● 1000V AC/DC voltage measurement
    ● Large LCD with backlight
    ● ACA frequency measurement: 20H~10kHz
    ● 1000V overload protection
    ● NCV (High/Low dual-mode)
    SKU: n/a
  • CLAMP METER AC DC CM 2056

    0 out of 5
    (0)

    Technical data

    Basic function

    Range

    Accuracy

    DCV

    400mV/4V/40V/400V/1000V

    ±(0.5%+5)

    ACV

    400mV/4V/40V/400V/750V

    ±(1.0%+5)

    DCA

    400A/1000A

    ±(2.0%+5)

    ACA

    400A/1000A

    ±(2.0%+5)

    Resistance

    400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ

    ±(0.8%+3)

    Capacitance

    4nF/40nF/400nF/4uF/40uF/200uF

    ±(3.5%+8)

    Frequency

    100Hz/1kHz/10kHz/100kHz/1MHz/10MHz

    ±(0.5%+4)

    Temperature

    (-40~ 1000) ℃ / (-40 ~1832) ℉

    ±(1.0%+5)

    Special function

    CM-2056

    NCV test

    True RMS test

    Diode test

    Continuity test

    Less than 50Ω±10Ω

    Low battery indicator

    Approx. less than 2.4 V

    Data hold

    Auto power off

    About 15 minutes

    Function protection

    Clamp light

    Backlight display

    Input impedance

    10MΩ

    Sampling rate

    3 times/s

    AC frequency response

    Current 50-60Hz/ voltage 50-400Hz

    Operation method

    Auto or manual range

    Max display

    4000

    Clamp opens

    52mm

    Battery

    3V (2*AAA battery)

    General Characteristic

    Meter color

    Orange and Black

    Meter weight

    About 280g (including battery)

    Meter size

    270×123×50mm

    Standard accessory

    Test leads, battery, manual, TP01 temperature probe

    SKU: n/a
  • UT 196

    0 out of 5
    (0)

    1. True RMS
    2. Measure up to 1700V DC and 1500V AC for high voltage applications such as solar array, wind and other power utility maintenance
    3. Analog bar
    4. Frequency response:45Hz~1kHz
    5. IP65 protection
    6. CAT III 1000V, CAT IV 600V

    SKU: n/a
  • UNI-T MSO3154E 150MHz Mixed Signal 4 Channel Digital Oscilloscope

    0 out of 5
    (0)
    Analog bandwidth 150MHz 250MHz
    Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital
    Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels)
    Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels)
    Memory depth 70Mpts
    Waveform capture rate 200,000wfms/s
    Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display )
    Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall]
    Input impedance (1MΩ±1%) II (20pF±3pF)
    Input impedance digital (101kΩ±1%) II (9pF±1pF)
    Vertical scale 1mV/div~20 V/div (1 MΩ)
    DC gain accuracy <5mV: ±3%, ≥5mV: ±2%
    Waveform record 100,000 frames
    Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
    CAN, LIN, FlexRay
    Bus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay
    Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations
     

     

    Auto measurements

    Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
    -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
    channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A
    Measurement display 5 types
    Measurement statistics Average, Max, Min, standard deviation and number of measurements
    Frequency counter 6 bits
    Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA
     

     

    Standard Accessories

    USB interface cable UT-D14
    Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06
    Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05
    16CH Logic analyzer probe UT-15M

     

    SKU: n/a
  • PHASE INDICATOR KEW 8031

    0 out of 5
    (0)

    ・Two Functions in One Unit
    Presence of open phase can be checked by the lamps, and the phase
    sequence can be indicated by the rotating disk.

    ・ High Reliability
    measuring range for 3-phase installations from 110V to 600V.
    Sealed against dust ensures the trouble-free performance.

    ・ Battery-free tester

    SKU: n/a