UT622A Digital Inductance LCR Meter


Specifications UT622A UT622C UT622E
Certificates CE, RoHS
Test frequency 100Hz, 120Hz, 1kHz, 10kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz
Test signal level  0.1Vrms, 0.3Vrms, 1Vrms
Output impedance 100Ω
Measurement parameters Primary: L/C/R/Z
Secondary: D/Q/θ/ESR
Primary: L/C/R/Z/DCR  Secondary: D/Q/θ/ESR
Auto LCR
Test terminals Three-terminal test jacks, five-terminal test sockets
Test rate Fast (20 times/s), medium (5 times/s), or slow (2 times/s)
DCR test rate Fast (20 times/s), medium (5 times/s), or slow (2 times/s)
Ranging mode Auto/hold
Tolerance range 1%~20%
Testing circuit mode Series/parallel mode
Clearing correction Open/short circuit
Fuse of test ports 0.1A/250V
Communication interface Mini-USB
LED alarm for tolerance
(pass: green; fail: red)
Display range
Maximum reading 99999
Minimum resolution 0.0001
Maximum accuracy 0.001
L 0.00μH~99.999H
C 0.00pF~99.999mF
Z/R 0.0000Ω~9.9999MΩ
ESR 0.0000Ω~999.99Ω
D 0.0000~9.9999
Q 0.0000~99999
θ -179.9°~179.9°
DCR 0.01mΩ–20.000MΩ
Temperature coefficient 0.1× (specified accuracy) /°C (0°C~18°C or 28°C~40°C)
General Characteristics
Power 3.7V 1800mAh lithium polymer battery; Input: 220V (1±10%), 50Hz (1±5%); Mini-USB output: 5V, 1A
Display 2.8′ TFT LCD 320X240
Product net weight 420g
Product size 93mm x 192mm x 44mm
Standard accessories Short circuit board (UTR-001), USB cable, 5V 1A power adapter, Four-terminal Kelvin testleads (UTR-L100k-H) (UT622C/E), Alligator clip test leads with rubber plugs (UTR-002)(UT622A), English manual

57,410

Compare

UT622A Digital Inductance LCR Meter

Precision LCR Meter – Up to 0.1% high accuracy measurements, the unit mainly measures inductance (L), capacitance (C), resistance (R) of components, also measures impedance (Z), dissipation factor (D), quality factor (Q), angle phase (θ), and ESR.
Accurate Measurement – Selectable 4 test frequencies of 100Hz, 120Hz, 1kHz, and 10kHz. Selectable 3 test levels of 0.1V, 0.3V, and 1V. Selectable tolerance of 1%, 5%, 10%, and 20%. Able to select parallel or series increasing accuracy of in-circuit testing. Auto-off in 5min, 15min(default), 30min, or 60min are selectable.
3 Measurement Speeds – Slow(2 times per second), medium(5 times per seconds) and fast(20 times per second).
Tolerance Comparison – Equipped with audible/visual alarm, and counter features for tolerance fail/pass test.
Data Logger – The average, maximum, minimum value can be recorded via data logging mode.
Zeroing – Open/short zeroing eliminates connection errors, deliver more accurate measurement each times.
USB to PC – Transfer data to the PC/Laptop through a USB port, and exports to image file(jpg.), Excel and PDF report is available.
Portable – High resolution LCD with 5 digit display, lightweight, portable, and battery operated.
Applied in the product development, incoming inspections, or production line testing.

Category:

Brand

UNI T

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “UT622A Digital Inductance LCR Meter”

There are no reviews yet.

  • UNI-T 2 Channel UPO2102E Ultra Phosphor Oscilloscope

    0 out of 5
    (0)
    • 100MHz bandwidth
    • number of channels 2
    • sampling 1GS / s
    • max memory depth 56Mpts (per channel) (previously 28Mpts per channel)
    • waveforms per second up to 80,000 wfms/s (formerly 50,000 wfms/s)
    • time base range 5ns/div – 50s/div
    • input coupling (1MΩ ± 2%) // (20pF ± 3pF)
    • verical axis 1mV/div – 20V/div (1MΩ)
    • DC gain accuracy ± 3%
    • number of saved waveforms 65000
    • trigger : Edge, Window, Runt, Time Out, Nth Edge, Delay, Duration, Setup / Hold, Pulse Width, Slope, Video, Pattern, RS232 / UART, I2C, SPI
    • mathematical operations with waveforms : A + B, A-B, AxB, A / B, FFT, Logic operation, Editable Advanced, Filter
    • automatic Measurement : Max, Min, High, Low, Middle, Pk-Pk, Ample, Mean, Cycle Mean, RMS, Cycle RMS, Cycle Area, OverShoot, PreShoot, Period, Freq, Rise, Fall, + Width, -Width, + Duty, -Duty, RiseDelay, FallDelay, Phase, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF
    • number of measurements : 5 simultaneous measurements
    • statistics : Mean, Max, Min, standard deviation, number of measurements
    • frequency counter : 6 bits
    • standard interfaces : USB-Host, USB-Device, LAN, AUX (Trig Out, Pass / Fail)
    SKU: n/a
  • UNI-T UTL8212 High-Precision Compact DC Electronic Load Tester Single/Dual Channel 150V Power Supply Current Test – UTL821

    0 out of 5
    (0)

    Power supply test, adapter/charger test, battery test, lithium battery protection board test, ATE, component test, etc., commonly used in home appliance manufacturers, LCD and other computer component manufacturers, switching power supply and LED manufacturers, adapter charger manufacturers and other companies Production and testing use

    SKU: n/a
  • MC TIP 900M TI

    0 out of 5
    (0)
    SKU: n/a
  • UT714 Multifunction Temperature Process Calibrator

    0 out of 5
    (0)

    The UT714 is powerful temperature calibrator that sources and measures thermocouples, RTDs, voltage, and resistance. It can be used to test and calibrate diffrent types of temperature instruments. This device is suitable for testing input/output temperature terminals such as sensors and transmitters.

    SKU: n/a
  • UT195E Professional Digital Multimeters

    0 out of 5
    (0)

    Features

    1. IP65 rating, 2m drop proof, CAT III 1000V, CAT IV 600V

    2. Large 6000-count LCD screen

    3. True RMS

    4. ACV 750V 5kHz bandwidth

    5. Flashlight

    6. Auto LCD backlight controlled by light sensor (can be turned off)

    7. LoZ voltage test, for ghost voltage measurement

    8. 20A current measurement (max 30 seconds)

    9. 31 analogue bar

    SKU: n/a
  • JAKEMY JM-6032 Interchangeable Precise Manual Tool Set

    0 out of 5
    (0)

    JAKEMY JM-6032 Interchangeable Precise Manual Tool Set

    SKU: n/a