The UTG9000C-II Series Function/Arbitrary Waveform Generator uses the direct digital synthesis technology, which can generate the accurate, stable,
UTG9005C-II Function/Arbitrary Waveform Generato
Out of stock
1. Output waveforms: Sine, square, ramp, pulse, noise, DC, arbitrary
₨47,742 ₨52,716
Out of stock
CompareWeight | 3 kg |
---|---|
Dimensions | 24 × 32 × 10 cm |
Specifications | |
Model | UTG9005C-II |
Channel | 1 |
Bandwidth | 5MHz |
Sampling rate | 125MS/s |
Vertical resolution | 14 bits |
Waveforms | Sine, square, pulse, ramp, noise, DC, arbitrary (20 sets inside ) |
Sweep modes | Logarithmic, linear |
Frequency Characteristics | |
Sine | 1μHz~2MHz |
Square | 1μHz~2MHz |
Ramp | 1μHz~200kHz |
Pulse | 1μHz~2MHz |
Arbitrary | 1μHz~1MHz |
Resolution | 1μHz |
Accuracy | Within 90 days ± 50ppm |
Within 1 year ± 100ppm | |
18℃~28℃ | |
Output Characteristics | |
Impedance | 50Ω/High Z |
Amplitude range | 1mVpp~10Vpp (50Ω); 2mVpp~20Vpp (high Z) |
DC offset range | -5Vpp~5Vpp (50Ω) (AC+DC); -10Vpp~10Vpp (high Z) (AC+DC) |
Amplitude resolution | 1mV |
General Characteristics | |
Power | 100~240VAC, 50Hz/60Hz |
Display | EBTN LCD |
Product color | White and grey |
Product net weight | 2.8kg |
Product size | 265mm x 110mm x 320mm |
Standard accessories | USB interface cable, power cord, BNC cable with alligator clips , PC software CD |
Standard individual packing | Carton box |
Standard quantity per carton | 2pcs |
Standard carton measurement | 380mm x 330mm x 320mm |
Standard carton gross weight | 7kg |
Based on 0 reviews
Be the first to review “UTG9005C-II Function/Arbitrary Waveform Generato”
-
Power Quality Analyzer
PQM-707 Power Quality Analyzer
-
Features:
- 7″ touch screen – intuitive operating
- CAT IV 600V – high safety
- all parameters acc. to class S – high accuracy of measurements
- Li-Ion rechargeable battery – higher mobility
- removable memory card – recording data with no restrictions
Possible measurements:
- Measurements according to EN 50160,
- Voltage L1, L2, L3, N-PE (five inputs),
– average, minimum, maximum values, range to 760 V, ability to work with voltage transformers, - Current L1, L2, L3, N (four inputs),
– average, minimum, maximum values, measurement current with range to 3 kA (depends on used clamp), ability to work with current transformers, - Crest factor for voltage and current,
- Frequency from 40 Hz to 70 Hz ,
- Active, reactive, distortion, apparent power, including the type of reactive power (capacitive, inductive),
- Power recording:
- Budeanu method,
- IEEE 1459,
- Active, reactive, apparent energy,
- Power factor, cosφ, tgφ,
- Up to 50th harmonics for voltage and current,
- Total Harmonic Distortion (THD) for voltage and current,
- Short-term (PST) and long-term (PLT) flicker,
- Unbalance of voltage and current,
- Current and voltage events registration including waveforms and RMS graphs half period,
- Inrush current
- Calculator of energy tariffs
- ANALYZER MEASURES AND RECORDS ACCORDING TO THE IEC 61000-4-30 CLASS S STANDARD.
SKU: n/a -
-
DC Power Supplies
TITAN TN 305DS DC Power Supply
Operating Conditions
Supply power: AC 220-240V, 50Hz/60Hz.
Working Temperature: -10°C ~ 40 °C
Relative Humidity: ‹ 90%
Storage Conditions: -10°C ~ 40 °C
Relative Humidity: ‹ 80%
Stable Voltage
The output voltage is between 0 and nominal value continuously adjustable
Voltage Stability: ≤0.01% +2mV
Load Stability: ≤ 0.01% +2mV
Recovery Time: ≤100µS
Temperature Coefficient: ≤ 200PPM/°C
Ripple Noise: ≤1 MVRMS(RMS)
Stable CurrentPower Stability: 0.1% + 3mA
Load Stability: 0.2% + 3mA
Ripple Noise : ≤2mArms(RMS)
The output current is between 0 and nominal value continuously adjustable
SKU: n/a -
Earth Ground Resistance Testers
MRU-30 Earth Resistance and Resistivity Meter
-
It allows to take the measurements of:
- earthing resistance using auxiliary electrodes,
- earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
- earthing resistance using double clamps for measuring multiple earthing without underground connections.
- ground resistivity (Wenner method),
- continuity of equipotential bondings and protective
- conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.
Additionally:
- measurement of resistance of auxiliary electrodes RS and RH,
- measurement of interference voltage,
- measurement in the presence of interference voltage in the power network
- with frequency 50Hz, 60Hz,
- selection of maximum measuring voltage (25V and 50V),
- introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
- memory of 990 measurements (10 banks of 99 cells each),
- calibration of clamp used,
- data transmission to the computer (USB),
- indication of battery state.
SKU: n/a -
There are no reviews yet.