A12T/13T measures real-time temperature and humidity and display readings on a large screen. These can be used for both indoor and outdoor measurements. A12T has an additional external sensor probe for measuring temperatures of two locations. Both of these meters have alarm clock and 12/24 time mode. A12T displays comfort rating based on the combination of temperature and humidity. Hanging hole and stand are available for wall or table mount
A13T Temperature Humidity Meter
30 in stock
1. Sampling time: 10s
₨3,120 ₨3,500
30 in stock
CompareWeight | 0.1 kg |
---|---|
Dimensions | 13 × 2 × 8 cm |
Based on 0 reviews
Be the first to review “A13T Temperature Humidity Meter”
-
Wire & Cable Testers
UT681HDMI Cable Tester
1. Tests HDMI/MINI-HDMI cables
2. Fastline collocation type: A with A, A with C and C with C
3. Checks circuit breakage, short circuit, cross circuit and the missing wire
4. 20 visible LED indicators
5. Can toggle between scan and full display test modes
6. Single key operation
7. Manual/auto power off (after 10-minute inactivity)
8. Low battery indication
9. CE certification
10. Power supplied by 9V layer-built battery
SKU: n/a -
Analog Multimeters
ANALOG METER YX 360TR BS
Features Of Handheld YX-360TRE-B Analog Meter Voltmeter:
- High accuracy analogue multimeter for general purposes.
- Mirrored needle indicator with an accurate reading.
- Check both AC and DC parameters with continuity buzzer on Ohms.
- Up to 1000V on both AC and DC Voltage.
- 19 versatile ranges for general-purpose testing.
- Fuse & Diode protection.
- Compact sizing.
- Tilt back-stand.
- The large and mirrored scale of 80mm length.
SKU: n/a -
Clamp Meters
UT213C ACA DCA Digital Clamp Meters
Main Features
1. 10A/400A AC/DC measurement with Hall-effect sensor
2. Auto range makes measurement faster and more effective
3. 4000 display count, 3/s sampling rate
4. True RMS measurement
5. NCV, Non-Contact AC Voltage testing
6. Frequency and duty ratio measurement
7. MAX/MIN mode
8. Relative mode
9. Flashlight function for measuring at night or in the dark
10. K-type point contact temperature probe for temperature measurement
11. Large jaw of 30mm
12. Data hold
13. LCD backlight
14. Auto power off
15. 1m drop proof
16. Complies with CE (European Union) directives
SKU: n/a -
LCR Meter
UT622A Digital Inductance LCR Meter
Specifications UT622A UT622C UT622E Certificates CE, RoHS Test frequency 100Hz, 120Hz, 1kHz, 10kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz 100Hz, 120Hz, 1kHz, 10kHz, 100kHz Test signal level 0.1Vrms, 0.3Vrms, 1Vrms Output impedance 100Ω Measurement parameters Primary: L/C/R/Z
Secondary: D/Q/θ/ESRPrimary: L/C/R/Z/DCR Secondary: D/Q/θ/ESR Auto LCR √ Test terminals Three-terminal test jacks, five-terminal test sockets Test rate Fast (20 times/s), medium (5 times/s), or slow (2 times/s) DCR test rate — — Fast (20 times/s), medium (5 times/s), or slow (2 times/s) Ranging mode Auto/hold Tolerance range 1%~20% Testing circuit mode Series/parallel mode Clearing correction Open/short circuit Fuse of test ports 0.1A/250V Communication interface Mini-USB LED alarm for tolerance
(pass: green; fail: red)√ √ √ Display range Maximum reading 99999 Minimum resolution 0.0001 Maximum accuracy 0.001 L 0.00μH~99.999H C 0.00pF~99.999mF Z/R 0.0000Ω~9.9999MΩ ESR 0.0000Ω~999.99Ω D 0.0000~9.9999 Q 0.0000~99999 θ -179.9°~179.9° DCR — — 0.01mΩ–20.000MΩ Temperature coefficient 0.1× (specified accuracy) /°C (0°C~18°C or 28°C~40°C) General Characteristics Power 3.7V 1800mAh lithium polymer battery; Input: 220V (1±10%), 50Hz (1±5%); Mini-USB output: 5V, 1A Display 2.8′ TFT LCD 320X240 Product net weight 420g Product size 93mm x 192mm x 44mm Standard accessories Short circuit board (UTR-001), USB cable, 5V 1A power adapter, Four-terminal Kelvin testleads (UTR-L100k-H) (UT622C/E), Alligator clip test leads with rubber plugs (UTR-002)(UT622A), English manual SKU: n/a -
Earth Ground Resistance Testers
MRU-30 Earth Resistance and Resistivity Meter
-
It allows to take the measurements of:
- earthing resistance using auxiliary electrodes,
- earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
- earthing resistance using double clamps for measuring multiple earthing without underground connections.
- ground resistivity (Wenner method),
- continuity of equipotential bondings and protective
- conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.
Additionally:
- measurement of resistance of auxiliary electrodes RS and RH,
- measurement of interference voltage,
- measurement in the presence of interference voltage in the power network
- with frequency 50Hz, 60Hz,
- selection of maximum measuring voltage (25V and 50V),
- introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
- memory of 990 measurements (10 banks of 99 cells each),
- calibration of clamp used,
- data transmission to the computer (USB),
- indication of battery state.
SKU: n/a -
There are no reviews yet.