-8%

CMP-1006 Digital Clamp-on multimeter

Availability:

5 in stock


 

Additionally:

  • safe, insulated measuring clamps,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • DC ZERO mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored zero value,
  • MAX/MIN function,
  • over range indication,
  • AUTO-OFF function.

31,587 34,221

5 in stock

Compare

(TRUE RMS) up to 1000 A.

Measurement of INRUSH current in start-up phase of electrical device (high frequency of sampling)

AC/DC voltage measurement (TRUE RMS) up to 600 V.

Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 40.

Temperature measurement (Fahrenheit and Celsius units).

Frequency measurement.

Duty cycle measurement.

Diode test.

Category:
Weight 0.3 kg
Dimensions 23 × 8 × 5 cm

Electric security:

  • measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

 

Other technical data:

  • power supply: 9 V battery type 6LR61
  • display: 6600 counts, backlit LCD
  • continuity test: threshold 40 Ω; test current < 0,5 mA
  • diode test: test current of 0,3 mA, typical open circuit voltage < 3 V DC, typical
  • low battery indication: BAT displayed
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • INRUSH: integration time 100 ms
  • temperature sensor: type K thermocouple
  • input impedance: 10 MΩ (V DC and V AC)
  • AC bandwidth: 50…400 Hz (A AC and V AC)
  • auto power OFF: approx. 25 min.
  • dimensions: 229 x 80 x 49 mm
  • weight: 303 g
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
  • quality standard: ISO 9001

 

Rated operational conditions:

  • internal clamp diameters: d1 = 36 mm/d2 = 52 mm
  • operating temperature: +5…+40°C
  • storage temperature: -20…+60°C
  • operating humidity: max 80% up to 31°C decreasing linearly to 50% at 40°C
  • storage humidity: <80%
  • operating altitude: max 2000 m

 

AC/DC current measurement (TRUE RMS)

Range Resolution Accuracy (DC) Accuracy (AC)
0…659,9 A 0,1 A ±(2,5% m.v. +5 dgt) ±(2,5% m.v + 8 dgt) for f = 50…60 Hz
660…1000 A 1 A ±(2,8% m.v. +8 dgt) ±(2,8% m.v. + 8 dgt) for f = 50…60 Hz

 

DC voltage measurement

Range Resolution Accuracy
0…6,599 V 0,001 V ±(1,5% m.v. + 3 dgt)
6,60…65,99 V 0,01 V ±(1,5% m.v. + 3 dgt)
66,0…600,0 V 0,1 V ±(1,5% m.v. + 3 dgt)

 

AC voltage measurement (TRUE RMS)

Range Resolution Accuracy
0…6,599 V 0,001 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz
6,60…65,99 V 0,01 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz
66,0…600,0 V 0,1 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz

 

Resistance measurement

Range Resolution Accuracy
0,0…659,9 Ω 0,1 Ω ±(1,0% m.v. + 4 dgt)
0,660…6,599 kΩ 0,001 kΩ ±(1,5% m.v. + 2 dgt)
6,60…65,99 kΩ 0,01 kΩ ±(1,5% m.v. + 2 dgt)
66,0…659,9 kΩ 0,1 kΩ ±(1,5% m.v. + 2 dgt)
0,660…6,599 MΩ 0,001 MΩ ±(2,5% m.v. + 3 dgt)
6,60…66,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 dgt)

 

Frequency measurement

Range Resolution Accuracy
30,0…999,9 Hz 0,1 Hz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle
1,000…9,999 kHz 0,001 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle
10,00…15,00 kHz 0,01 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle

 

Temperature measurement

Range Resolution Accuracy
-20…760°C 0,1°C ±(3,0% m.v. + 5°C)
-4…1400°F 0,1°F ±(3,0% m.v. + 9°F)

 

Duty cycle measurement

Range Resolution Accuracy
10,0…94,9% 0,1% ±(1,2% m.v. + 2 dgt)
  • pulse width: 100μs…100 ms,
  • frequency range: 30 Hz…5 kHz,
  • sensitivity: 30 Hz…5 kHz: 10 Vrms, 5 kHz…15 kHz: 40 Vrms.

 

„m.v.”- measured value

 

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-1006 Digital Clamp-on multimeter”

There are no reviews yet.

  • UNI-T MSO3254E 250MHz Mixed Signal 4 Channel Digital Oscilloscope

    0 out of 5
    (0)
    Analog bandwidth 150MHz 250MHz
    Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital
    Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels)
    Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels)
    Memory depth 70Mpts
    Waveform capture rate 200,000wfms/s
    Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display )
    Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall]
    Input impedance (1MΩ±1%) II (20pF±3pF)
    Input impedance digital (101kΩ±1%) II (9pF±1pF)
    Vertical scale 1mV/div~20 V/div (1 MΩ)
    DC gain accuracy <5mV: ±3%, ≥5mV: ±2%
    Waveform record 100,000 frames
    Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
    CAN, LIN, FlexRay
    Bus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay
    Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations
     

     

    Auto measurements

    Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
    -Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
    channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→A
    Measurement display 5 types
    Measurement statistics Average, Max, Min, standard deviation and number of measurements
    Frequency counter 6 bits
    Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA
     

     

    Standard Accessories

    USB interface cable UT-D14
    Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06
    Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05
    16CH Logic analyzer probe UT-15M

     

    SKU: n/a
  • MC TIP 900M TFC

    0 out of 5
    (0)
    SKU: n/a
  • UT333S Digital Temperature Humidity Meter

    0 out of 5
    (0)

    1. Precise temperature and humidity sensor

    2. Split type design with extendable spring cable for convenient measurement
    3. LCD screen
    4. Sampling time: 1s
    SKU: n/a
  • UT120A Pocket Size Type Digital Multimeters

    0 out of 5
    (0)

    Main Features

    1. Auto range

    2. Auto polarity indication

    3. Relative mode

    4. Data hold

    5. Auto power off Function

    6. Capacitance measurement

    7. Complies with CE (European Union) directives

    SKU: n/a
  • UDP1306C Industrial Linear DC Power Supply

    0 out of 5
    (0)

    Features of UDP1306C Industrial Linear DC Power Supply:

    • 4-digit high precision display
    • OVP OCP OTP protection
    • Output setting viewable
    • Remote control (output ON/OFF)
    • Shutdown memory/keypad lock
    • Intelligent cooling fan
    • USB charging interface
    • RS232 program-controlled communication
    • USB device communication
    • 5 sets of data storage
    SKU: n/a