-8%

CMP-1006 Digital Clamp-on multimeter

Availability:

5 in stock


 

Additionally:

  • safe, insulated measuring clamps,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • DC ZERO mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored zero value,
  • MAX/MIN function,
  • over range indication,
  • AUTO-OFF function.

31,587 34,221

5 in stock

Compare

(TRUE RMS) up to 1000 A.

Measurement of INRUSH current in start-up phase of electrical device (high frequency of sampling)

AC/DC voltage measurement (TRUE RMS) up to 600 V.

Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 40.

Temperature measurement (Fahrenheit and Celsius units).

Frequency measurement.

Duty cycle measurement.

Diode test.

Category:
Weight 0.3 kg
Dimensions 23 × 8 × 5 cm

Electric security:

  • measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

 

Other technical data:

  • power supply: 9 V battery type 6LR61
  • display: 6600 counts, backlit LCD
  • continuity test: threshold 40 Ω; test current < 0,5 mA
  • diode test: test current of 0,3 mA, typical open circuit voltage < 3 V DC, typical
  • low battery indication: BAT displayed
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • INRUSH: integration time 100 ms
  • temperature sensor: type K thermocouple
  • input impedance: 10 MΩ (V DC and V AC)
  • AC bandwidth: 50…400 Hz (A AC and V AC)
  • auto power OFF: approx. 25 min.
  • dimensions: 229 x 80 x 49 mm
  • weight: 303 g
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
  • quality standard: ISO 9001

 

Rated operational conditions:

  • internal clamp diameters: d1 = 36 mm/d2 = 52 mm
  • operating temperature: +5…+40°C
  • storage temperature: -20…+60°C
  • operating humidity: max 80% up to 31°C decreasing linearly to 50% at 40°C
  • storage humidity: <80%
  • operating altitude: max 2000 m

 

AC/DC current measurement (TRUE RMS)

Range Resolution Accuracy (DC) Accuracy (AC)
0…659,9 A 0,1 A ±(2,5% m.v. +5 dgt) ±(2,5% m.v + 8 dgt) for f = 50…60 Hz
660…1000 A 1 A ±(2,8% m.v. +8 dgt) ±(2,8% m.v. + 8 dgt) for f = 50…60 Hz

 

DC voltage measurement

Range Resolution Accuracy
0…6,599 V 0,001 V ±(1,5% m.v. + 3 dgt)
6,60…65,99 V 0,01 V ±(1,5% m.v. + 3 dgt)
66,0…600,0 V 0,1 V ±(1,5% m.v. + 3 dgt)

 

AC voltage measurement (TRUE RMS)

Range Resolution Accuracy
0…6,599 V 0,001 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz
6,60…65,99 V 0,01 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz
66,0…600,0 V 0,1 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz

 

Resistance measurement

Range Resolution Accuracy
0,0…659,9 Ω 0,1 Ω ±(1,0% m.v. + 4 dgt)
0,660…6,599 kΩ 0,001 kΩ ±(1,5% m.v. + 2 dgt)
6,60…65,99 kΩ 0,01 kΩ ±(1,5% m.v. + 2 dgt)
66,0…659,9 kΩ 0,1 kΩ ±(1,5% m.v. + 2 dgt)
0,660…6,599 MΩ 0,001 MΩ ±(2,5% m.v. + 3 dgt)
6,60…66,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 dgt)

 

Frequency measurement

Range Resolution Accuracy
30,0…999,9 Hz 0,1 Hz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle
1,000…9,999 kHz 0,001 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle
10,00…15,00 kHz 0,01 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle

 

Temperature measurement

Range Resolution Accuracy
-20…760°C 0,1°C ±(3,0% m.v. + 5°C)
-4…1400°F 0,1°F ±(3,0% m.v. + 9°F)

 

Duty cycle measurement

Range Resolution Accuracy
10,0…94,9% 0,1% ±(1,2% m.v. + 2 dgt)
  • pulse width: 100μs…100 ms,
  • frequency range: 30 Hz…5 kHz,
  • sensitivity: 30 Hz…5 kHz: 10 Vrms, 5 kHz…15 kHz: 40 Vrms.

 

„m.v.”- measured value

 

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-1006 Digital Clamp-on multimeter”

There are no reviews yet.

  • UT301C Infrared Thermometers

    0 out of 5
    (0)

    UT301 series is a professional infrared thermometer that can determine the temperature by testing the infrared energy on the surface. It is used for fast and safe fault detections and maintenance of electric instrument and equipment, engines, motors, and HVAC refrigeration system.

    SKU: UN30C1550CIR
  • YH S218A PIPE

    0 out of 5
    (0)
    SKU: n/a
  • JM-6092B Home CR-V Rechargeable Screwdriver Set Supplier

    0 out of 5
    (0)

    Features:

    • Portable box with transparent cover.
    • Adjustable screwdriver bits.
    • Non-slip handle is made of PP & TPR material.
    • H4*60 mm magnetic extension bar.
    SKU: n/a
  • Digital Clamp Meter UT202+ UNI-T

    0 out of 5
    (0)
    Specifications Range UT202+
    AC current (A) 400A ±(2%+10)
    600A
    AC current frequency (Hz) 50Hz~100Hz ±(1%+5)
    AC voltage (V) 600V ±(0.8%+5)
    AC voltage frequency(Hz) 10Hz~10kHz ±(1%+5)
    10Hz~60kHz
    Resistance (Ω) 40MΩ ±(0.8%+2)
    60MΩ
    Capacitance (F) 4mF ±(4%+5)
    40mF
    60mF
    Temperature (℃) -40℃~1000℃ ±(1.5%+5)
    Frequency (Hz) 10Hz~10MHz
    Features
    Display count 4000
    Auto range
    Jaw opening 28mm
    True RMS
    NCV
    Live wire test
    Continuity test
    Diode
    MAX/MIN
    Relative mode
    Zero mode
    Data hold
    Low battery indication
    Auto power off
    General Characterisitics
    Power 1.5V battery (R03) x 2
    Display 37mm x 25mm
    Product color Red and grey
    Product net weight 248g
    Product size 215mm x 63mm x 36mm
    Standard accessories Batteries, test leads, Themocouple
    Standard individual packing Gift box, Carring bag, English manual
    Standard quantity per carton 40pcs
    Standard carton measurement 485mm x 295mm x 385mm
    Standard carton gross weight 17.8kg
    SKU: n/a
  • UT262A Non-Contact Phase Detector

    0 out of 5
    (0)

    UT262 series adopts clamp type non-contact measuring method, which means user doesn’t need to get in touch with high-voltage exposed wires. It can start detection after three super-induction and high-insulation clamps clamp the exterior of the three-phase wires, which is safer, more practical, and more effective. Beside phase sequence detection, UT262 series can be also used for live wire detection, simple electrical inspection, phase identification, missing-phase judgment, and wire breaker searching. It is a perfect tool for phase sequence detection, motor mounting, and wires maintenance.

    SKU: 22000
  • TND 2000VA

    0 out of 5
    (0)

    Input Voltage=140-250
    Output Voltage=220
    Copper Wind
    Analog Display
    Under and Over Volt Indication
    Under Volt Protection
    Dual Output Socket 110/220

    SKU: n/a