Universal clamp meter, enabling the maintenance of current measurements up to 2000 A, with the diameter of the clamp as 57 mm, and bus bar to 70 * 18 mm
The instrument has an electronic overload protection of all functions and ranges.
CMP-2000 Digital clamp-on multimeter
5 in stock
It provides:
- AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
- Measurement of INRUSH current in start-up phase of electrical device.
- AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
- Resistance measurement and continuity test:
– continuity test with acoustic signalling (beeper) for resistance below 30 Ω. - Capacitance measurement.
- Temperature measurement (Fahrenheit or Celsius).
- Frequency measurement.
- Duty cycle measurement.
- Diode test.
₨61,859 ₨65,809
5 in stock
CompareWeight | 0.6 kg |
---|---|
Dimensions | 28 × 11 × 5 cm |
AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
Measurement of INRUSH current in start-up phase of electrical device.
AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
Resistance measurement and continuity test:
- continuity test with acoustic signalling (beeper) for resistance below 30 Ω.
Capacitance measurement
Temperature measurement (Fahrenheit or Celsius).
Frequency measurement.
Duty cycle measurement.
Diode test.
Additionally:
- safe, insulated measuring clamp,
- autoranging,
- „DATA HOLD” function, for holding measured values,
- backlit LCD,
- „DC ZERO” mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored „zero” value,
- „MAX/MIN” function,
- over range indication,
- „AUTO-OFF” function after 30 min.
Electric security:
- measurement category: CAT IV 600 V acc. to EN 61010 – 1,
- protection class acc. to EN 60529: IP20,
Other technical data:
- power supply, 9 V battery type 6LR61,
- display: 6600 counts, backlit LCD,
- continuity test: threshold 30 Ω,
- diode test: test current of 0,8 mA , typical open circuit voltage 3,2 V DC, typical,
- low battery indication: BAT displayed,
- over range indication: ‘OL’ displayed,
- temperature sensor: type K thermocouple,
- input impedance: ca.10 MΩ (V DC and V AC),
- AC bandwidth: 50…500 Hz,
- auto power OFF: 30 minutes,
- dimensions: 281 x 108 x 53 mm,
- weight: 570 g (with battery),
- accordance with following standards: EN 61010 – 1, EN 61010 – 2-032.
Rated operational conditions:
- able to open the clamp: Ø 57 mm wire 70 x 18 mm bus bar,
- operating temperature: 0…+50 °C,
- storage temperature: -20…+60 °C,
- operating altitude: max 2000 m.
DC current measurement
Range | Resolution | Accuracy |
0,0…659,9 A | 0,1 A | ±(2,0% m.v. + 5 digits) |
660…2000 A | 1 A | ±(3,0% m.v. + 5 digits) for 660…1000 A |
±(5,0% m.v. + 5 digits) for 1000…2000 A |
AC current measurement (TRUE RMS)
Range | Resolution | Accuracy |
0,0…659,9 A | 0,1 A | ±(2,0% m.v. + 10 digits) for 50…60 Hz |
±(3,0% m.v. + 10 digits) for 61…400 Hz | ||
660…1500 A | 1 A | ±(2,5% m.v. + 10 digits) for 50…60 Hz i 660…1000 A |
±(3,5% m.v. + 10 digits) for 61…400 Hz and 660…1000 A |
||
±(5,0% m.v. + 10 digits) for 50…400 Hz and 1000…1500 |
DC voltage measurement
Range | Resolution | Accuracy |
0,000…6,599 V | 0,001 V | ±(0,5% m.v. + 2 digits) |
6,60…65,99 V | 0,01 V | |
66,0…659,9 V | 0,1 V | |
660…1000 V | 1 V |
AC voltage measurement (true RMS)
Range | Resolution | Accuracy |
0,000…6,599 V | 0,001 V | ±(1,5% m.v. + 8 digits) for 50…500 Hz |
6,60…65,99 V | 0,01 V | |
66,0…659,9 V | 0,1 V | |
660…750 V | 1 |
Resistance measurement
Range | Resolution | Accuracy |
0,0…659,9 Ω | 0,1 Ω | ±(1,0% m.v. + 5 digits) |
0,660…6,599 kΩ | 0,001 kΩ | |
6,60…65,99 kΩ | 0,01 kΩ | |
66,0…659,9 kΩ | 0,1 kΩ | |
0,660…6,599 MΩ | 0,001 MΩ | ±(2,0% m.v. + 5 digits) |
6,60…66,00 MΩ | 0,01 MΩ | ±(3,5% m.v. + 5 digits) |
Capacitance measurement
Range | Resolution | Accuracy |
0,0…6,599 nF | 0,001 nF | ±(3,0% m.v. + 30 digits) |
6,60…65,99 nF | 0,01 nF | ±(3,0% m.v. + 10 digits) |
66,0…559,9 nF | 0,1 nF | ±(3,0% m.v. + 30 digits) |
6,600…59,999 µF | 0,001 µF | ±(3,0% m.v. + 10 digits) |
66,00…659,99 µF | 0,01 µF | |
660…659,999 µF | 0,100 µF | |
0,660…6,600 mF | 0,001 mF |
Frequency measurement
Range | Resolution | Accuracy |
10…65,99 Hz | 0,01 Hz | ±(0,1% m.v. + 5 digits) |
66,0…659,9 Hz | 0,1 Hz | |
0,660…6,599 kHz | 0,001 kHz | |
6,60…65,99 kHz | 0,01 kHz | |
66,0…659,9 kHz | 0,1 kHz | |
0,660…1,000 MHz | 0,001 MHz |
Temperature measurement
Range | Resolution | Accuracy |
-20…0°C | 1°C | ±(2,0% m.v. + 3°C) |
0…399°C | ±(1,0% m.v. + 2°C) | |
400…1000°C | ±(2,0% m.v. + 3°C) | |
-4…31°F | 1°F | ±(2,0% m.v. + 6°F) |
32..749°F | ±(1,0% m.v. + 4°F) | |
750…1832°F | ±(2,0% m.v. + 6°F) |
Duty cycle measurement
ange | Resolution | Accuracy |
5…95% | 0,1% | ±(2,0% m.v. + 10 digits) |
„m.v.”- measured value
Based on 0 reviews
Be the first to review “CMP-2000 Digital clamp-on multimeter”
-
LCR Meter
UT612 LCR Meters
UT610 series is a handheld LCR digitalelectric bridge meter with stable performance, safety, reliability and autorange. It is professional to measure inductance, capacitance and resistance. Ithas the features of low power dissipation, high accuracy and fast speed. It canselect the series-parallel measurement mode; measure the quality factor ofcomponents, the loss, the phase angle, equivalent resistance and DC resistance.It can provide up to 5 kinds of frequency under the inductance, capacitance andresistance mode to satisfy the actual requirement.
It is applicable to measuring and filtratingthe inductance, capacitance and resistance of lab, production line, maintenancepoint and teaching. It is the ideal tool of maintaining for many users.
SKU: n/a -
Insulation Tester
DIGITAL INSULATION / CONTINUITY TESTER MODEL 3007A
• Bargraph to display insulation resistance.
• Displays the value of external AC voltage along with flashing symbol.
• Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
• Trac-Lok mode to conserve battery life on insulation and continuity tests.
• Live circuit warning beeper.
• Releasing the test button automatically discharges the charges stored in the circuit under test.
• Backlight function to view the test results in dimly lit areas.
• 200mA continuity measuring current to IEC 61557.
• Minimum 1mA current on insulation tests to IEC 61557.SKU: n/a
There are no reviews yet.