-18%

CMM-10 Multimeter

Availability:

5 in stock


  • Autoranging/manual range selection.
  • DATA HOLD function, for holding measured values.
  • REL function, which allows you to make measurements relative to a stored reference value.
  • Continuity test with acoustic signalling (beeper).
  • AUTO-OFF function.
  • Display 3 7/8 digits (5000 max).

11,844 14,478

5 in stock

Compare

The most important features of CMM-10 are:

  • Autoranging/manual range selection.
  • DATA HOLD function, for holding measured values.
  • REL function, which allows you to make measurements relative to a stored reference value.
  • Continuity test with acoustic signalling (beeper).
  • AUTO-OFF function.
  • Display 3 7/8 digits (5000 max).
Category:
Weight 0.2 kg
Dimensions 14 × 7 × 4 cm

Frequency measurement

Range Resolution Accuracy
5,000 Hz 0,001 Hz ±(1,5% m.v. + 5 digits)
50,00 Hz 0,01 Hz
500,0 Hz 0,1 Hz ±(1,2% m.v. + 3 digits)
5,000 kHz 0,001 kHz
50,00 kHz 0,01 kHz
500,0 kHz 0,1 kHz
5,000 MHz 0,001 MHz ±(1,5% m.v. + 4 digits)
10,00 MHz 0,01 MHz
  • sensitivity: ≥8 V RMS

Duty cycle measurement

Range Resolution Accuracy
0,1…99,9% 0,1% ±(1,2% m.v. + 2 digits)
  • sensitivity: ≥8 V RMS,
  • pulse width: 100µs – 100 ms,
  • frequency width: 5 Hz…150 kHz.

Temperature measurement

Range Resolution Accuracy*
-20°C…+760°C 1°C ±(3% m.v. + 5°C, 9°F)
-4°F…+1400°F 1°F

*) probe (K type) accuracy not included

DC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(0,5% m.v. + 2 digits)
4,000 V 0,001 V ±(1,2% m.v. + 2 digits)
40,00 V 0,01 V ±(1,2% m.v. + 2 digits)
400,0 V 0,1 V
600 V 1 V ±(1,5% m.v. + 2 digits)
  • input impedance: 7,8 MΩ

AC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(1,5% m.v. + 70 digits)
4,000 V 0,001 V ±(1,2% m.v. + 3 digits)
40,00 V 0,01 V ±(1,5% m.v. + 3 digits)
400,0 V 0,1 V
600 V 1 V ±(2,0% m.v. + 4 digits)
  • input impedance: 7,8 MΩ,
  • frequency range: 50…400 Hz.

DC current measurement

Range Resolution Accuracy
400,0 μA 0,1 μA ±(1,0% m.v. + 3 digits)
4 000 μA 1 μA ±(1,5% m.v. + 3 digits)
40,00 mA 0,01 mA
400,0 mA 0,1 mA
4,000 A 0,001 A ±(2,5% m.v. + 5 digits)
10,00 A 0,01 A

AC current measurement

Range Resolution Accuracy
400,0 μA 0,1 μA ±(1,5% m.v. + 5 digits)
4 000 μA 1 μA ±(1,8% m.v. + 5 digits)
40,00 mA 0,01 mA
400,0 mA 0,1 mA
4,000 A 0,001 A ±(3,0% m.v. + 7 digitgs)
10,00 A 0,01 A
  • frequency range: 50…400 Hz.

Resistance measurement

Range Resolution Accuracy
400,0 Ω 0,1 Ω ±(1,2% m.v. + 4 digits)
4,000 kΩ 0,001 kΩ ±(1,0% m.v. + 2 digits)
40,00 kΩ 0,01 kΩ ±(1,2% m.v. + 2 digits)
400,0 kΩ 0,1 kΩ
4,000 MΩ 0,001 MΩ
40,00 MΩ 0,01 MΩ ±(2,0% m.v. + 3 digits)

Capacitance measurement

Range Resolution Accuracy
40,00 nF 0,01 nF ±(5,0% m.v. + 7 digits)
400,0 nF 0,1 nF ±(3,0% m.v. + 5 digits)
4,000 μF 0,001 μF
40,00 μF 0,01 μF
100,0 μF 0,1 μF ±(5,0% m.v. + 5 digits)

“m.v” = measured value

Electric security:

  • type of insulation: double, according to EN 61010 – 1 and IEC 61557
  • measurement category: CAT II 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

Other technical data:

  • power supply: 9 V battery type 6LR61
  • diode test: I=0,3 mA, U0 = 1,5 V DC
  • continuity test: I<0,3 mA, sound signal for R<50 Ω
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • input impedance: 7,8 MΩ (V AC/DC)
  • display: 5000 counts LCD display with function indication
  • dimensions: 138 x 68 x 37 mm
  • weight: approx. 210 g
  • fuses: mA, µA range: 0,5 A/250 V fast; A range: 10 A/250 V fast
  • auto power OFF: 30 min.
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032

Rated operational conditions:

  • operating temperature: 0…+50°C at <70% rel. humidity
  • storage temperature: -20…+60°C at <80% rel. humidity

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMM-10 Multimeter”

There are no reviews yet.

  • UT230B-EU Power Socket

    0 out of 5
    (0)
    SKU: n/a
  • CLAMP METER AC BM 5268

    0 out of 5
    (0)
    BM5268 AC Digital Clamp meter Technical parameters
    Functions Range Accuracy
    BM5268
      DC  Voltage   400mV/4V/40V/400V/600V ±(0.8%+2)
      AC  Voltage   4/40/400/600V ±(1.2%+5)
      AC  Current   4/40/400/600A ±(2%+10)
      Ω  Resistance   400/4K/40K/400K/4M/40MΩ ±(1%+3)
      Capacitance   10n/100n/1μ/10μ/100μ/1m/10mF ±(3%+5)
       Frequency   10/100/1K/10K/100K/1M/30MHz ±(0.5%+3)
       ºC/ºF   -50ºC~1000ºC ±(1%+5)
       -58ºF~1832ºF ±(1.2%+6)
      Functions Range Accuracy
      True RMS
      Manual range
      Automatic range
      Auto power OFF About  10minutes
    Auto power OFF/Manually turn it off
      Diode Test
      VHZ      voltage measuring frequency
    Phase line recognition
      Continuity Testing
      Data hold
      INR Surge voltage
      low Battery indication
      Overload protection
    Greatest display 1999
      Jaw Size Φ30mm
            General Features
      Power                                     DC9V(6F22)Battery
      Color Gray+Red
      Weight About 220g
     Size 195×64×35mm
      Standard accessories Multimeter leads+Batteries+Temperature Sensor
      Standard Pack Color Box,User Manua
      Safety rating EN61010-1,CAT.II 600V

     

     

    SKU: n/a
  • LKZ-1000 Wires and pipe locator

    0 out of 5
    (0)
    • Passive or active modes of tracing.
    • Detection of underground live wires.
    • Detection of underground wires with no voltage (radio mode).
    • Detection of underground wires with no voltage using a transmitter (galvanised, inductive or clamp-based connection).
    • Tracing metallic or non-conductive pipes using an additional probe.
    • Tracing non-conductive pipelines using a “floating” probe.
    • Tracing a determined cable.
    • Determining the depth of a cable.
    SKU: n/a
  • MC TIP 900M TFS

    0 out of 5
    (0)
    SKU: n/a
  • YH 950 IRON FOR YH 950

    0 out of 5
    (0)
    SKU: n/a