Industrial multimeter CMM-40 was designed for the purpose of measurements of AC/DC voltage, AC/DC current, resistance, capacitance, frequency (electrical and electronic), duty cycle, temperature and also for testing diodes and continuity.
CMM-40 Industrial Multimeter
5 in stock
The most important features of CMM-40 are:
- autoranging/manual range selection,
- „DATA HOLD” function, for holding measured values,
- „REL” function, which allows you to make measurements relative to a stored reference value,
- „MAX/MIN” function,
- „PEAK HOLD” function,
- memory for 2000 measurement resultS,
- continuity test with acoustic signalling (beeper),
- „AUTO-OFF” function,
- display 4¾ digits (40000 max),
- double molded, waterproof casing.
₨30,270 ₨34,221
5 in stock
CompareWeight | 0.4 kg |
---|---|
Dimensions | 19 × 8 × 5 cm |
Frequency measurement (electronic)
Range | Resolution | Accuracy |
40,000 Hz | 0,001 Hz | ±(0,1% m.v. + 1 digit) |
400,00 Hz | 0,01 Hz | |
4,0000 kHz | 0,0001 kHz | |
40,000 kHz | 0,001 kHz | |
400,00 kHz | 0,01 kHz | |
4,0000 MHz | 0,0001 MHz | |
40,000 MHz | 0,001 MHz | |
100,00 MHz | 0,01 MHz | not speccified |
- Sensitivity: 0.8 V rms min. @ 20% to 80% duty cycle and <100 kHz; 5 V rms min @ 20% to 80% duty cycle and > 100 kHz
Frequency measurement (electrical)
Range | Resolution | Accuracy |
40,00 Hz…10,000 kHz | 0,01 Hz…0,001 kHz | ± 0,5% m.v. |
- sensitivity: 1 V rms
Duty cycle measurement
Range | Resolution | Accuracy |
0,10…99,00% | 0,01% | ±(1,2% m.v. + 2 digits) |
- pulse width: 100μs – 100 ms,
- frequency width: 5 Hz…150 kHz.
Temperature measurement
Range | Resolution | Accuracy |
-50,0°C…+1200,0°C | 0,1°C | ±(1% m.v. + 2,5°C) |
-58,0°F…+2192,0°F | 0,1°F | ±(1% m.v. + 4,5°F) |
DC voltage measurement
Range | Resolution | Accuracy |
400,0 mV | 0,01 mV | ±(0,06% m.v. + 4 digits) |
4,0000 V | 0,0001 V | |
40,000 V | 0,001 V | |
400,00 V | 0,01 V | |
1000,0 V | 0,1 V | ±(0,1% w.m. + 5 cyfr) |
AC voltage measurement (True RMS)
Range | Resolution | Accuracy |
400,00 mV | 0,01 mV | ±(1% m.v. + 40 digits) |
4,0000 V | 0,0001 V | ±(1% m.v. + 30 digits) |
40,000 V | 0,001 V | |
400,00 V | 0,01 V | |
1000,0 V | 0,1 V |
- frequency range: 50…1000 Hz.
AC/DC current measurement (True RMS)
Range | Resolution | Accuracy |
400,00 μA | 0,01 μA | dla DC ±(1,0% m.v. + 3 digits)
dla AC ±(1,5% m.v. + 30 digits) |
4 000,0 μA | 0,1 μA | |
40,000 mA | 0,001 mA | |
400,00 mA | 0,01 mA | |
10,000 A | 0,001 A |
- 20 A: 30 sec max with reduced accuracy.
Resistance measurement
Range | Resolution | Accuracy |
400,00 Ω | 0,01 Ω | ±(0,3% m.v. + 9 digits) |
4,0000 kΩ | 0,0001 kΩ | ±(0,3% m.v. + 4 digits) |
40,000 kΩ | 0,001 kΩ | |
400,00 kΩ | 0,01 kΩ | |
4,0000 MΩ | 0,0001 MΩ | |
40,000 MΩ | 0,001 MΩ | ±(2,0% m.v. + 10 digits) |
Capacitance measurement
Range | Resolution | Accuracy |
40,000 nF | 0,001 nF | ±(3,5% m.v. + 40 digits) |
400,00 nF | 0,01 nF | |
4,0000 μF | 0,0001 μF | ±(3,5% m.v. + 10 digits) |
40,000 μF | 0,001 μF | |
400,00 μF | 0,01 μF | |
4000,0 μF | 0,1 μF | ±(5% m.v. + 10 digits) |
40,000 mF | 0,001 mF |
Other technical data:
- power supply: 9 V battery type 6LR61
- diode test: I=0,9 mA, U0 = 2,8 V DC
- continuity test: I<0,35 mA, sound signal for R<35 Ω
- over range indication: 0L displayed
- crest factor: ≤ 3 at full scale up to 500 V; decreasing linearly to ≤ 1,5 at 1000 V
- PEAK: captures peaks >1 ms
- sampling rate: 2 times per second
- input impedance: 10 MΩ (V DC), 9 MΩ (V AC)
- display: 40000 counts backlit LCD with bargraph, 4¾ digits
- store capacitance: 2000
- dimensions: 187 x 81 x 55 mm
- weight: 342 g
- fuses: mA, µA range: 0,5 A/1000 V ceramic fast blow; A range: 10 A/1000 V ceramic fast blow
- auto power OFF: 15 min.
- accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
Electric security:
- type of insulation: double, according to EN 61010 – 1 and IEC 61557
- measurement category: CAT III 1000 V acc. to EN 61010 – 1:2004
- protection class acc. to EN 60529: IP67
Rated operational conditions:
- operating temperature: 0…+40°C
- storage temperature: -20…+60°C
- operating humidity: max 80% up to 87°F (31°C); decreasing linearly to 50% at 104°F (40°C)
- operating altitude: max 2000 m
„m.v.”- measured value
Based on 0 reviews
Be the first to review “CMM-40 Industrial Multimeter”
-
Environment Meters
UT383 – Mini Light Meter
UT383 is a mini light meter equipped with photoelectric sensing technology, which can effectively represent light intensity with electrical signals, then processes data and displays the result on LCD. It is light weight, compact, ergonomic, and user friendly, making it a great tool for monitoring light intensity in homes, offices, schools, laboratories, indoor farming, hospitals, and other areas.
SKU: n/a -
Clamp Meters
UT207B 1000A True RMS Digital Clamp Meter
1. Flashlight button: Short press thisbutton to turn on/off the flashlight.
2. Flexible current probe (optional) to extendthe AC current measurement range to3000A
3. Inrush current capture
4. NCV Multi-Segment Display and audio/visual alarm
5. True RMS/Auto backlight
6. NCV/Function retentionSKU: n/a -
Analog Multimeters
ANALOG METER DE 960
Features Of YX-960 TR Handheld Analog Multimeter:
- Excellent DC resolution factor of 2mV.
- Expanded resistance measurement from 020 to 200M.
- Series capacitor DC to enable measurement of only AC components.
- A large and bright meteor with a scale length of 80mm.
- The sensitivity of 44pA at full scale.
- Fuse and diode protection.
- Measures hFE of transistor directly.
SKU: n/a