Industrial multimeter CMM-40 was designed for the purpose of measurements of AC/DC voltage, AC/DC current, resistance, capacitance, frequency (electrical and electronic), duty cycle, temperature and also for testing diodes and continuity.
CMM-40 Industrial Multimeter
5 in stock
The most important features of CMM-40 are:
- autoranging/manual range selection,
- „DATA HOLD” function, for holding measured values,
- „REL” function, which allows you to make measurements relative to a stored reference value,
- „MAX/MIN” function,
- „PEAK HOLD” function,
- memory for 2000 measurement resultS,
- continuity test with acoustic signalling (beeper),
- „AUTO-OFF” function,
- display 4¾ digits (40000 max),
- double molded, waterproof casing.
₨30,270 ₨34,221
5 in stock
CompareWeight | 0.4 kg |
---|---|
Dimensions | 19 × 8 × 5 cm |
Frequency measurement (electronic)
Range | Resolution | Accuracy |
40,000 Hz | 0,001 Hz | ±(0,1% m.v. + 1 digit) |
400,00 Hz | 0,01 Hz | |
4,0000 kHz | 0,0001 kHz | |
40,000 kHz | 0,001 kHz | |
400,00 kHz | 0,01 kHz | |
4,0000 MHz | 0,0001 MHz | |
40,000 MHz | 0,001 MHz | |
100,00 MHz | 0,01 MHz | not speccified |
- Sensitivity: 0.8 V rms min. @ 20% to 80% duty cycle and <100 kHz; 5 V rms min @ 20% to 80% duty cycle and > 100 kHz
Frequency measurement (electrical)
Range | Resolution | Accuracy |
40,00 Hz…10,000 kHz | 0,01 Hz…0,001 kHz | ± 0,5% m.v. |
- sensitivity: 1 V rms
Duty cycle measurement
Range | Resolution | Accuracy |
0,10…99,00% | 0,01% | ±(1,2% m.v. + 2 digits) |
- pulse width: 100μs – 100 ms,
- frequency width: 5 Hz…150 kHz.
Temperature measurement
Range | Resolution | Accuracy |
-50,0°C…+1200,0°C | 0,1°C | ±(1% m.v. + 2,5°C) |
-58,0°F…+2192,0°F | 0,1°F | ±(1% m.v. + 4,5°F) |
DC voltage measurement
Range | Resolution | Accuracy |
400,0 mV | 0,01 mV | ±(0,06% m.v. + 4 digits) |
4,0000 V | 0,0001 V | |
40,000 V | 0,001 V | |
400,00 V | 0,01 V | |
1000,0 V | 0,1 V | ±(0,1% w.m. + 5 cyfr) |
AC voltage measurement (True RMS)
Range | Resolution | Accuracy |
400,00 mV | 0,01 mV | ±(1% m.v. + 40 digits) |
4,0000 V | 0,0001 V | ±(1% m.v. + 30 digits) |
40,000 V | 0,001 V | |
400,00 V | 0,01 V | |
1000,0 V | 0,1 V |
- frequency range: 50…1000 Hz.
AC/DC current measurement (True RMS)
Range | Resolution | Accuracy |
400,00 μA | 0,01 μA | dla DC ±(1,0% m.v. + 3 digits)
dla AC ±(1,5% m.v. + 30 digits) |
4 000,0 μA | 0,1 μA | |
40,000 mA | 0,001 mA | |
400,00 mA | 0,01 mA | |
10,000 A | 0,001 A |
- 20 A: 30 sec max with reduced accuracy.
Resistance measurement
Range | Resolution | Accuracy |
400,00 Ω | 0,01 Ω | ±(0,3% m.v. + 9 digits) |
4,0000 kΩ | 0,0001 kΩ | ±(0,3% m.v. + 4 digits) |
40,000 kΩ | 0,001 kΩ | |
400,00 kΩ | 0,01 kΩ | |
4,0000 MΩ | 0,0001 MΩ | |
40,000 MΩ | 0,001 MΩ | ±(2,0% m.v. + 10 digits) |
Capacitance measurement
Range | Resolution | Accuracy |
40,000 nF | 0,001 nF | ±(3,5% m.v. + 40 digits) |
400,00 nF | 0,01 nF | |
4,0000 μF | 0,0001 μF | ±(3,5% m.v. + 10 digits) |
40,000 μF | 0,001 μF | |
400,00 μF | 0,01 μF | |
4000,0 μF | 0,1 μF | ±(5% m.v. + 10 digits) |
40,000 mF | 0,001 mF |
Other technical data:
- power supply: 9 V battery type 6LR61
- diode test: I=0,9 mA, U0 = 2,8 V DC
- continuity test: I<0,35 mA, sound signal for R<35 Ω
- over range indication: 0L displayed
- crest factor: ≤ 3 at full scale up to 500 V; decreasing linearly to ≤ 1,5 at 1000 V
- PEAK: captures peaks >1 ms
- sampling rate: 2 times per second
- input impedance: 10 MΩ (V DC), 9 MΩ (V AC)
- display: 40000 counts backlit LCD with bargraph, 4¾ digits
- store capacitance: 2000
- dimensions: 187 x 81 x 55 mm
- weight: 342 g
- fuses: mA, µA range: 0,5 A/1000 V ceramic fast blow; A range: 10 A/1000 V ceramic fast blow
- auto power OFF: 15 min.
- accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
Electric security:
- type of insulation: double, according to EN 61010 – 1 and IEC 61557
- measurement category: CAT III 1000 V acc. to EN 61010 – 1:2004
- protection class acc. to EN 60529: IP67
Rated operational conditions:
- operating temperature: 0…+40°C
- storage temperature: -20…+60°C
- operating humidity: max 80% up to 87°F (31°C); decreasing linearly to 50% at 104°F (40°C)
- operating altitude: max 2000 m
„m.v.”- measured value
Based on 0 reviews
Be the first to review “CMM-40 Industrial Multimeter”
-
Phase Detector Meters
UT262A Non-Contact Phase Detector
UT262 series adopts clamp type non-contact measuring method, which means user doesn’t need to get in touch with high-voltage exposed wires. It can start detection after three super-induction and high-insulation clamps clamp the exterior of the three-phase wires, which is safer, more practical, and more effective. Beside phase sequence detection, UT262 series can be also used for live wire detection, simple electrical inspection, phase identification, missing-phase judgment, and wire breaker searching. It is a perfect tool for phase sequence detection, motor mounting, and wires maintenance.
SKU: 22000 -
Analog Multimeters
ANALOG METER YX 360TR BS
Features Of Handheld YX-360TRE-B Analog Meter Voltmeter:
- High accuracy analogue multimeter for general purposes.
- Mirrored needle indicator with an accurate reading.
- Check both AC and DC parameters with continuity buzzer on Ohms.
- Up to 1000V on both AC and DC Voltage.
- 19 versatile ranges for general-purpose testing.
- Fuse & Diode protection.
- Compact sizing.
- Tilt back-stand.
- The large and mirrored scale of 80mm length.
SKU: n/a -
Clamp Meters
CMP-1006 Digital Clamp-on multimeter
Additionally:
- safe, insulated measuring clamps,
- autoranging/manual range selection,
- DATA HOLD function, for holding measured values,
- backlit LCD,
- DC ZERO mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored zero value,
- MAX/MIN function,
- over range indication,
- AUTO-OFF function.
SKU: n/a -
-
Dc Veriable Loads
UNI-T UTL8211/UTL8212 High-Precision Compact DC Electronic Load Tester Single/Dual Channel 150V Power Supply Current Test – UTL8211
Dc Veriable LoadsUNI-T UTL8211/UTL8212 High-Precision Compact DC Electronic Load Tester Single/Dual Channel 150V Power Supply Current Test – UTL8211
Application:
Power supply test, adapter/charger test, battery test, lithium battery protection board test, ATE, component test, etc., commonly used in home appliance manufacturers, LCD and other computer component manufacturers, switching power supply and LED manufacturers, adapter charger manufacturers and other companies Production and testing use
SKU: n/a
There are no reviews yet.