Universal clamp meter, enabling the maintenance of current measurements up to 2000 A, with the diameter of the clamp as 57 mm, and bus bar to 70 * 18 mm
The instrument has an electronic overload protection of all functions and ranges.
CMP-2000 Digital clamp-on multimeter
5 in stock
It provides:
- AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
- Measurement of INRUSH current in start-up phase of electrical device.
- AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
- Resistance measurement and continuity test:
– continuity test with acoustic signalling (beeper) for resistance below 30 Ω. - Capacitance measurement.
- Temperature measurement (Fahrenheit or Celsius).
- Frequency measurement.
- Duty cycle measurement.
- Diode test.
₨61,859 ₨65,809
5 in stock
CompareWeight | 0.6 kg |
---|---|
Dimensions | 28 × 11 × 5 cm |
AC current measurement (TRUE RMS) up to 1500 A and DC up to 2000 A.
Measurement of INRUSH current in start-up phase of electrical device.
AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1000 V.
Resistance measurement and continuity test:
- continuity test with acoustic signalling (beeper) for resistance below 30 Ω.
Capacitance measurement
Temperature measurement (Fahrenheit or Celsius).
Frequency measurement.
Duty cycle measurement.
Diode test.
Additionally:
- safe, insulated measuring clamp,
- autoranging,
- „DATA HOLD” function, for holding measured values,
- backlit LCD,
- „DC ZERO” mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored „zero” value,
- „MAX/MIN” function,
- over range indication,
- „AUTO-OFF” function after 30 min.
Electric security:
- measurement category: CAT IV 600 V acc. to EN 61010 – 1,
- protection class acc. to EN 60529: IP20,
Other technical data:
- power supply, 9 V battery type 6LR61,
- display: 6600 counts, backlit LCD,
- continuity test: threshold 30 Ω,
- diode test: test current of 0,8 mA , typical open circuit voltage 3,2 V DC, typical,
- low battery indication: BAT displayed,
- over range indication: ‘OL’ displayed,
- temperature sensor: type K thermocouple,
- input impedance: ca.10 MΩ (V DC and V AC),
- AC bandwidth: 50…500 Hz,
- auto power OFF: 30 minutes,
- dimensions: 281 x 108 x 53 mm,
- weight: 570 g (with battery),
- accordance with following standards: EN 61010 – 1, EN 61010 – 2-032.
Rated operational conditions:
- able to open the clamp: Ø 57 mm wire 70 x 18 mm bus bar,
- operating temperature: 0…+50 °C,
- storage temperature: -20…+60 °C,
- operating altitude: max 2000 m.
DC current measurement
Range | Resolution | Accuracy |
0,0…659,9 A | 0,1 A | ±(2,0% m.v. + 5 digits) |
660…2000 A | 1 A | ±(3,0% m.v. + 5 digits) for 660…1000 A |
±(5,0% m.v. + 5 digits) for 1000…2000 A |
AC current measurement (TRUE RMS)
Range | Resolution | Accuracy |
0,0…659,9 A | 0,1 A | ±(2,0% m.v. + 10 digits) for 50…60 Hz |
±(3,0% m.v. + 10 digits) for 61…400 Hz | ||
660…1500 A | 1 A | ±(2,5% m.v. + 10 digits) for 50…60 Hz i 660…1000 A |
±(3,5% m.v. + 10 digits) for 61…400 Hz and 660…1000 A |
||
±(5,0% m.v. + 10 digits) for 50…400 Hz and 1000…1500 |
DC voltage measurement
Range | Resolution | Accuracy |
0,000…6,599 V | 0,001 V | ±(0,5% m.v. + 2 digits) |
6,60…65,99 V | 0,01 V | |
66,0…659,9 V | 0,1 V | |
660…1000 V | 1 V |
AC voltage measurement (true RMS)
Range | Resolution | Accuracy |
0,000…6,599 V | 0,001 V | ±(1,5% m.v. + 8 digits) for 50…500 Hz |
6,60…65,99 V | 0,01 V | |
66,0…659,9 V | 0,1 V | |
660…750 V | 1 |
Resistance measurement
Range | Resolution | Accuracy |
0,0…659,9 Ω | 0,1 Ω | ±(1,0% m.v. + 5 digits) |
0,660…6,599 kΩ | 0,001 kΩ | |
6,60…65,99 kΩ | 0,01 kΩ | |
66,0…659,9 kΩ | 0,1 kΩ | |
0,660…6,599 MΩ | 0,001 MΩ | ±(2,0% m.v. + 5 digits) |
6,60…66,00 MΩ | 0,01 MΩ | ±(3,5% m.v. + 5 digits) |
Capacitance measurement
Range | Resolution | Accuracy |
0,0…6,599 nF | 0,001 nF | ±(3,0% m.v. + 30 digits) |
6,60…65,99 nF | 0,01 nF | ±(3,0% m.v. + 10 digits) |
66,0…559,9 nF | 0,1 nF | ±(3,0% m.v. + 30 digits) |
6,600…59,999 µF | 0,001 µF | ±(3,0% m.v. + 10 digits) |
66,00…659,99 µF | 0,01 µF | |
660…659,999 µF | 0,100 µF | |
0,660…6,600 mF | 0,001 mF |
Frequency measurement
Range | Resolution | Accuracy |
10…65,99 Hz | 0,01 Hz | ±(0,1% m.v. + 5 digits) |
66,0…659,9 Hz | 0,1 Hz | |
0,660…6,599 kHz | 0,001 kHz | |
6,60…65,99 kHz | 0,01 kHz | |
66,0…659,9 kHz | 0,1 kHz | |
0,660…1,000 MHz | 0,001 MHz |
Temperature measurement
Range | Resolution | Accuracy |
-20…0°C | 1°C | ±(2,0% m.v. + 3°C) |
0…399°C | ±(1,0% m.v. + 2°C) | |
400…1000°C | ±(2,0% m.v. + 3°C) | |
-4…31°F | 1°F | ±(2,0% m.v. + 6°F) |
32..749°F | ±(1,0% m.v. + 4°F) | |
750…1832°F | ±(2,0% m.v. + 6°F) |
Duty cycle measurement
ange | Resolution | Accuracy |
5…95% | 0,1% | ±(2,0% m.v. + 10 digits) |
„m.v.”- measured value
Based on 0 reviews
Be the first to review “CMP-2000 Digital clamp-on multimeter”
-
Multimeters
UT890D Digital Multimeter
Product Features 1. 6000 Counts 2. True RMS voltage and current measurements 3. Capacitance, Resistance, Buzzer, Diode 4. Capacitance with REL function, resolution is 1pF, maximum measurement range is 6000μF 5. Highly accurate frequency measurement function; minimum resolution is 0.001Hz 6. MAX\MIN and MAX-MIN value 7. DC current minimum resolution is 0.01 A, AC current minimum resolution is 1μA, maximum range is 20A 8. HOLD function,backlight and auto power off function
SKU: n/a -
Oscilloscopes
UNI-T MSO3152E 150MHz Mixed Signal 2 Channel Digital Oscilloscope
Analog bandwidth 150MHz 250MHz Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels) Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) Memory depth 70Mpts Waveform capture rate 200,000wfms/s Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display ) Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall] Input impedance (1MΩ±1%) II (20pF±3pF) Input impedance digital (101kΩ±1%) II (9pF±1pF) Vertical scale 1mV/div~20 V/div (1 MΩ) DC gain accuracy <5mV: ±3%, ≥5mV: ±2% Waveform record 100,000 frames Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
CAN, LIN, FlexRayBus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations Auto measurements
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
-Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→AMeasurement display 5 types Measurement statistics Average, Max, Min, standard deviation and number of measurements Frequency counter 6 bits Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA Standard Accessories
USB interface cable UT-D14 Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06 Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05 16CH Logic analyzer probe UT-15M SKU: n/a -
Analog Multimeters
ANALOG MULTIMETER MF 47A
Features:
1. Multifunctional, can measure ac/dc voltage, dc current, resistance, battery test, capacitance, hfe. 2. Buzzer alarm: when it is below 50, it will wake up the alarm. 3. Battery Test: Large measuring range of 1.2-3.6v. 4. Accurate and Reliable: Clear dial, clear measurement results and high efficiency. 5. Audio Level Meter: Designed to measure amplifier gain and transmission losses with given impedant load and the measurement unit is db.
SKU: n/a