-11%

CMP-401 Digital Clamp-on multimeter

Availability:

5 in stock


Additionally:

  • safe, insulated measuring clamps,
  • double molded housing,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • REL function,
  • over range indication,

AUTO-OFF function.

25,664 28,956

5 in stock

Compare

DC current measurement and AC current.
AC/DC voltage measurement up to 600 V.Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 50.

Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Capacitance measurement .
Diode test.

Category:
Weight 0.2 kg
Dimensions 20 × 7 × 4 cm

DC current measurement and AC current. .
AC/DC voltage measurement up to 600 V.

Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 50 Ω.

Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Capacitance measurement 
Diode test.
Additionally:

  • safe, insulated measuring clamps,
  • double molded housing,
  • autoranging/manual range selection,
  • „DATA HOLD” function, for holding measured values,
  • backlit LCD,
  • „REL” function,
  • over range indication,
  • „AUTO-OFF” function.

Electric security:

  • measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

Other technical data:

  • power supply: 9 V battery type 6LR61
  • display: 4000 counts, backlit LCD
  • continuity test: I<0,5 mA, sound signal for R<50 Ω
  • diode test: I = 0,3 mA, U0 = 1,5 V DC
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • input impedance: 10 MΩ (V DC and V AC)
  • clamp size: opening 30 mm (1,2”)
  • auto power OFF: approx. 30 min.
  • dimensions: 197 x 70 x 40 mm
  • weight: 183 g
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
  • quality standard: ISO 9001

Rated operational conditions:

  • operating temperature: 0…+40°C
  • storage temperature: -20…+60°C
  • operating humidity: max 80% up to 31°C; decreasing linearly to 50% at 40°C
  • operating altitude: max 2000 m

 

Temperature measurement

Range Accuracy*
-20,0…760°C ±(3% m.v. + 5°C)
-4,0…1400°F ±(3% m.v. + 9°F)

*probe (K type) accuracy not included

 

Frequency measurement

Range Accuracy
10 Hz … 10 kHz ±(1,5% m.v. + 2 digits)
  • csensitivity: 100 V (<50 Hz), 50 V (50…400 Hz); 15 V (401 Hz…10 kHz)

 

AC current measurement

Range Resolution Accuracy
40,00 A 0,01 A ±(2,5% m.v. + 8 digits)
400,0 A 0,1 A ±(2,8% m.v. + 5 digits)
  • frequency range: 50…60 Hz.

 

DC current measurement

Range Resolution Accuracy
40,00 A 0,01 A ±(2,5% m.v. + 5 digits)
400,0 A 0,1 A ±(2,8% m.v. + 5 digits)

 

AC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(1,5% m.v. + 30 digits)
4,000 V 0,001 V ±(1,5% m.v. + 5 digits)
40,00 V 0,01 V ±(1,5% m.v. + 5 digits)
400,0 V 0,1 V ±(1,5% m.v. + 5 digits)
600,0 V 1 V ±(2% m.v. + 5 digits)
  • frequency range: 50…400 Hz.

 

DC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(0,8% m.v. + 2 digits)
4,000 V 0,001 V ±(1,5% m.v. + 2 digits)
40,00 V 0,01 V ±(1,5% m.v. + 2 digits)
400,0 V 0,1 V ±(1,5% m.v. + 2 digits)
600,0 V 1 V ±(2% m.v. + 2 digits)

 

Resistance measurement

Range Resolution Accuracy
400,0 Ω 0,1 Ω ±(1,0% m.v. + 4 digits)
4,000 kΩ 0,001 kΩ ±(1,5% m.v. + 2 digits)
40,00 kΩ 0,01 kΩ ±(1,5% m.v. + 2 digits)
400,0 kΩ 0,1 kΩ ±(1,5% m.v. + 2 digits)
4,000 MΩ 0,001 MΩ ±(2,5% m.v. + 3 digits)
40,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 digits)

 

Capacitance measurement

Range Resolution Accuracy
40,00 nF 0,01 nF ±(4% m.v. + 20 digits)
400,0 nF 0,1 nF ±(3% m.v. + 5 digits)
4,000 nF 0,001 μF ±(3% m.v. + 5 digits)
40,00 nF 0,01 μF ±(3% m.v. + 5 digits)
100,0 nF 0,1 μF ±(4% m.v. + 10 digits)

„m.v.”- measured value

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-401 Digital Clamp-on multimeter”

There are no reviews yet.

  • UT278A Clamp Earth Ground Testers

    0 out of 5
    (0)

    UT270 series is widely used in earth ground and circuit resistance measurements of electric power, telecommunications, meteorology, oil field, construction and industrial electrical equipment. It can measure the ground system of the circuit without disconnecting grounding wires, auxiliary electrode. UT278A can also measure leakage current and neutralline current of earth ground system
    .

    SKU: n/a
  • PHASE INDICATOR KEW 8031

    0 out of 5
    (0)

    ・Two Functions in One Unit
    Presence of open phase can be checked by the lamps, and the phase
    sequence can be indicated by the rotating disk.

    ・ High Reliability
    measuring range for 3-phase installations from 110V to 600V.
    Sealed against dust ensures the trouble-free performance.

    ・ Battery-free tester

    SKU: n/a
  • UT89XD Digital Multimeter

    0 out of 5
    (0)

    1. 1000V AC/DC; 20A AC/DC

    2. True RMS, 6000 count
    3. Dual range NCV test which quickly identifies neutral and live wires
    through light intensity
    4. LED measurement
    5. Audible/visual alarm
    6. Capacitor charging indicator
    7. Ergonomic design
    8. Double injection molding
    9. 1m drop proof
    10. Flashlight; Auto backlight
    SKU: n/a
  • UT39A+ Digital Multimeter

    0 out of 5
    (0)

    1. 1000V DC voltage measurement

    2. 750V AC voltage measurement
    3. 10A DC/AC current measurement
    4. Resistance/Capacitance
    5. hFE
    6. Diode/Continuity test
    SKU: n/a