-11%

CMP-401 Digital Clamp-on multimeter

Availability:

5 in stock


Additionally:

  • safe, insulated measuring clamps,
  • double molded housing,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • REL function,
  • over range indication,

AUTO-OFF function.

25,664 28,956

5 in stock

Compare

DC current measurement and AC current.
AC/DC voltage measurement up to 600 V.Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 50.

Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Capacitance measurement .
Diode test.

Category:
Weight 0.2 kg
Dimensions 20 × 7 × 4 cm

DC current measurement and AC current. .
AC/DC voltage measurement up to 600 V.

Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 50 Ω.

Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Capacitance measurement 
Diode test.
Additionally:

  • safe, insulated measuring clamps,
  • double molded housing,
  • autoranging/manual range selection,
  • „DATA HOLD” function, for holding measured values,
  • backlit LCD,
  • „REL” function,
  • over range indication,
  • „AUTO-OFF” function.

Electric security:

  • measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

Other technical data:

  • power supply: 9 V battery type 6LR61
  • display: 4000 counts, backlit LCD
  • continuity test: I<0,5 mA, sound signal for R<50 Ω
  • diode test: I = 0,3 mA, U0 = 1,5 V DC
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • input impedance: 10 MΩ (V DC and V AC)
  • clamp size: opening 30 mm (1,2”)
  • auto power OFF: approx. 30 min.
  • dimensions: 197 x 70 x 40 mm
  • weight: 183 g
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
  • quality standard: ISO 9001

Rated operational conditions:

  • operating temperature: 0…+40°C
  • storage temperature: -20…+60°C
  • operating humidity: max 80% up to 31°C; decreasing linearly to 50% at 40°C
  • operating altitude: max 2000 m

 

Temperature measurement

Range Accuracy*
-20,0…760°C ±(3% m.v. + 5°C)
-4,0…1400°F ±(3% m.v. + 9°F)

*probe (K type) accuracy not included

 

Frequency measurement

Range Accuracy
10 Hz … 10 kHz ±(1,5% m.v. + 2 digits)
  • csensitivity: 100 V (<50 Hz), 50 V (50…400 Hz); 15 V (401 Hz…10 kHz)

 

AC current measurement

Range Resolution Accuracy
40,00 A 0,01 A ±(2,5% m.v. + 8 digits)
400,0 A 0,1 A ±(2,8% m.v. + 5 digits)
  • frequency range: 50…60 Hz.

 

DC current measurement

Range Resolution Accuracy
40,00 A 0,01 A ±(2,5% m.v. + 5 digits)
400,0 A 0,1 A ±(2,8% m.v. + 5 digits)

 

AC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(1,5% m.v. + 30 digits)
4,000 V 0,001 V ±(1,5% m.v. + 5 digits)
40,00 V 0,01 V ±(1,5% m.v. + 5 digits)
400,0 V 0,1 V ±(1,5% m.v. + 5 digits)
600,0 V 1 V ±(2% m.v. + 5 digits)
  • frequency range: 50…400 Hz.

 

DC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(0,8% m.v. + 2 digits)
4,000 V 0,001 V ±(1,5% m.v. + 2 digits)
40,00 V 0,01 V ±(1,5% m.v. + 2 digits)
400,0 V 0,1 V ±(1,5% m.v. + 2 digits)
600,0 V 1 V ±(2% m.v. + 2 digits)

 

Resistance measurement

Range Resolution Accuracy
400,0 Ω 0,1 Ω ±(1,0% m.v. + 4 digits)
4,000 kΩ 0,001 kΩ ±(1,5% m.v. + 2 digits)
40,00 kΩ 0,01 kΩ ±(1,5% m.v. + 2 digits)
400,0 kΩ 0,1 kΩ ±(1,5% m.v. + 2 digits)
4,000 MΩ 0,001 MΩ ±(2,5% m.v. + 3 digits)
40,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 digits)

 

Capacitance measurement

Range Resolution Accuracy
40,00 nF 0,01 nF ±(4% m.v. + 20 digits)
400,0 nF 0,1 nF ±(3% m.v. + 5 digits)
4,000 nF 0,001 μF ±(3% m.v. + 5 digits)
40,00 nF 0,01 μF ±(3% m.v. + 5 digits)
100,0 nF 0,1 μF ±(4% m.v. + 10 digits)

„m.v.”- measured value

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-401 Digital Clamp-on multimeter”

There are no reviews yet.

  • CLAMP METER AC BM 5268

    0 out of 5
    (0)
    BM5268 AC Digital Clamp meter Technical parameters
    Functions Range Accuracy
    BM5268
      DC  Voltage   400mV/4V/40V/400V/600V ±(0.8%+2)
      AC  Voltage   4/40/400/600V ±(1.2%+5)
      AC  Current   4/40/400/600A ±(2%+10)
      Ω  Resistance   400/4K/40K/400K/4M/40MΩ ±(1%+3)
      Capacitance   10n/100n/1μ/10μ/100μ/1m/10mF ±(3%+5)
       Frequency   10/100/1K/10K/100K/1M/30MHz ±(0.5%+3)
       ºC/ºF   -50ºC~1000ºC ±(1%+5)
       -58ºF~1832ºF ±(1.2%+6)
      Functions Range Accuracy
      True RMS
      Manual range
      Automatic range
      Auto power OFF About  10minutes
    Auto power OFF/Manually turn it off
      Diode Test
      VHZ      voltage measuring frequency
    Phase line recognition
      Continuity Testing
      Data hold
      INR Surge voltage
      low Battery indication
      Overload protection
    Greatest display 1999
      Jaw Size Φ30mm
            General Features
      Power                                     DC9V(6F22)Battery
      Color Gray+Red
      Weight About 220g
     Size 195×64×35mm
      Standard accessories Multimeter leads+Batteries+Temperature Sensor
      Standard Pack Color Box,User Manua
      Safety rating EN61010-1,CAT.II 600V

     

     

    SKU: n/a
  • UT701 Single Function Temperature Calibrator

    0 out of 5
    (0)
    SKU: n/a